Perfecting performance of distance protective relays and it's associated pilot protection schemes in extra high voltage (EHV) transmission line applications
The fundamentals of protective relaying of EHV transmission lines such as 345 kV is to ensure secure protection for all line s internal faults, and stable operation for all foresee-able external faults during system contingencies. This paper provides an overview of how utilities have traditionally a...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | 19 pp. |
container_title | |
container_volume | |
creator | Lucia, M. Cezari, R. Erwin, D. Theron, J.C. Thakur, M. |
description | The fundamentals of protective relaying of EHV transmission lines such as 345 kV is to ensure secure protection for all line s internal faults, and stable operation for all foresee-able external faults during system contingencies. This paper provides an overview of how utilities have traditionally applied distance protection relays and its associated pilot protection schemes for protecting EHV transmission lines. These traditional methods cover most aspects of the protection and control of EHV lines, however these methods lack in performance when they are subjected to actual power system and fault conditions. This paper highlights the needs in perfecting distance protection relays and its associated pilot protection schemes for EHV transmission lines ensuring reliable performance during all foresee-able system load and fault conditions. This paper also compares the findings of a real time closed loop study against with traditional methods of protecting and controlling a 345 kV EHV transmission line, and provides guidelines to ensure dependable performance of distance protective relays during dynamic system conditions |
doi_str_mv | 10.1109/CPRE.2006.1638706 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_1638706</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1638706</ieee_id><sourcerecordid>1638706</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-b3b2f3223e95affa54f45417192fb62381e51993b26da2848be58ab6279731943</originalsourceid><addsrcrecordid>eNo9kN1KAzEQhQMiKLUPIN7MnXrRmr_9yaWUaoWCRdTbkt2dtJHdZElCse_iw3arxbmZjzNnDswQcs3olDGqHmart_mUU5pPWS7KguZnZKyKkkkuJaVS0AsyjvGLDiUzKSS_JD8rDAbrZN0G-gF96LSrEbyBxsb0y33w6WjZIQRs9T6Cdg3YdDtAjL62OmEDvW19-vd6B7HeYocRrAP8TkHD1m62sPNt0huEu_ni8x4G2cXOxnhcaK1D0H3f2lofE-IVOTe6jTg-9RH5eJq_zxaT5evzy-xxObGsyNKkEhU3gnOBKtPG6Eya4TxWMMVNlXNRMsyYUoMrbzQvZVlhVuphUqhCMCXFiNz85VpEXPfBdjrs16cfigMNa2pE</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Perfecting performance of distance protective relays and it's associated pilot protection schemes in extra high voltage (EHV) transmission line applications</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Lucia, M. ; Cezari, R. ; Erwin, D. ; Theron, J.C. ; Thakur, M.</creator><creatorcontrib>Lucia, M. ; Cezari, R. ; Erwin, D. ; Theron, J.C. ; Thakur, M.</creatorcontrib><description>The fundamentals of protective relaying of EHV transmission lines such as 345 kV is to ensure secure protection for all line s internal faults, and stable operation for all foresee-able external faults during system contingencies. This paper provides an overview of how utilities have traditionally applied distance protection relays and its associated pilot protection schemes for protecting EHV transmission lines. These traditional methods cover most aspects of the protection and control of EHV lines, however these methods lack in performance when they are subjected to actual power system and fault conditions. This paper highlights the needs in perfecting distance protection relays and its associated pilot protection schemes for EHV transmission lines ensuring reliable performance during all foresee-able system load and fault conditions. This paper also compares the findings of a real time closed loop study against with traditional methods of protecting and controlling a 345 kV EHV transmission line, and provides guidelines to ensure dependable performance of distance protective relays during dynamic system conditions</description><identifier>ISBN: 9781424400430</identifier><identifier>ISBN: 1424400430</identifier><identifier>DOI: 10.1109/CPRE.2006.1638706</identifier><language>eng</language><publisher>IEEE</publisher><subject>Control systems ; Power system control ; Power system faults ; Power system protection ; Power system relaying ; Power system reliability ; Power transmission lines ; Protective relaying ; Transmission lines ; Voltage</subject><ispartof>59th Annual Conference for Protective Relay Engineers, 2006, 2006, p.19 pp.</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1638706$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1638706$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Lucia, M.</creatorcontrib><creatorcontrib>Cezari, R.</creatorcontrib><creatorcontrib>Erwin, D.</creatorcontrib><creatorcontrib>Theron, J.C.</creatorcontrib><creatorcontrib>Thakur, M.</creatorcontrib><title>Perfecting performance of distance protective relays and it's associated pilot protection schemes in extra high voltage (EHV) transmission line applications</title><title>59th Annual Conference for Protective Relay Engineers, 2006</title><addtitle>CPRE</addtitle><description>The fundamentals of protective relaying of EHV transmission lines such as 345 kV is to ensure secure protection for all line s internal faults, and stable operation for all foresee-able external faults during system contingencies. This paper provides an overview of how utilities have traditionally applied distance protection relays and its associated pilot protection schemes for protecting EHV transmission lines. These traditional methods cover most aspects of the protection and control of EHV lines, however these methods lack in performance when they are subjected to actual power system and fault conditions. This paper highlights the needs in perfecting distance protection relays and its associated pilot protection schemes for EHV transmission lines ensuring reliable performance during all foresee-able system load and fault conditions. This paper also compares the findings of a real time closed loop study against with traditional methods of protecting and controlling a 345 kV EHV transmission line, and provides guidelines to ensure dependable performance of distance protective relays during dynamic system conditions</description><subject>Control systems</subject><subject>Power system control</subject><subject>Power system faults</subject><subject>Power system protection</subject><subject>Power system relaying</subject><subject>Power system reliability</subject><subject>Power transmission lines</subject><subject>Protective relaying</subject><subject>Transmission lines</subject><subject>Voltage</subject><isbn>9781424400430</isbn><isbn>1424400430</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2006</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo9kN1KAzEQhQMiKLUPIN7MnXrRmr_9yaWUaoWCRdTbkt2dtJHdZElCse_iw3arxbmZjzNnDswQcs3olDGqHmart_mUU5pPWS7KguZnZKyKkkkuJaVS0AsyjvGLDiUzKSS_JD8rDAbrZN0G-gF96LSrEbyBxsb0y33w6WjZIQRs9T6Cdg3YdDtAjL62OmEDvW19-vd6B7HeYocRrAP8TkHD1m62sPNt0huEu_ni8x4G2cXOxnhcaK1D0H3f2lofE-IVOTe6jTg-9RH5eJq_zxaT5evzy-xxObGsyNKkEhU3gnOBKtPG6Eya4TxWMMVNlXNRMsyYUoMrbzQvZVlhVuphUqhCMCXFiNz85VpEXPfBdjrs16cfigMNa2pE</recordid><startdate>2006</startdate><enddate>2006</enddate><creator>Lucia, M.</creator><creator>Cezari, R.</creator><creator>Erwin, D.</creator><creator>Theron, J.C.</creator><creator>Thakur, M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>2006</creationdate><title>Perfecting performance of distance protective relays and it's associated pilot protection schemes in extra high voltage (EHV) transmission line applications</title><author>Lucia, M. ; Cezari, R. ; Erwin, D. ; Theron, J.C. ; Thakur, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-b3b2f3223e95affa54f45417192fb62381e51993b26da2848be58ab6279731943</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Control systems</topic><topic>Power system control</topic><topic>Power system faults</topic><topic>Power system protection</topic><topic>Power system relaying</topic><topic>Power system reliability</topic><topic>Power transmission lines</topic><topic>Protective relaying</topic><topic>Transmission lines</topic><topic>Voltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Lucia, M.</creatorcontrib><creatorcontrib>Cezari, R.</creatorcontrib><creatorcontrib>Erwin, D.</creatorcontrib><creatorcontrib>Theron, J.C.</creatorcontrib><creatorcontrib>Thakur, M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library Online</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Lucia, M.</au><au>Cezari, R.</au><au>Erwin, D.</au><au>Theron, J.C.</au><au>Thakur, M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Perfecting performance of distance protective relays and it's associated pilot protection schemes in extra high voltage (EHV) transmission line applications</atitle><btitle>59th Annual Conference for Protective Relay Engineers, 2006</btitle><stitle>CPRE</stitle><date>2006</date><risdate>2006</risdate><spage>19 pp.</spage><pages>19 pp.-</pages><isbn>9781424400430</isbn><isbn>1424400430</isbn><abstract>The fundamentals of protective relaying of EHV transmission lines such as 345 kV is to ensure secure protection for all line s internal faults, and stable operation for all foresee-able external faults during system contingencies. This paper provides an overview of how utilities have traditionally applied distance protection relays and its associated pilot protection schemes for protecting EHV transmission lines. These traditional methods cover most aspects of the protection and control of EHV lines, however these methods lack in performance when they are subjected to actual power system and fault conditions. This paper highlights the needs in perfecting distance protection relays and its associated pilot protection schemes for EHV transmission lines ensuring reliable performance during all foresee-able system load and fault conditions. This paper also compares the findings of a real time closed loop study against with traditional methods of protecting and controlling a 345 kV EHV transmission line, and provides guidelines to ensure dependable performance of distance protective relays during dynamic system conditions</abstract><pub>IEEE</pub><doi>10.1109/CPRE.2006.1638706</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781424400430 |
ispartof | 59th Annual Conference for Protective Relay Engineers, 2006, 2006, p.19 pp. |
issn | |
language | eng |
recordid | cdi_ieee_primary_1638706 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Control systems Power system control Power system faults Power system protection Power system relaying Power system reliability Power transmission lines Protective relaying Transmission lines Voltage |
title | Perfecting performance of distance protective relays and it's associated pilot protection schemes in extra high voltage (EHV) transmission line applications |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T07%3A41%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Perfecting%20performance%20of%20distance%20protective%20relays%20and%20it's%20associated%20pilot%20protection%20schemes%20in%20extra%20high%20voltage%20(EHV)%20transmission%20line%20applications&rft.btitle=59th%20Annual%20Conference%20for%20Protective%20Relay%20Engineers,%202006&rft.au=Lucia,%20M.&rft.date=2006&rft.spage=19%20pp.&rft.pages=19%20pp.-&rft.isbn=9781424400430&rft.isbn_list=1424400430&rft_id=info:doi/10.1109/CPRE.2006.1638706&rft_dat=%3Cieee_6IE%3E1638706%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-b3b2f3223e95affa54f45417192fb62381e51993b26da2848be58ab6279731943%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=1638706&rfr_iscdi=true |