A general rule for determining the best operating point and load impedance for any power amplifier when anode voltage and dissipation limits must both be considered is derived. The effect of varying the voltage factor in a given sized tube by changing the grid structure is also considered with volta...

Full description

Saved in:
Bibliographic Details
Published in:Proceedings of the IRE 1928-04, Vol.16 (4), p.462-474
Main Authors: Hanna, C.R., Sutherlin, L., Upp, C.B.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A general rule for determining the best operating point and load impedance for any power amplifier when anode voltage and dissipation limits must both be considered is derived. The effect of varying the voltage factor in a given sized tube by changing the grid structure is also considered with voltage and heating kept within safe limits. The process of determining the desired characteristics for a given application is illustrated by describinq the development of a new power tube, Radiotron UX-250.