Loading…
Current and voltage harmonic measurements and modeling at the Gardner photovoltaic project
Measurements on harmonics taken at the Gardner photovoltaic (PV) project during the summer of 1987 are reported. The project includes 28 PV homes, each with a roof-mounted 2 kW PV system, connected to one phase of a 13.8 kV three-phase feeder. The measurements discussed pertain to voltage and curren...
Saved in:
Published in: | IEEE transactions on power delivery 1989-01, Vol.4 (1), p.800-809 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3 |
---|---|
cites | cdi_FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3 |
container_end_page | 809 |
container_issue | 1 |
container_start_page | 800 |
container_title | IEEE transactions on power delivery |
container_volume | 4 |
creator | Cyganski, D. Orr, J.A. Chakravorti, A.K. Emanuel, A.E. Gulachenski, E.M. Root, C.E. Bellemare, R.C. |
description | Measurements on harmonics taken at the Gardner photovoltaic (PV) project during the summer of 1987 are reported. The project includes 28 PV homes, each with a roof-mounted 2 kW PV system, connected to one phase of a 13.8 kV three-phase feeder. The measurements discussed pertain to voltage and current distortion and power flow. Theoretical calculations were carried out in order to study the effects of PV inverters other than the type installed for this study. Computer modeling of the feeder in Gardner indicates, and measurements confirm, that small increases (0.2%) in voltage total harmonic distortion will occur on this feeder with the indicated penetration of PV systems using high-quality, forced-commutation inverters.< > |
doi_str_mv | 10.1109/61.19273 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_19273</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>19273</ieee_id><sourcerecordid>28234111</sourcerecordid><originalsourceid>FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3</originalsourceid><addsrcrecordid>eNpN0DFPwzAQBWALgUQpSKxsWUAsKT47je0RVVCQKrHAwhJdnEubKomL7SDx7wktEkw33PfeScfYJfAZADd3OczACCWP2ASMVGkmuD5mE671PNVGqVN2FsKWc55xwyfsfTF4T31MsK-ST9dGXFOyQd-5vrFJRxgGT90Iwl50rqK26dcJxiRuKFmir3ryyW7jotvHx9TOuy3ZeM5OamwDXfzOKXt7fHhdPKWrl-Xz4n6VWikhpkobqMBaNFzZquQl6kyqDBHKUuRERhKWcz2vrdWcqKRMlLUSgCLTtYRaTtnNoXe8-zFQiEXXBEttiz25IRRCC5kBwAhvD9B6F4Knutj5pkP_VQAvfp5X5FDsnzfS699ODBbb2mNvm_DnjTDG5Gp0VwfXENH_9djxDR7ReFU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28234111</pqid></control><display><type>article</type><title>Current and voltage harmonic measurements and modeling at the Gardner photovoltaic project</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Cyganski, D. ; Orr, J.A. ; Chakravorti, A.K. ; Emanuel, A.E. ; Gulachenski, E.M. ; Root, C.E. ; Bellemare, R.C.</creator><creatorcontrib>Cyganski, D. ; Orr, J.A. ; Chakravorti, A.K. ; Emanuel, A.E. ; Gulachenski, E.M. ; Root, C.E. ; Bellemare, R.C.</creatorcontrib><description>Measurements on harmonics taken at the Gardner photovoltaic (PV) project during the summer of 1987 are reported. The project includes 28 PV homes, each with a roof-mounted 2 kW PV system, connected to one phase of a 13.8 kV three-phase feeder. The measurements discussed pertain to voltage and current distortion and power flow. Theoretical calculations were carried out in order to study the effects of PV inverters other than the type installed for this study. Computer modeling of the feeder in Gardner indicates, and measurements confirm, that small increases (0.2%) in voltage total harmonic distortion will occur on this feeder with the indicated penetration of PV systems using high-quality, forced-commutation inverters.< ></description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/61.19273</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Applied sciences ; Current measurement ; Direct energy conversion and energy accumulation ; Distortion measurement ; Electrical engineering. Electrical power engineering ; Electrical power engineering ; Exact sciences and technology ; Fluid flow measurement ; Inverters ; Load flow ; Photoelectric conversion ; Photovoltaic systems ; Power measurement ; Power system modeling ; Solar power generation ; Voltage measurement</subject><ispartof>IEEE transactions on power delivery, 1989-01, Vol.4 (1), p.800-809</ispartof><rights>1991 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3</citedby><cites>FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/19273$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,4036,4037,23909,23910,25118,27901,27902,54771</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=19299967$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Cyganski, D.</creatorcontrib><creatorcontrib>Orr, J.A.</creatorcontrib><creatorcontrib>Chakravorti, A.K.</creatorcontrib><creatorcontrib>Emanuel, A.E.</creatorcontrib><creatorcontrib>Gulachenski, E.M.</creatorcontrib><creatorcontrib>Root, C.E.</creatorcontrib><creatorcontrib>Bellemare, R.C.</creatorcontrib><title>Current and voltage harmonic measurements and modeling at the Gardner photovoltaic project</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>Measurements on harmonics taken at the Gardner photovoltaic (PV) project during the summer of 1987 are reported. The project includes 28 PV homes, each with a roof-mounted 2 kW PV system, connected to one phase of a 13.8 kV three-phase feeder. The measurements discussed pertain to voltage and current distortion and power flow. Theoretical calculations were carried out in order to study the effects of PV inverters other than the type installed for this study. Computer modeling of the feeder in Gardner indicates, and measurements confirm, that small increases (0.2%) in voltage total harmonic distortion will occur on this feeder with the indicated penetration of PV systems using high-quality, forced-commutation inverters.< ></description><subject>Applied sciences</subject><subject>Current measurement</subject><subject>Direct energy conversion and energy accumulation</subject><subject>Distortion measurement</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Fluid flow measurement</subject><subject>Inverters</subject><subject>Load flow</subject><subject>Photoelectric conversion</subject><subject>Photovoltaic systems</subject><subject>Power measurement</subject><subject>Power system modeling</subject><subject>Solar power generation</subject><subject>Voltage measurement</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><recordid>eNpN0DFPwzAQBWALgUQpSKxsWUAsKT47je0RVVCQKrHAwhJdnEubKomL7SDx7wktEkw33PfeScfYJfAZADd3OczACCWP2ASMVGkmuD5mE671PNVGqVN2FsKWc55xwyfsfTF4T31MsK-ST9dGXFOyQd-5vrFJRxgGT90Iwl50rqK26dcJxiRuKFmir3ryyW7jotvHx9TOuy3ZeM5OamwDXfzOKXt7fHhdPKWrl-Xz4n6VWikhpkobqMBaNFzZquQl6kyqDBHKUuRERhKWcz2vrdWcqKRMlLUSgCLTtYRaTtnNoXe8-zFQiEXXBEttiz25IRRCC5kBwAhvD9B6F4Knutj5pkP_VQAvfp5X5FDsnzfS699ODBbb2mNvm_DnjTDG5Gp0VwfXENH_9djxDR7ReFU</recordid><startdate>198901</startdate><enddate>198901</enddate><creator>Cyganski, D.</creator><creator>Orr, J.A.</creator><creator>Chakravorti, A.K.</creator><creator>Emanuel, A.E.</creator><creator>Gulachenski, E.M.</creator><creator>Root, C.E.</creator><creator>Bellemare, R.C.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>198901</creationdate><title>Current and voltage harmonic measurements and modeling at the Gardner photovoltaic project</title><author>Cyganski, D. ; Orr, J.A. ; Chakravorti, A.K. ; Emanuel, A.E. ; Gulachenski, E.M. ; Root, C.E. ; Bellemare, R.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Applied sciences</topic><topic>Current measurement</topic><topic>Direct energy conversion and energy accumulation</topic><topic>Distortion measurement</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Fluid flow measurement</topic><topic>Inverters</topic><topic>Load flow</topic><topic>Photoelectric conversion</topic><topic>Photovoltaic systems</topic><topic>Power measurement</topic><topic>Power system modeling</topic><topic>Solar power generation</topic><topic>Voltage measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cyganski, D.</creatorcontrib><creatorcontrib>Orr, J.A.</creatorcontrib><creatorcontrib>Chakravorti, A.K.</creatorcontrib><creatorcontrib>Emanuel, A.E.</creatorcontrib><creatorcontrib>Gulachenski, E.M.</creatorcontrib><creatorcontrib>Root, C.E.</creatorcontrib><creatorcontrib>Bellemare, R.C.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cyganski, D.</au><au>Orr, J.A.</au><au>Chakravorti, A.K.</au><au>Emanuel, A.E.</au><au>Gulachenski, E.M.</au><au>Root, C.E.</au><au>Bellemare, R.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Current and voltage harmonic measurements and modeling at the Gardner photovoltaic project</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>1989-01</date><risdate>1989</risdate><volume>4</volume><issue>1</issue><spage>800</spage><epage>809</epage><pages>800-809</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>Measurements on harmonics taken at the Gardner photovoltaic (PV) project during the summer of 1987 are reported. The project includes 28 PV homes, each with a roof-mounted 2 kW PV system, connected to one phase of a 13.8 kV three-phase feeder. The measurements discussed pertain to voltage and current distortion and power flow. Theoretical calculations were carried out in order to study the effects of PV inverters other than the type installed for this study. Computer modeling of the feeder in Gardner indicates, and measurements confirm, that small increases (0.2%) in voltage total harmonic distortion will occur on this feeder with the indicated penetration of PV systems using high-quality, forced-commutation inverters.< ></abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/61.19273</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0885-8977 |
ispartof | IEEE transactions on power delivery, 1989-01, Vol.4 (1), p.800-809 |
issn | 0885-8977 1937-4208 |
language | eng |
recordid | cdi_ieee_primary_19273 |
source | IEEE Electronic Library (IEL) Journals |
subjects | Applied sciences Current measurement Direct energy conversion and energy accumulation Distortion measurement Electrical engineering. Electrical power engineering Electrical power engineering Exact sciences and technology Fluid flow measurement Inverters Load flow Photoelectric conversion Photovoltaic systems Power measurement Power system modeling Solar power generation Voltage measurement |
title | Current and voltage harmonic measurements and modeling at the Gardner photovoltaic project |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T17%3A41%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Current%20and%20voltage%20harmonic%20measurements%20and%20modeling%20at%20the%20Gardner%20photovoltaic%20project&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Cyganski,%20D.&rft.date=1989-01&rft.volume=4&rft.issue=1&rft.spage=800&rft.epage=809&rft.pages=800-809&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/61.19273&rft_dat=%3Cproquest_ieee_%3E28234111%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c331t-7891d1cca907cdb0ba84374aa1bb26ee93eab585fcc80eebe42bf721a248f31f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28234111&rft_id=info:pmid/&rft_ieee_id=19273&rfr_iscdi=true |