Loading…
Dipole design for the Euterpe storage ring
The magnet system of the Eindhoven synchrotron radiation source EUTERPE (400 MeV) consists of dipoles of unconventional design and construction. Laminated rectangular blocks of transformer steel are fixed together and comprise the dipole magnet (dim. 48/spl times/39/spl times/35 cm/sup 3/). Apart fr...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The magnet system of the Eindhoven synchrotron radiation source EUTERPE (400 MeV) consists of dipoles of unconventional design and construction. Laminated rectangular blocks of transformer steel are fixed together and comprise the dipole magnet (dim. 48/spl times/39/spl times/35 cm/sup 3/). Apart from a small quadrupole component, a field uniformity /spl Delta/B/B of 2/spl times/10/sup -4/ over 4 cm at 1 T is obtained in a 2.5. cm gap. The support system is based on static and dynamic analysis. The resultant "six degree of freedom" manipulator (position accuracy /spl ap/0.02 mm) can easily adjust 3 positions and 3 angles of rotation of the magnet. Because of the stroke of the adjustable rods being small (/spl ap/5 mm), these rods have "elastic hinges" as attachment points. Design and construction have been done at the Central Design and Engineering Facilities of the Eindhoven University. A description of the magnet system, prototype magnetic field measurements and details on the construction, including that of the support system, are presented.< > |
---|---|
DOI: | 10.1109/PAC.1993.309496 |