Loading…

A Calibration Algorithm for Mutual Coupling Errors of Array Sensors Based on the Nonlinear Constraint

A new calibration approach needing one calibration source is presented to estimate the mutual coupling coefficients of uniform circular array. Firstly, the data collection is done by placing one assistant source in different direction. Then the cost function is present by using the signal subspace v...

Full description

Saved in:
Bibliographic Details
Main Authors: Cheng Chun-yue, Lv Ying-hua
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new calibration approach needing one calibration source is presented to estimate the mutual coupling coefficients of uniform circular array. Firstly, the data collection is done by placing one assistant source in different direction. Then the cost function is present by using the signal subspace vector and noise subspace vector of data covariance matrix. Under the nonlinear constraint, the union DOA estimation of assistant source and the mutual coupling coefficients of uniform circular array are given by iterative operation. The algorithm does not need know the direction of assistant source. Simulations show validity of the algorithm
DOI:10.1109/CEEM.2006.258001