Loading…

Design Parameters and Test Results for a Fission Counter Intended for Operation up to 750°F at High Gamma Dose Rates

A fission counter was built and successfully tested for operation at 750°F and gamma dose rates up to 6 × 106 R/hr. Results from gamma and neutron tests were compared with theoretical predictions and used to optimize the performance of the counters.

Saved in:
Bibliographic Details
Published in:IEEE transactions on nuclear science 1975-02, Vol.22 (1), p.696-701
Main Authors: Pare, V. K., Clay, W. T., De Lorenzo, J. T., Guerrant, G. C.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A fission counter was built and successfully tested for operation at 750°F and gamma dose rates up to 6 × 106 R/hr. Results from gamma and neutron tests were compared with theoretical predictions and used to optimize the performance of the counters.
ISSN:0018-9499
1558-1578