Loading…

Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System

Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different mole...

Full description

Saved in:
Bibliographic Details
Published in:IEEE sensors journal 2007-12, Vol.7 (12), p.1680-1684
Main Authors: Schlecht, U., Gronewold, T.M.A., Malave, A., Tewes, M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213
cites cdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213
container_end_page 1684
container_issue 12
container_start_page 1680
container_title IEEE sensors journal
container_volume 7
creator Schlecht, U.
Gronewold, T.M.A.
Malave, A.
Tewes, M.
description Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.
doi_str_mv 10.1109/JSEN.2007.909230
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_4373307</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4373307</ieee_id><sourcerecordid>880675808</sourcerecordid><originalsourceid>FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</originalsourceid><addsrcrecordid>eNqFkbFOwzAQQC0EEqWwI7FYDDClnGM7tkcoBYoqQFAJNstJLhDUxsVOB_h6UooYGGC6k-7d6e4eIfsMBoyBObl-GN0MUgA1MGBSDhukx6TUCVNCb65yDong6mmb7MT4CsCMkqpH7s6xxaKtfUN9Re-xwEXrQzKpn11T0nHTYnBf5Ugf6_aFuoZeXn3Q8XyBpWsKpGe1j9hEH-jDe2xxvku2KjeLuPcd-2R6MZoOr5LJ7eV4eDpJCq5lm7jMoRDcScZ4IRWTeSU0ZszlZZmVxmkUWY4qF11NcQ3GQGmKXJkqrUTKeJ8cr8cugn9bYmztvI4FzmauQb-M1gDPum8Y8y-pNWRKatAdefQnyYVgTHZb98nhL_DVL0PTnWt1JqRhKZcdBGuoCD7GgJVdhHruwrtlYFfK7EqZXSmza2Vdy8G6pUbEH7yzxjko_gm2FJCg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>864591235</pqid></control><display><type>article</type><title>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Schlecht, U. ; Gronewold, T.M.A. ; Malave, A. ; Tewes, M.</creator><creatorcontrib>Schlecht, U. ; Gronewold, T.M.A. ; Malave, A. ; Tewes, M.</creatorcontrib><description>Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2007.909230</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Acoustic signal detection ; Antibodies ; Biological interactions ; Biosensor ; Biosensors ; Capacitors ; Electrodes ; Frequency ; Impedance ; interdigitated capacitors ; Nanobioscience ; Nanocomposites ; nanogap ; Nanomaterials ; Nanostructure ; Prostate cancer ; prostate specific antigen (PSA) ; Sensors ; Signal to noise ratio ; Surface impedance</subject><ispartof>IEEE sensors journal, 2007-12, Vol.7 (12), p.1680-1684</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2007</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</citedby><cites>FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4373307$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Schlecht, U.</creatorcontrib><creatorcontrib>Gronewold, T.M.A.</creatorcontrib><creatorcontrib>Malave, A.</creatorcontrib><creatorcontrib>Tewes, M.</creatorcontrib><title>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.</description><subject>Acoustic signal detection</subject><subject>Antibodies</subject><subject>Biological interactions</subject><subject>Biosensor</subject><subject>Biosensors</subject><subject>Capacitors</subject><subject>Electrodes</subject><subject>Frequency</subject><subject>Impedance</subject><subject>interdigitated capacitors</subject><subject>Nanobioscience</subject><subject>Nanocomposites</subject><subject>nanogap</subject><subject>Nanomaterials</subject><subject>Nanostructure</subject><subject>Prostate cancer</subject><subject>prostate specific antigen (PSA)</subject><subject>Sensors</subject><subject>Signal to noise ratio</subject><subject>Surface impedance</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkbFOwzAQQC0EEqWwI7FYDDClnGM7tkcoBYoqQFAJNstJLhDUxsVOB_h6UooYGGC6k-7d6e4eIfsMBoyBObl-GN0MUgA1MGBSDhukx6TUCVNCb65yDong6mmb7MT4CsCMkqpH7s6xxaKtfUN9Re-xwEXrQzKpn11T0nHTYnBf5Ugf6_aFuoZeXn3Q8XyBpWsKpGe1j9hEH-jDe2xxvku2KjeLuPcd-2R6MZoOr5LJ7eV4eDpJCq5lm7jMoRDcScZ4IRWTeSU0ZszlZZmVxmkUWY4qF11NcQ3GQGmKXJkqrUTKeJ8cr8cugn9bYmztvI4FzmauQb-M1gDPum8Y8y-pNWRKatAdefQnyYVgTHZb98nhL_DVL0PTnWt1JqRhKZcdBGuoCD7GgJVdhHruwrtlYFfK7EqZXSmza2Vdy8G6pUbEH7yzxjko_gm2FJCg</recordid><startdate>200712</startdate><enddate>200712</enddate><creator>Schlecht, U.</creator><creator>Gronewold, T.M.A.</creator><creator>Malave, A.</creator><creator>Tewes, M.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>200712</creationdate><title>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</title><author>Schlecht, U. ; Gronewold, T.M.A. ; Malave, A. ; Tewes, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Acoustic signal detection</topic><topic>Antibodies</topic><topic>Biological interactions</topic><topic>Biosensor</topic><topic>Biosensors</topic><topic>Capacitors</topic><topic>Electrodes</topic><topic>Frequency</topic><topic>Impedance</topic><topic>interdigitated capacitors</topic><topic>Nanobioscience</topic><topic>Nanocomposites</topic><topic>nanogap</topic><topic>Nanomaterials</topic><topic>Nanostructure</topic><topic>Prostate cancer</topic><topic>prostate specific antigen (PSA)</topic><topic>Sensors</topic><topic>Signal to noise ratio</topic><topic>Surface impedance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schlecht, U.</creatorcontrib><creatorcontrib>Gronewold, T.M.A.</creatorcontrib><creatorcontrib>Malave, A.</creatorcontrib><creatorcontrib>Tewes, M.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore (Online service)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schlecht, U.</au><au>Gronewold, T.M.A.</au><au>Malave, A.</au><au>Tewes, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2007-12</date><risdate>2007</risdate><volume>7</volume><issue>12</issue><spage>1680</spage><epage>1684</epage><pages>1680-1684</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/JSEN.2007.909230</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1530-437X
ispartof IEEE sensors journal, 2007-12, Vol.7 (12), p.1680-1684
issn 1530-437X
1558-1748
language eng
recordid cdi_ieee_primary_4373307
source IEEE Electronic Library (IEL) Journals
subjects Acoustic signal detection
Antibodies
Biological interactions
Biosensor
Biosensors
Capacitors
Electrodes
Frequency
Impedance
interdigitated capacitors
Nanobioscience
Nanocomposites
nanogap
Nanomaterials
Nanostructure
Prostate cancer
prostate specific antigen (PSA)
Sensors
Signal to noise ratio
Surface impedance
title Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T10%3A31%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Detection%20of%20Receptor-Ligand%20Interactions%20With%20an%20GHz%20Impedance%20Biosensor%20System&rft.jtitle=IEEE%20sensors%20journal&rft.au=Schlecht,%20U.&rft.date=2007-12&rft.volume=7&rft.issue=12&rft.spage=1680&rft.epage=1684&rft.pages=1680-1684&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2007.909230&rft_dat=%3Cproquest_ieee_%3E880675808%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=864591235&rft_id=info:pmid/&rft_ieee_id=4373307&rfr_iscdi=true