Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System
Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different mole...
Saved in:
Published in: | IEEE sensors journal 2007-12, Vol.7 (12), p.1680-1684 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213 |
---|---|
cites | cdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213 |
container_end_page | 1684 |
container_issue | 12 |
container_start_page | 1680 |
container_title | IEEE sensors journal |
container_volume | 7 |
creator | Schlecht, U. Gronewold, T.M.A. Malave, A. Tewes, M. |
description | Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM. |
doi_str_mv | 10.1109/JSEN.2007.909230 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_4373307</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4373307</ieee_id><sourcerecordid>880675808</sourcerecordid><originalsourceid>FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</originalsourceid><addsrcrecordid>eNqFkbFOwzAQQC0EEqWwI7FYDDClnGM7tkcoBYoqQFAJNstJLhDUxsVOB_h6UooYGGC6k-7d6e4eIfsMBoyBObl-GN0MUgA1MGBSDhukx6TUCVNCb65yDong6mmb7MT4CsCMkqpH7s6xxaKtfUN9Re-xwEXrQzKpn11T0nHTYnBf5Ugf6_aFuoZeXn3Q8XyBpWsKpGe1j9hEH-jDe2xxvku2KjeLuPcd-2R6MZoOr5LJ7eV4eDpJCq5lm7jMoRDcScZ4IRWTeSU0ZszlZZmVxmkUWY4qF11NcQ3GQGmKXJkqrUTKeJ8cr8cugn9bYmztvI4FzmauQb-M1gDPum8Y8y-pNWRKatAdefQnyYVgTHZb98nhL_DVL0PTnWt1JqRhKZcdBGuoCD7GgJVdhHruwrtlYFfK7EqZXSmza2Vdy8G6pUbEH7yzxjko_gm2FJCg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>864591235</pqid></control><display><type>article</type><title>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Schlecht, U. ; Gronewold, T.M.A. ; Malave, A. ; Tewes, M.</creator><creatorcontrib>Schlecht, U. ; Gronewold, T.M.A. ; Malave, A. ; Tewes, M.</creatorcontrib><description>Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2007.909230</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Acoustic signal detection ; Antibodies ; Biological interactions ; Biosensor ; Biosensors ; Capacitors ; Electrodes ; Frequency ; Impedance ; interdigitated capacitors ; Nanobioscience ; Nanocomposites ; nanogap ; Nanomaterials ; Nanostructure ; Prostate cancer ; prostate specific antigen (PSA) ; Sensors ; Signal to noise ratio ; Surface impedance</subject><ispartof>IEEE sensors journal, 2007-12, Vol.7 (12), p.1680-1684</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2007</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</citedby><cites>FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4373307$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Schlecht, U.</creatorcontrib><creatorcontrib>Gronewold, T.M.A.</creatorcontrib><creatorcontrib>Malave, A.</creatorcontrib><creatorcontrib>Tewes, M.</creatorcontrib><title>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.</description><subject>Acoustic signal detection</subject><subject>Antibodies</subject><subject>Biological interactions</subject><subject>Biosensor</subject><subject>Biosensors</subject><subject>Capacitors</subject><subject>Electrodes</subject><subject>Frequency</subject><subject>Impedance</subject><subject>interdigitated capacitors</subject><subject>Nanobioscience</subject><subject>Nanocomposites</subject><subject>nanogap</subject><subject>Nanomaterials</subject><subject>Nanostructure</subject><subject>Prostate cancer</subject><subject>prostate specific antigen (PSA)</subject><subject>Sensors</subject><subject>Signal to noise ratio</subject><subject>Surface impedance</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkbFOwzAQQC0EEqWwI7FYDDClnGM7tkcoBYoqQFAJNstJLhDUxsVOB_h6UooYGGC6k-7d6e4eIfsMBoyBObl-GN0MUgA1MGBSDhukx6TUCVNCb65yDong6mmb7MT4CsCMkqpH7s6xxaKtfUN9Re-xwEXrQzKpn11T0nHTYnBf5Ugf6_aFuoZeXn3Q8XyBpWsKpGe1j9hEH-jDe2xxvku2KjeLuPcd-2R6MZoOr5LJ7eV4eDpJCq5lm7jMoRDcScZ4IRWTeSU0ZszlZZmVxmkUWY4qF11NcQ3GQGmKXJkqrUTKeJ8cr8cugn9bYmztvI4FzmauQb-M1gDPum8Y8y-pNWRKatAdefQnyYVgTHZb98nhL_DVL0PTnWt1JqRhKZcdBGuoCD7GgJVdhHruwrtlYFfK7EqZXSmza2Vdy8G6pUbEH7yzxjko_gm2FJCg</recordid><startdate>200712</startdate><enddate>200712</enddate><creator>Schlecht, U.</creator><creator>Gronewold, T.M.A.</creator><creator>Malave, A.</creator><creator>Tewes, M.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>200712</creationdate><title>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</title><author>Schlecht, U. ; Gronewold, T.M.A. ; Malave, A. ; Tewes, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Acoustic signal detection</topic><topic>Antibodies</topic><topic>Biological interactions</topic><topic>Biosensor</topic><topic>Biosensors</topic><topic>Capacitors</topic><topic>Electrodes</topic><topic>Frequency</topic><topic>Impedance</topic><topic>interdigitated capacitors</topic><topic>Nanobioscience</topic><topic>Nanocomposites</topic><topic>nanogap</topic><topic>Nanomaterials</topic><topic>Nanostructure</topic><topic>Prostate cancer</topic><topic>prostate specific antigen (PSA)</topic><topic>Sensors</topic><topic>Signal to noise ratio</topic><topic>Surface impedance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schlecht, U.</creatorcontrib><creatorcontrib>Gronewold, T.M.A.</creatorcontrib><creatorcontrib>Malave, A.</creatorcontrib><creatorcontrib>Tewes, M.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore (Online service)</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schlecht, U.</au><au>Gronewold, T.M.A.</au><au>Malave, A.</au><au>Tewes, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2007-12</date><risdate>2007</risdate><volume>7</volume><issue>12</issue><spage>1680</spage><epage>1684</epage><pages>1680-1684</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>Nanogap impedance biosensors with an electrode separation of 75 nm have been used for the specific detection of biological interactions. Different model systems, such as thrombin-anti-thrombin antibody, and Rev-peptide-anti-Rev aptamer are presented to demonstrate the detectability of different molecular masses at varying concentrations. In order to improve the signal-to-noise ratio, the use of reference sensors has been explored. The interaction of prostate specific antigen (PSA) with an anti-PSA antibody is shown to demonstrate the detection at concentrations as low as 10 nM.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/JSEN.2007.909230</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1530-437X |
ispartof | IEEE sensors journal, 2007-12, Vol.7 (12), p.1680-1684 |
issn | 1530-437X 1558-1748 |
language | eng |
recordid | cdi_ieee_primary_4373307 |
source | IEEE Electronic Library (IEL) Journals |
subjects | Acoustic signal detection Antibodies Biological interactions Biosensor Biosensors Capacitors Electrodes Frequency Impedance interdigitated capacitors Nanobioscience Nanocomposites nanogap Nanomaterials Nanostructure Prostate cancer prostate specific antigen (PSA) Sensors Signal to noise ratio Surface impedance |
title | Detection of Receptor-Ligand Interactions With an GHz Impedance Biosensor System |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T10%3A31%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Detection%20of%20Receptor-Ligand%20Interactions%20With%20an%20GHz%20Impedance%20Biosensor%20System&rft.jtitle=IEEE%20sensors%20journal&rft.au=Schlecht,%20U.&rft.date=2007-12&rft.volume=7&rft.issue=12&rft.spage=1680&rft.epage=1684&rft.pages=1680-1684&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2007.909230&rft_dat=%3Cproquest_ieee_%3E880675808%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c385t-a6ae443a5113c5715bf48e61abdd6d9a8e46be7b45717380990d9cb79f2f4213%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=864591235&rft_id=info:pmid/&rft_ieee_id=4373307&rfr_iscdi=true |