Simplified Method for Radiometric Calibration of an Array Camera
Radiometric calibration of a CCD camera is a first step when quantitative measurements for pixels values will be performed in order to extract scene characteristics. Usually, the radiometric behaviour of the camera can be modelled with a polynomial function obtained from a multi- image calibration m...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Radiometric calibration of a CCD camera is a first step when quantitative measurements for pixels values will be performed in order to extract scene characteristics. Usually, the radiometric behaviour of the camera can be modelled with a polynomial function obtained from a multi- image calibration method, which analyses several pictures taken with different exposition times. In this work, a simplification of a multi-images calibration method is proposed. The method is based on the comparison of grey values of two images only, showing that obtained results are comparables to the polynomic multi-image method. The proposed method was tested with the same images used for multi-image calibration method. Exposition times were estimated without an iterative scheme. Also a method and results for distance estimation, using inverse radiometric response function, are showed in this paper. |
---|---|
DOI: | 10.1109/WISP.2007.4447619 |