An Electronic Pillbox for Continuous Monitoring of Medication Adherence

We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication...

Full description

Saved in:
Bibliographic Details
Published in:2006 International Conference of the IEEE Engineering in Medicine and Biology Society 2006-01, p.6400-6403
Main Authors: Hayes, T.L., Hunt, J.M., Adami, A., Kaye, J.A.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23
cites
container_end_page 6403
container_issue
container_start_page 6400
container_title 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
container_volume
creator Hayes, T.L.
Hunt, J.M.
Adami, A.
Kaye, J.A.
description We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device
doi_str_mv 10.1109/IEMBS.2006.260367
format article
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4463275</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4463275</ieee_id><sourcerecordid>4463275</sourcerecordid><originalsourceid>FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23</originalsourceid><addsrcrecordid>eNotz99KwzAYBfCAihtzDyDe5AU6ky__msta5hxsKKjg3UjSrxqpibQd6NuvoOfmXPzgwCHkmrMV58zebtf7u-cVMKZXoJnQ5owsrSm5BCkZEyDPyZwrZQpu2NuMLIfhk00RdmK4JDNurNRC2znZVImuOwxjn1MM9Cl2nc8_tM09rXMaYzrm40D3E465j-md5pbusYnBjTEnWjUf2GMKeEUuWtcNuPzvBXm9X7_UD8XucbOtq10RFFdjASWgt-AdOigbK6QISjbBlFrZ1nuppbHcg0XjPGDQ1iPIiZ1GHxSCWJCbv92IiIfvPn65_vcgpzdglDgBGWZPEw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Hayes, T.L. ; Hunt, J.M. ; Adami, A. ; Kaye, J.A.</creator><creatorcontrib>Hayes, T.L. ; Hunt, J.M. ; Adami, A. ; Kaye, J.A.</creatorcontrib><description>We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device</description><identifier>ISSN: 1557-170X</identifier><identifier>ISBN: 9781424400324</identifier><identifier>ISBN: 1424400325</identifier><identifier>DOI: 10.1109/IEMBS.2006.260367</identifier><identifier>PMID: 17946369</identifier><language>eng</language><publisher>IEEE</publisher><subject>Batteries ; Biomedical engineering ; Biomedical monitoring ; Cities and towns ; Couplings ; Dementia ; Drugs ; Instruments ; Micromechanical devices ; USA Councils</subject><ispartof>2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006-01, p.6400-6403</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4463275$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4463275$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Hayes, T.L.</creatorcontrib><creatorcontrib>Hunt, J.M.</creatorcontrib><creatorcontrib>Adami, A.</creatorcontrib><creatorcontrib>Kaye, J.A.</creatorcontrib><title>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</title><title>2006 International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device</description><subject>Batteries</subject><subject>Biomedical engineering</subject><subject>Biomedical monitoring</subject><subject>Cities and towns</subject><subject>Couplings</subject><subject>Dementia</subject><subject>Drugs</subject><subject>Instruments</subject><subject>Micromechanical devices</subject><subject>USA Councils</subject><issn>1557-170X</issn><isbn>9781424400324</isbn><isbn>1424400325</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>6IE</sourceid><recordid>eNotz99KwzAYBfCAihtzDyDe5AU6ky__msta5hxsKKjg3UjSrxqpibQd6NuvoOfmXPzgwCHkmrMV58zebtf7u-cVMKZXoJnQ5owsrSm5BCkZEyDPyZwrZQpu2NuMLIfhk00RdmK4JDNurNRC2znZVImuOwxjn1MM9Cl2nc8_tM09rXMaYzrm40D3E465j-md5pbusYnBjTEnWjUf2GMKeEUuWtcNuPzvBXm9X7_UD8XucbOtq10RFFdjASWgt-AdOigbK6QISjbBlFrZ1nuppbHcg0XjPGDQ1iPIiZ1GHxSCWJCbv92IiIfvPn65_vcgpzdglDgBGWZPEw</recordid><startdate>20060101</startdate><enddate>20060101</enddate><creator>Hayes, T.L.</creator><creator>Hunt, J.M.</creator><creator>Adami, A.</creator><creator>Kaye, J.A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20060101</creationdate><title>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</title><author>Hayes, T.L. ; Hunt, J.M. ; Adami, A. ; Kaye, J.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Batteries</topic><topic>Biomedical engineering</topic><topic>Biomedical monitoring</topic><topic>Cities and towns</topic><topic>Couplings</topic><topic>Dementia</topic><topic>Drugs</topic><topic>Instruments</topic><topic>Micromechanical devices</topic><topic>USA Councils</topic><toplevel>online_resources</toplevel><creatorcontrib>Hayes, T.L.</creatorcontrib><creatorcontrib>Hunt, J.M.</creatorcontrib><creatorcontrib>Adami, A.</creatorcontrib><creatorcontrib>Kaye, J.A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><jtitle>2006 International Conference of the IEEE Engineering in Medicine and Biology Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Hayes, T.L.</au><au>Hunt, J.M.</au><au>Adami, A.</au><au>Kaye, J.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</atitle><jtitle>2006 International Conference of the IEEE Engineering in Medicine and Biology Society</jtitle><stitle>IEMBS</stitle><date>2006-01-01</date><risdate>2006</risdate><spage>6400</spage><epage>6403</epage><pages>6400-6403</pages><issn>1557-170X</issn><isbn>9781424400324</isbn><isbn>1424400325</isbn><abstract>We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device</abstract><pub>IEEE</pub><pmid>17946369</pmid><doi>10.1109/IEMBS.2006.260367</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1557-170X
ispartof 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006-01, p.6400-6403
issn 1557-170X
language eng
recordid cdi_ieee_primary_4463275
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Batteries
Biomedical engineering
Biomedical monitoring
Cities and towns
Couplings
Dementia
Drugs
Instruments
Micromechanical devices
USA Councils
title An Electronic Pillbox for Continuous Monitoring of Medication Adherence
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T05%3A23%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Electronic%20Pillbox%20for%20Continuous%20Monitoring%20of%20Medication%20Adherence&rft.jtitle=2006%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Hayes,%20T.L.&rft.date=2006-01-01&rft.spage=6400&rft.epage=6403&rft.pages=6400-6403&rft.issn=1557-170X&rft.isbn=9781424400324&rft.isbn_list=1424400325&rft_id=info:doi/10.1109/IEMBS.2006.260367&rft_dat=%3Cieee_6IE%3E4463275%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/17946369&rft_ieee_id=4463275&rfr_iscdi=true