Loading…
An Electronic Pillbox for Continuous Monitoring of Medication Adherence
We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication...
Saved in:
Published in: | 2006 International Conference of the IEEE Engineering in Medicine and Biology Society 2006-01, p.6400-6403 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23 |
---|---|
cites | |
container_end_page | 6403 |
container_issue | |
container_start_page | 6400 |
container_title | 2006 International Conference of the IEEE Engineering in Medicine and Biology Society |
container_volume | |
creator | Hayes, T.L. Hunt, J.M. Adami, A. Kaye, J.A. |
description | We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device |
doi_str_mv | 10.1109/IEMBS.2006.260367 |
format | article |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4463275</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4463275</ieee_id><sourcerecordid>4463275</sourcerecordid><originalsourceid>FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23</originalsourceid><addsrcrecordid>eNotz99KwzAYBfCAihtzDyDe5AU6ky__msta5hxsKKjg3UjSrxqpibQd6NuvoOfmXPzgwCHkmrMV58zebtf7u-cVMKZXoJnQ5owsrSm5BCkZEyDPyZwrZQpu2NuMLIfhk00RdmK4JDNurNRC2znZVImuOwxjn1MM9Cl2nc8_tM09rXMaYzrm40D3E465j-md5pbusYnBjTEnWjUf2GMKeEUuWtcNuPzvBXm9X7_UD8XucbOtq10RFFdjASWgt-AdOigbK6QISjbBlFrZ1nuppbHcg0XjPGDQ1iPIiZ1GHxSCWJCbv92IiIfvPn65_vcgpzdglDgBGWZPEw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Hayes, T.L. ; Hunt, J.M. ; Adami, A. ; Kaye, J.A.</creator><creatorcontrib>Hayes, T.L. ; Hunt, J.M. ; Adami, A. ; Kaye, J.A.</creatorcontrib><description>We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device</description><identifier>ISSN: 1557-170X</identifier><identifier>ISBN: 9781424400324</identifier><identifier>ISBN: 1424400325</identifier><identifier>DOI: 10.1109/IEMBS.2006.260367</identifier><identifier>PMID: 17946369</identifier><language>eng</language><publisher>IEEE</publisher><subject>Batteries ; Biomedical engineering ; Biomedical monitoring ; Cities and towns ; Couplings ; Dementia ; Drugs ; Instruments ; Micromechanical devices ; USA Councils</subject><ispartof>2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006-01, p.6400-6403</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4463275$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4463275$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Hayes, T.L.</creatorcontrib><creatorcontrib>Hunt, J.M.</creatorcontrib><creatorcontrib>Adami, A.</creatorcontrib><creatorcontrib>Kaye, J.A.</creatorcontrib><title>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</title><title>2006 International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device</description><subject>Batteries</subject><subject>Biomedical engineering</subject><subject>Biomedical monitoring</subject><subject>Cities and towns</subject><subject>Couplings</subject><subject>Dementia</subject><subject>Drugs</subject><subject>Instruments</subject><subject>Micromechanical devices</subject><subject>USA Councils</subject><issn>1557-170X</issn><isbn>9781424400324</isbn><isbn>1424400325</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>6IE</sourceid><recordid>eNotz99KwzAYBfCAihtzDyDe5AU6ky__msta5hxsKKjg3UjSrxqpibQd6NuvoOfmXPzgwCHkmrMV58zebtf7u-cVMKZXoJnQ5owsrSm5BCkZEyDPyZwrZQpu2NuMLIfhk00RdmK4JDNurNRC2znZVImuOwxjn1MM9Cl2nc8_tM09rXMaYzrm40D3E465j-md5pbusYnBjTEnWjUf2GMKeEUuWtcNuPzvBXm9X7_UD8XucbOtq10RFFdjASWgt-AdOigbK6QISjbBlFrZ1nuppbHcg0XjPGDQ1iPIiZ1GHxSCWJCbv92IiIfvPn65_vcgpzdglDgBGWZPEw</recordid><startdate>20060101</startdate><enddate>20060101</enddate><creator>Hayes, T.L.</creator><creator>Hunt, J.M.</creator><creator>Adami, A.</creator><creator>Kaye, J.A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20060101</creationdate><title>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</title><author>Hayes, T.L. ; Hunt, J.M. ; Adami, A. ; Kaye, J.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Batteries</topic><topic>Biomedical engineering</topic><topic>Biomedical monitoring</topic><topic>Cities and towns</topic><topic>Couplings</topic><topic>Dementia</topic><topic>Drugs</topic><topic>Instruments</topic><topic>Micromechanical devices</topic><topic>USA Councils</topic><toplevel>online_resources</toplevel><creatorcontrib>Hayes, T.L.</creatorcontrib><creatorcontrib>Hunt, J.M.</creatorcontrib><creatorcontrib>Adami, A.</creatorcontrib><creatorcontrib>Kaye, J.A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><jtitle>2006 International Conference of the IEEE Engineering in Medicine and Biology Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Hayes, T.L.</au><au>Hunt, J.M.</au><au>Adami, A.</au><au>Kaye, J.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An Electronic Pillbox for Continuous Monitoring of Medication Adherence</atitle><jtitle>2006 International Conference of the IEEE Engineering in Medicine and Biology Society</jtitle><stitle>IEMBS</stitle><date>2006-01-01</date><risdate>2006</risdate><spage>6400</spage><epage>6403</epage><pages>6400-6403</pages><issn>1557-170X</issn><isbn>9781424400324</isbn><isbn>1424400325</isbn><abstract>We have developed an instrumented pillbox, called a MedTracker, which allows monitoring of medication adherence on a continuous basis. This device improves on existing systems by providing mobility, frequent and automatic data collection, more detailed information about non-adherence and medication errors, and the familiar interface of a 7-day drug store pillbox. We report on the design of the MedTracker, and on the results of a field trial in 39 homes to evaluate the device</abstract><pub>IEEE</pub><pmid>17946369</pmid><doi>10.1109/IEMBS.2006.260367</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1557-170X |
ispartof | 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006-01, p.6400-6403 |
issn | 1557-170X |
language | eng |
recordid | cdi_ieee_primary_4463275 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Batteries Biomedical engineering Biomedical monitoring Cities and towns Couplings Dementia Drugs Instruments Micromechanical devices USA Councils |
title | An Electronic Pillbox for Continuous Monitoring of Medication Adherence |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T05%3A23%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20Electronic%20Pillbox%20for%20Continuous%20Monitoring%20of%20Medication%20Adherence&rft.jtitle=2006%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Hayes,%20T.L.&rft.date=2006-01-01&rft.spage=6400&rft.epage=6403&rft.pages=6400-6403&rft.issn=1557-170X&rft.isbn=9781424400324&rft.isbn_list=1424400325&rft_id=info:doi/10.1109/IEMBS.2006.260367&rft_dat=%3Cieee_6IE%3E4463275%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c515t-282eb92baea28d9343c54dc78659fbb464791b29e7ab2ec69be24c78a6ebc5e23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/17946369&rft_ieee_id=4463275&rfr_iscdi=true |