Power quality impact of high capacity end-users

The random load variation, as in case of the arc furnaces, determines random voltage variations at the supply bus-bars., the can affect the power quality delivered to other customers, supplied by the same bus-bars. The value of the instantaneous flicker sensation S(t) is measured by means of an inst...

Full description

Saved in:
Bibliographic Details
Main Authors: Golovanov, N., Lazaroiu, G.C., Roscia, M., Zaninelli, D.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 5
container_issue
container_start_page 1
container_title
container_volume
creator Golovanov, N.
Lazaroiu, G.C.
Roscia, M.
Zaninelli, D.
description The random load variation, as in case of the arc furnaces, determines random voltage variations at the supply bus-bars., the can affect the power quality delivered to other customers, supplied by the same bus-bars. The value of the instantaneous flicker sensation S(t) is measured by means of an instrument, the so-called flickermeter. The setting-up of the flickermeter model is done in Simulink, the simulation tool, in the MATLAB environment. The present paper deals with the case study of an existing ac arc furnace facility. The 110 kV monitoring campaign was conducted using the ION 7600 equipment. The main power quality indices regarding harmonics and flicker levels are reported in the paper with reference to IEEE standards.
doi_str_mv 10.1109/ICHQP.2008.4668853
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4668853</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4668853</ieee_id><sourcerecordid>4668853</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-7a707042c15e89e602b10e579f5d22652d1300290fb12a20e3f8395a94d1822d3</originalsourceid><addsrcrecordid>eNo1kNtOwkAQhscDiS3yAnrTF1iYme7x0jQqJCRiwj1Z2q2sAcG2xPD2lohXk_n-_F8mA_BAOCZCN5kV0_fFmBHtWGptrcqvICXJUpIxaK8hYdJSoCa8gZEz9j8juoWElESh-_IA0t5hHBpGfQdp234ingkmMFnsf0KTfR_9NnanLO4OvuyyfZ1t4scmK32_nnn4qsSxDU17D4Pab9swuswhLF-el8VUzN9eZ8XTXESHnTDe9HbJJalgXdDIa8KgjKtVxawVV5T3Jzis18SeMeS1zZ3yTlZkmat8CI9_2hhCWB2auPPNaXV5Qv4LXllHrQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Power quality impact of high capacity end-users</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Golovanov, N. ; Lazaroiu, G.C. ; Roscia, M. ; Zaninelli, D.</creator><creatorcontrib>Golovanov, N. ; Lazaroiu, G.C. ; Roscia, M. ; Zaninelli, D.</creatorcontrib><description>The random load variation, as in case of the arc furnaces, determines random voltage variations at the supply bus-bars., the can affect the power quality delivered to other customers, supplied by the same bus-bars. The value of the instantaneous flicker sensation S(t) is measured by means of an instrument, the so-called flickermeter. The setting-up of the flickermeter model is done in Simulink, the simulation tool, in the MATLAB environment. The present paper deals with the case study of an existing ac arc furnace facility. The 110 kV monitoring campaign was conducted using the ION 7600 equipment. The main power quality indices regarding harmonics and flicker levels are reported in the paper with reference to IEEE standards.</description><identifier>ISSN: 1540-6008</identifier><identifier>ISBN: 9781424417711</identifier><identifier>ISBN: 1424417716</identifier><identifier>EISSN: 2164-0610</identifier><identifier>EISBN: 1424417708</identifier><identifier>EISBN: 9781424417704</identifier><identifier>DOI: 10.1109/ICHQP.2008.4668853</identifier><identifier>LCCN: 2007907206</identifier><language>eng</language><publisher>IEEE</publisher><subject>flickermeter ; Furnaces ; Instruments ; Load management ; Mathematical model ; Pollution measurement ; Power harmonic filters ; Power quality ; Power system harmonics ; Power system modeling ; voltage flicker ; Voltage fluctuations</subject><ispartof>2008 13th International Conference on Harmonics and Quality of Power, 2008, p.1-5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4668853$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,778,782,787,788,2054,27908,54903</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4668853$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Golovanov, N.</creatorcontrib><creatorcontrib>Lazaroiu, G.C.</creatorcontrib><creatorcontrib>Roscia, M.</creatorcontrib><creatorcontrib>Zaninelli, D.</creatorcontrib><title>Power quality impact of high capacity end-users</title><title>2008 13th International Conference on Harmonics and Quality of Power</title><addtitle>ICHQP</addtitle><description>The random load variation, as in case of the arc furnaces, determines random voltage variations at the supply bus-bars., the can affect the power quality delivered to other customers, supplied by the same bus-bars. The value of the instantaneous flicker sensation S(t) is measured by means of an instrument, the so-called flickermeter. The setting-up of the flickermeter model is done in Simulink, the simulation tool, in the MATLAB environment. The present paper deals with the case study of an existing ac arc furnace facility. The 110 kV monitoring campaign was conducted using the ION 7600 equipment. The main power quality indices regarding harmonics and flicker levels are reported in the paper with reference to IEEE standards.</description><subject>flickermeter</subject><subject>Furnaces</subject><subject>Instruments</subject><subject>Load management</subject><subject>Mathematical model</subject><subject>Pollution measurement</subject><subject>Power harmonic filters</subject><subject>Power quality</subject><subject>Power system harmonics</subject><subject>Power system modeling</subject><subject>voltage flicker</subject><subject>Voltage fluctuations</subject><issn>1540-6008</issn><issn>2164-0610</issn><isbn>9781424417711</isbn><isbn>1424417716</isbn><isbn>1424417708</isbn><isbn>9781424417704</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1kNtOwkAQhscDiS3yAnrTF1iYme7x0jQqJCRiwj1Z2q2sAcG2xPD2lohXk_n-_F8mA_BAOCZCN5kV0_fFmBHtWGptrcqvICXJUpIxaK8hYdJSoCa8gZEz9j8juoWElESh-_IA0t5hHBpGfQdp234ingkmMFnsf0KTfR_9NnanLO4OvuyyfZ1t4scmK32_nnn4qsSxDU17D4Pab9swuswhLF-el8VUzN9eZ8XTXESHnTDe9HbJJalgXdDIa8KgjKtVxawVV5T3Jzis18SeMeS1zZ3yTlZkmat8CI9_2hhCWB2auPPNaXV5Qv4LXllHrQ</recordid><startdate>200809</startdate><enddate>200809</enddate><creator>Golovanov, N.</creator><creator>Lazaroiu, G.C.</creator><creator>Roscia, M.</creator><creator>Zaninelli, D.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200809</creationdate><title>Power quality impact of high capacity end-users</title><author>Golovanov, N. ; Lazaroiu, G.C. ; Roscia, M. ; Zaninelli, D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-7a707042c15e89e602b10e579f5d22652d1300290fb12a20e3f8395a94d1822d3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>flickermeter</topic><topic>Furnaces</topic><topic>Instruments</topic><topic>Load management</topic><topic>Mathematical model</topic><topic>Pollution measurement</topic><topic>Power harmonic filters</topic><topic>Power quality</topic><topic>Power system harmonics</topic><topic>Power system modeling</topic><topic>voltage flicker</topic><topic>Voltage fluctuations</topic><toplevel>online_resources</toplevel><creatorcontrib>Golovanov, N.</creatorcontrib><creatorcontrib>Lazaroiu, G.C.</creatorcontrib><creatorcontrib>Roscia, M.</creatorcontrib><creatorcontrib>Zaninelli, D.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Golovanov, N.</au><au>Lazaroiu, G.C.</au><au>Roscia, M.</au><au>Zaninelli, D.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Power quality impact of high capacity end-users</atitle><btitle>2008 13th International Conference on Harmonics and Quality of Power</btitle><stitle>ICHQP</stitle><date>2008-09</date><risdate>2008</risdate><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>1540-6008</issn><eissn>2164-0610</eissn><isbn>9781424417711</isbn><isbn>1424417716</isbn><eisbn>1424417708</eisbn><eisbn>9781424417704</eisbn><abstract>The random load variation, as in case of the arc furnaces, determines random voltage variations at the supply bus-bars., the can affect the power quality delivered to other customers, supplied by the same bus-bars. The value of the instantaneous flicker sensation S(t) is measured by means of an instrument, the so-called flickermeter. The setting-up of the flickermeter model is done in Simulink, the simulation tool, in the MATLAB environment. The present paper deals with the case study of an existing ac arc furnace facility. The 110 kV monitoring campaign was conducted using the ION 7600 equipment. The main power quality indices regarding harmonics and flicker levels are reported in the paper with reference to IEEE standards.</abstract><pub>IEEE</pub><doi>10.1109/ICHQP.2008.4668853</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1540-6008
ispartof 2008 13th International Conference on Harmonics and Quality of Power, 2008, p.1-5
issn 1540-6008
2164-0610
language eng
recordid cdi_ieee_primary_4668853
source IEEE Electronic Library (IEL) Conference Proceedings
subjects flickermeter
Furnaces
Instruments
Load management
Mathematical model
Pollution measurement
Power harmonic filters
Power quality
Power system harmonics
Power system modeling
voltage flicker
Voltage fluctuations
title Power quality impact of high capacity end-users
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T22%3A03%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Power%20quality%20impact%20of%20high%20capacity%20end-users&rft.btitle=2008%2013th%20International%20Conference%20on%20Harmonics%20and%20Quality%20of%20Power&rft.au=Golovanov,%20N.&rft.date=2008-09&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=1540-6008&rft.eissn=2164-0610&rft.isbn=9781424417711&rft.isbn_list=1424417716&rft_id=info:doi/10.1109/ICHQP.2008.4668853&rft.eisbn=1424417708&rft.eisbn_list=9781424417704&rft_dat=%3Cieee_6IE%3E4668853%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i90t-7a707042c15e89e602b10e579f5d22652d1300290fb12a20e3f8395a94d1822d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4668853&rfr_iscdi=true