Effect of fenestrated stents on the renal arteries: Investigation of hemodynamic changes in abdominal aortic aneurysms treated with fenestrated endovascular grafts
This article uses a novel method of combining 3D image visualization and computational fluid dynamics to investigate the potential effect of fenestrated stents on the renal arteries in terms of blood flow pattern, flow rate at different cardiac cycles, based on patients with abdominal aortic aneurys...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 224 |
container_issue | |
container_start_page | 219 |
container_title | |
container_volume | |
creator | Zhonghua Sun Chaichana, T. Tangjitkusolmun, S. Sangwatthana, S. Allen, Y.B. Hartley, D.E. Lawrence-Brown, M. Sangworasil, M. |
description | This article uses a novel method of combining 3D image visualization and computational fluid dynamics to investigate the potential effect of fenestrated stents on the renal arteries in terms of blood flow pattern, flow rate at different cardiac cycles, based on patients with abdominal aortic aneurysm treated with fenestrated stent grafts. 3D imaging appearance of the fenestrated stents inserted into the renal arteries is used to guide the simulation of the stent protrusion into the abdominal aorta model for analysis of hemodynamic changes. A circular stent protrusion with a length of between 5-7 mm inside the abdominal aorta is simulated in two aorta models, and computational fluid dynamics is performed to detect the change of flow pattern and flow rate at the renal arteries. Our results demonstrate change of the renal flow rate is minimal following implantation of fenestrated stents, indicating the safety of fenestrated stent graft repair of patients with aortic aneurysms. |
doi_str_mv | 10.1109/ISCIT.2008.4700186 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4700186</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4700186</ieee_id><sourcerecordid>4700186</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-90fb18e2ab2b2911d3845991517a9d5b4bc2ad52843982b21951d3d321ab9a993</originalsourceid><addsrcrecordid>eNpVkN1OAjEQhWsMiYK8gN70BcD-sq13hqCSkHghXpPZ7Sxbw3ZNWzA8jy_qqnjh3ExO5jvnJEPINWdTzpm9Xb7Ml-upYMxMVcEYN7MzMuRKKCWknJlzMraF-dNaDcjwm7VMGM0vyDilN9aP0lKq4pJ8Luoaq0y7mtYYMOUIGR1NGUNOtAs0N0gjBthRiBmjx3RHl-HQk34L2fdEb22w7dwxQOsrWjUQtpioDxRK17X-x9vF3N8g4D4eU5tojvhT9OFz868Zg-sOkKr9DiLdRqhzuiKDGnYJx6c9Iq8Pi_X8abJ6flzO71cTzwudJ5bVJTcooBSlsJw7aZS2lmtegHW6VGUlwGlhlLSmR7jVPeOk4FBasFaOyM1vrkfEzXv0LcTj5vRk-QVMs3Iq</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Effect of fenestrated stents on the renal arteries: Investigation of hemodynamic changes in abdominal aortic aneurysms treated with fenestrated endovascular grafts</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Zhonghua Sun ; Chaichana, T. ; Tangjitkusolmun, S. ; Sangwatthana, S. ; Allen, Y.B. ; Hartley, D.E. ; Lawrence-Brown, M. ; Sangworasil, M.</creator><creatorcontrib>Zhonghua Sun ; Chaichana, T. ; Tangjitkusolmun, S. ; Sangwatthana, S. ; Allen, Y.B. ; Hartley, D.E. ; Lawrence-Brown, M. ; Sangworasil, M.</creatorcontrib><description>This article uses a novel method of combining 3D image visualization and computational fluid dynamics to investigate the potential effect of fenestrated stents on the renal arteries in terms of blood flow pattern, flow rate at different cardiac cycles, based on patients with abdominal aortic aneurysm treated with fenestrated stent grafts. 3D imaging appearance of the fenestrated stents inserted into the renal arteries is used to guide the simulation of the stent protrusion into the abdominal aorta model for analysis of hemodynamic changes. A circular stent protrusion with a length of between 5-7 mm inside the abdominal aorta is simulated in two aorta models, and computational fluid dynamics is performed to detect the change of flow pattern and flow rate at the renal arteries. Our results demonstrate change of the renal flow rate is minimal following implantation of fenestrated stents, indicating the safety of fenestrated stent graft repair of patients with aortic aneurysms.</description><identifier>ISBN: 9781424423354</identifier><identifier>ISBN: 142442335X</identifier><identifier>EISBN: 1424423368</identifier><identifier>EISBN: 9781424423361</identifier><identifier>DOI: 10.1109/ISCIT.2008.4700186</identifier><identifier>LCCN: 2008902851</identifier><language>eng</language><publisher>IEEE</publisher><subject>Abdomen ; Aneurysm ; aortic aneurysm ; Arteries ; Biomedical imaging ; Blood flow ; Computational fluid dynamics ; Computational modeling ; endovascular repair ; fenestration ; Hemodynamics ; Medical treatment ; simulation ; Visualization</subject><ispartof>2008 International Symposium on Communications and Information Technologies, 2008, p.219-224</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4700186$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4700186$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Zhonghua Sun</creatorcontrib><creatorcontrib>Chaichana, T.</creatorcontrib><creatorcontrib>Tangjitkusolmun, S.</creatorcontrib><creatorcontrib>Sangwatthana, S.</creatorcontrib><creatorcontrib>Allen, Y.B.</creatorcontrib><creatorcontrib>Hartley, D.E.</creatorcontrib><creatorcontrib>Lawrence-Brown, M.</creatorcontrib><creatorcontrib>Sangworasil, M.</creatorcontrib><title>Effect of fenestrated stents on the renal arteries: Investigation of hemodynamic changes in abdominal aortic aneurysms treated with fenestrated endovascular grafts</title><title>2008 International Symposium on Communications and Information Technologies</title><addtitle>ISCIT</addtitle><description>This article uses a novel method of combining 3D image visualization and computational fluid dynamics to investigate the potential effect of fenestrated stents on the renal arteries in terms of blood flow pattern, flow rate at different cardiac cycles, based on patients with abdominal aortic aneurysm treated with fenestrated stent grafts. 3D imaging appearance of the fenestrated stents inserted into the renal arteries is used to guide the simulation of the stent protrusion into the abdominal aorta model for analysis of hemodynamic changes. A circular stent protrusion with a length of between 5-7 mm inside the abdominal aorta is simulated in two aorta models, and computational fluid dynamics is performed to detect the change of flow pattern and flow rate at the renal arteries. Our results demonstrate change of the renal flow rate is minimal following implantation of fenestrated stents, indicating the safety of fenestrated stent graft repair of patients with aortic aneurysms.</description><subject>Abdomen</subject><subject>Aneurysm</subject><subject>aortic aneurysm</subject><subject>Arteries</subject><subject>Biomedical imaging</subject><subject>Blood flow</subject><subject>Computational fluid dynamics</subject><subject>Computational modeling</subject><subject>endovascular repair</subject><subject>fenestration</subject><subject>Hemodynamics</subject><subject>Medical treatment</subject><subject>simulation</subject><subject>Visualization</subject><isbn>9781424423354</isbn><isbn>142442335X</isbn><isbn>1424423368</isbn><isbn>9781424423361</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNpVkN1OAjEQhWsMiYK8gN70BcD-sq13hqCSkHghXpPZ7Sxbw3ZNWzA8jy_qqnjh3ExO5jvnJEPINWdTzpm9Xb7Ml-upYMxMVcEYN7MzMuRKKCWknJlzMraF-dNaDcjwm7VMGM0vyDilN9aP0lKq4pJ8Luoaq0y7mtYYMOUIGR1NGUNOtAs0N0gjBthRiBmjx3RHl-HQk34L2fdEb22w7dwxQOsrWjUQtpioDxRK17X-x9vF3N8g4D4eU5tojvhT9OFz868Zg-sOkKr9DiLdRqhzuiKDGnYJx6c9Iq8Pi_X8abJ6flzO71cTzwudJ5bVJTcooBSlsJw7aZS2lmtegHW6VGUlwGlhlLSmR7jVPeOk4FBasFaOyM1vrkfEzXv0LcTj5vRk-QVMs3Iq</recordid><startdate>200810</startdate><enddate>200810</enddate><creator>Zhonghua Sun</creator><creator>Chaichana, T.</creator><creator>Tangjitkusolmun, S.</creator><creator>Sangwatthana, S.</creator><creator>Allen, Y.B.</creator><creator>Hartley, D.E.</creator><creator>Lawrence-Brown, M.</creator><creator>Sangworasil, M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200810</creationdate><title>Effect of fenestrated stents on the renal arteries: Investigation of hemodynamic changes in abdominal aortic aneurysms treated with fenestrated endovascular grafts</title><author>Zhonghua Sun ; Chaichana, T. ; Tangjitkusolmun, S. ; Sangwatthana, S. ; Allen, Y.B. ; Hartley, D.E. ; Lawrence-Brown, M. ; Sangworasil, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-90fb18e2ab2b2911d3845991517a9d5b4bc2ad52843982b21951d3d321ab9a993</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Abdomen</topic><topic>Aneurysm</topic><topic>aortic aneurysm</topic><topic>Arteries</topic><topic>Biomedical imaging</topic><topic>Blood flow</topic><topic>Computational fluid dynamics</topic><topic>Computational modeling</topic><topic>endovascular repair</topic><topic>fenestration</topic><topic>Hemodynamics</topic><topic>Medical treatment</topic><topic>simulation</topic><topic>Visualization</topic><toplevel>online_resources</toplevel><creatorcontrib>Zhonghua Sun</creatorcontrib><creatorcontrib>Chaichana, T.</creatorcontrib><creatorcontrib>Tangjitkusolmun, S.</creatorcontrib><creatorcontrib>Sangwatthana, S.</creatorcontrib><creatorcontrib>Allen, Y.B.</creatorcontrib><creatorcontrib>Hartley, D.E.</creatorcontrib><creatorcontrib>Lawrence-Brown, M.</creatorcontrib><creatorcontrib>Sangworasil, M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Zhonghua Sun</au><au>Chaichana, T.</au><au>Tangjitkusolmun, S.</au><au>Sangwatthana, S.</au><au>Allen, Y.B.</au><au>Hartley, D.E.</au><au>Lawrence-Brown, M.</au><au>Sangworasil, M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Effect of fenestrated stents on the renal arteries: Investigation of hemodynamic changes in abdominal aortic aneurysms treated with fenestrated endovascular grafts</atitle><btitle>2008 International Symposium on Communications and Information Technologies</btitle><stitle>ISCIT</stitle><date>2008-10</date><risdate>2008</risdate><spage>219</spage><epage>224</epage><pages>219-224</pages><isbn>9781424423354</isbn><isbn>142442335X</isbn><eisbn>1424423368</eisbn><eisbn>9781424423361</eisbn><abstract>This article uses a novel method of combining 3D image visualization and computational fluid dynamics to investigate the potential effect of fenestrated stents on the renal arteries in terms of blood flow pattern, flow rate at different cardiac cycles, based on patients with abdominal aortic aneurysm treated with fenestrated stent grafts. 3D imaging appearance of the fenestrated stents inserted into the renal arteries is used to guide the simulation of the stent protrusion into the abdominal aorta model for analysis of hemodynamic changes. A circular stent protrusion with a length of between 5-7 mm inside the abdominal aorta is simulated in two aorta models, and computational fluid dynamics is performed to detect the change of flow pattern and flow rate at the renal arteries. Our results demonstrate change of the renal flow rate is minimal following implantation of fenestrated stents, indicating the safety of fenestrated stent graft repair of patients with aortic aneurysms.</abstract><pub>IEEE</pub><doi>10.1109/ISCIT.2008.4700186</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781424423354 |
ispartof | 2008 International Symposium on Communications and Information Technologies, 2008, p.219-224 |
issn | |
language | eng |
recordid | cdi_ieee_primary_4700186 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Abdomen Aneurysm aortic aneurysm Arteries Biomedical imaging Blood flow Computational fluid dynamics Computational modeling endovascular repair fenestration Hemodynamics Medical treatment simulation Visualization |
title | Effect of fenestrated stents on the renal arteries: Investigation of hemodynamic changes in abdominal aortic aneurysms treated with fenestrated endovascular grafts |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T09%3A30%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Effect%20of%20fenestrated%20stents%20on%20the%20renal%20arteries:%20Investigation%20of%20hemodynamic%20changes%20in%20abdominal%20aortic%20aneurysms%20treated%20with%20fenestrated%20endovascular%20grafts&rft.btitle=2008%20International%20Symposium%20on%20Communications%20and%20Information%20Technologies&rft.au=Zhonghua%20Sun&rft.date=2008-10&rft.spage=219&rft.epage=224&rft.pages=219-224&rft.isbn=9781424423354&rft.isbn_list=142442335X&rft_id=info:doi/10.1109/ISCIT.2008.4700186&rft.eisbn=1424423368&rft.eisbn_list=9781424423361&rft_dat=%3Cieee_6IE%3E4700186%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-90fb18e2ab2b2911d3845991517a9d5b4bc2ad52843982b21951d3d321ab9a993%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4700186&rfr_iscdi=true |