Loading…
Impact of MMF Space Harmonic on Rotor Losses in Fractional-Slot Permanent-Magnet Machines
The fractional-slot permanent-magnet (PM) machines are used in many applications due to their high torque density, low torque ripple, and high efficiency. However, the fractional-slot machines are characterized by high contents of space harmonics in the air-gap MMF distribution. Such harmonics cause...
Saved in:
Published in: | IEEE transactions on energy conversion 2009-06, Vol.24 (2), p.323-328 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53 |
---|---|
cites | cdi_FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53 |
container_end_page | 328 |
container_issue | 2 |
container_start_page | 323 |
container_title | IEEE transactions on energy conversion |
container_volume | 24 |
creator | Bianchi, N. Fornasiero, E. |
description | The fractional-slot permanent-magnet (PM) machines are used in many applications due to their high torque density, low torque ripple, and high efficiency. However, the fractional-slot machines are characterized by high contents of space harmonics in the air-gap MMF distribution. Such harmonics cause flux variation in the air gap, and the main consequence is the induced losses in the rotor. Depending on the combination of slots and poles of the machine, there are different harmonic contents and then rotor losses. By means of a simple model of the rotor losses, this paper investigates the link between the rotor losses and the combination of the slots and the poles of the fractional-slot PM machines. |
doi_str_mv | 10.1109/TEC.2008.2006557 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_4757261</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4757261</ieee_id><sourcerecordid>34622065</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53</originalsourceid><addsrcrecordid>eNp9kb1PwzAQxS0EEqWwI7FYDDCl-CP-yIiqllZqBKJlYIpcx4ZUiV3sdOC_x1UrBgaWO530e6e79wC4xmiEMSoeVpPxiCAk94UzJk7AADMmM4RYcQoGSEqWyYIX5-Aixg1COGcED8D7vNsq3UNvYVlO4TINBs5U6LxrNPQOvvreB7jwMZoIGwenIeGNd6rNlq3v4YsJnXLG9VmpPpzpYan0Z-NMvARnVrXRXB37ELxNJ6vxLFs8P83Hj4tMU0b7zOJCWqwoVsZQRCQTVORrq4laFzWlCnNayzWRWApmZY2xtopThATTpJaa0SG4P-zdBv-1M7GvuiZq07bpKr-LVdIhwQklibz7l6Q5JySZl8DbP-DG70J6OW1jkguekyJB6ADpkMwJxlbb0HQqfFcYVftIqhRJtY-kOkaSJDcHSWOM-cVzwQThmP4A1niFbg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>858676429</pqid></control><display><type>article</type><title>Impact of MMF Space Harmonic on Rotor Losses in Fractional-Slot Permanent-Magnet Machines</title><source>IEEE Xplore (Online service)</source><creator>Bianchi, N. ; Fornasiero, E.</creator><creatorcontrib>Bianchi, N. ; Fornasiero, E.</creatorcontrib><description>The fractional-slot permanent-magnet (PM) machines are used in many applications due to their high torque density, low torque ripple, and high efficiency. However, the fractional-slot machines are characterized by high contents of space harmonics in the air-gap MMF distribution. Such harmonics cause flux variation in the air gap, and the main consequence is the induced losses in the rotor. Depending on the combination of slots and poles of the machine, there are different harmonic contents and then rotor losses. By means of a simple model of the rotor losses, this paper investigates the link between the rotor losses and the combination of the slots and the poles of the fractional-slot PM machines.</description><identifier>ISSN: 0885-8969</identifier><identifier>EISSN: 1558-0059</identifier><identifier>DOI: 10.1109/TEC.2008.2006557</identifier><identifier>CODEN: ITCNE4</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Air gaps ; Analytical models ; Conducting materials ; Current density ; Density ; Direct power generation ; Flux ; Geometry ; Harmonics ; Permanent-magnet (PM) machines ; PM motors ; Poles ; Process design ; Ripples ; rotor losses ; Rotors ; Solids ; Torque ; variable-speed drives</subject><ispartof>IEEE transactions on energy conversion, 2009-06, Vol.24 (2), p.323-328</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2009</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53</citedby><cites>FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4757261$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,27903,27904,54774</link.rule.ids></links><search><creatorcontrib>Bianchi, N.</creatorcontrib><creatorcontrib>Fornasiero, E.</creatorcontrib><title>Impact of MMF Space Harmonic on Rotor Losses in Fractional-Slot Permanent-Magnet Machines</title><title>IEEE transactions on energy conversion</title><addtitle>TEC</addtitle><description>The fractional-slot permanent-magnet (PM) machines are used in many applications due to their high torque density, low torque ripple, and high efficiency. However, the fractional-slot machines are characterized by high contents of space harmonics in the air-gap MMF distribution. Such harmonics cause flux variation in the air gap, and the main consequence is the induced losses in the rotor. Depending on the combination of slots and poles of the machine, there are different harmonic contents and then rotor losses. By means of a simple model of the rotor losses, this paper investigates the link between the rotor losses and the combination of the slots and the poles of the fractional-slot PM machines.</description><subject>Air gaps</subject><subject>Analytical models</subject><subject>Conducting materials</subject><subject>Current density</subject><subject>Density</subject><subject>Direct power generation</subject><subject>Flux</subject><subject>Geometry</subject><subject>Harmonics</subject><subject>Permanent-magnet (PM) machines</subject><subject>PM motors</subject><subject>Poles</subject><subject>Process design</subject><subject>Ripples</subject><subject>rotor losses</subject><subject>Rotors</subject><subject>Solids</subject><subject>Torque</subject><subject>variable-speed drives</subject><issn>0885-8969</issn><issn>1558-0059</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9kb1PwzAQxS0EEqWwI7FYDDCl-CP-yIiqllZqBKJlYIpcx4ZUiV3sdOC_x1UrBgaWO530e6e79wC4xmiEMSoeVpPxiCAk94UzJk7AADMmM4RYcQoGSEqWyYIX5-Aixg1COGcED8D7vNsq3UNvYVlO4TINBs5U6LxrNPQOvvreB7jwMZoIGwenIeGNd6rNlq3v4YsJnXLG9VmpPpzpYan0Z-NMvARnVrXRXB37ELxNJ6vxLFs8P83Hj4tMU0b7zOJCWqwoVsZQRCQTVORrq4laFzWlCnNayzWRWApmZY2xtopThATTpJaa0SG4P-zdBv-1M7GvuiZq07bpKr-LVdIhwQklibz7l6Q5JySZl8DbP-DG70J6OW1jkguekyJB6ADpkMwJxlbb0HQqfFcYVftIqhRJtY-kOkaSJDcHSWOM-cVzwQThmP4A1niFbg</recordid><startdate>20090601</startdate><enddate>20090601</enddate><creator>Bianchi, N.</creator><creator>Fornasiero, E.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><scope>F28</scope></search><sort><creationdate>20090601</creationdate><title>Impact of MMF Space Harmonic on Rotor Losses in Fractional-Slot Permanent-Magnet Machines</title><author>Bianchi, N. ; Fornasiero, E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Air gaps</topic><topic>Analytical models</topic><topic>Conducting materials</topic><topic>Current density</topic><topic>Density</topic><topic>Direct power generation</topic><topic>Flux</topic><topic>Geometry</topic><topic>Harmonics</topic><topic>Permanent-magnet (PM) machines</topic><topic>PM motors</topic><topic>Poles</topic><topic>Process design</topic><topic>Ripples</topic><topic>rotor losses</topic><topic>Rotors</topic><topic>Solids</topic><topic>Torque</topic><topic>variable-speed drives</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bianchi, N.</creatorcontrib><creatorcontrib>Fornasiero, E.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><jtitle>IEEE transactions on energy conversion</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bianchi, N.</au><au>Fornasiero, E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of MMF Space Harmonic on Rotor Losses in Fractional-Slot Permanent-Magnet Machines</atitle><jtitle>IEEE transactions on energy conversion</jtitle><stitle>TEC</stitle><date>2009-06-01</date><risdate>2009</risdate><volume>24</volume><issue>2</issue><spage>323</spage><epage>328</epage><pages>323-328</pages><issn>0885-8969</issn><eissn>1558-0059</eissn><coden>ITCNE4</coden><abstract>The fractional-slot permanent-magnet (PM) machines are used in many applications due to their high torque density, low torque ripple, and high efficiency. However, the fractional-slot machines are characterized by high contents of space harmonics in the air-gap MMF distribution. Such harmonics cause flux variation in the air gap, and the main consequence is the induced losses in the rotor. Depending on the combination of slots and poles of the machine, there are different harmonic contents and then rotor losses. By means of a simple model of the rotor losses, this paper investigates the link between the rotor losses and the combination of the slots and the poles of the fractional-slot PM machines.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TEC.2008.2006557</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0885-8969 |
ispartof | IEEE transactions on energy conversion, 2009-06, Vol.24 (2), p.323-328 |
issn | 0885-8969 1558-0059 |
language | eng |
recordid | cdi_ieee_primary_4757261 |
source | IEEE Xplore (Online service) |
subjects | Air gaps Analytical models Conducting materials Current density Density Direct power generation Flux Geometry Harmonics Permanent-magnet (PM) machines PM motors Poles Process design Ripples rotor losses Rotors Solids Torque variable-speed drives |
title | Impact of MMF Space Harmonic on Rotor Losses in Fractional-Slot Permanent-Magnet Machines |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T19%3A02%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20MMF%20Space%20Harmonic%20on%20Rotor%20Losses%20in%20Fractional-Slot%20Permanent-Magnet%20Machines&rft.jtitle=IEEE%20transactions%20on%20energy%20conversion&rft.au=Bianchi,%20N.&rft.date=2009-06-01&rft.volume=24&rft.issue=2&rft.spage=323&rft.epage=328&rft.pages=323-328&rft.issn=0885-8969&rft.eissn=1558-0059&rft.coden=ITCNE4&rft_id=info:doi/10.1109/TEC.2008.2006557&rft_dat=%3Cproquest_ieee_%3E34622065%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c353t-f198f1a31aee302857374bfc2ab9d33a163d8b281875f8d11cfa630075c2d8c53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=858676429&rft_id=info:pmid/&rft_ieee_id=4757261&rfr_iscdi=true |