Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods

In PET/CT thoracic imaging, respiratory motion has been reported as a limiting factor reducing image quality and biasing lesion volume measurement. One solution consists in performing respiratory gated PET acquisitions. The aim of this study was to evaluate the impact of respiratory gating on Monte-...

Full description

Saved in:
Bibliographic Details
Main Authors: Vauclin, Sebastien, Hapdey, Sebastien, Michel, Christian, Rebani, Hafid, Buvat, Irene, Edet-Sanson, Agathe, Doyeux, Kaya, Gardin, Isabelle, Vera, Pierre
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 4053
container_issue
container_start_page 4050
container_title
container_volume
creator Vauclin, Sebastien
Hapdey, Sebastien
Michel, Christian
Rebani, Hafid
Buvat, Irene
Edet-Sanson, Agathe
Doyeux, Kaya
Gardin, Isabelle
Vera, Pierre
description In PET/CT thoracic imaging, respiratory motion has been reported as a limiting factor reducing image quality and biasing lesion volume measurement. One solution consists in performing respiratory gated PET acquisitions. The aim of this study was to evaluate the impact of respiratory gating on Monte-Carlo realistic PET data, simulated using the 4D-NCAT numerical phantom on the GATE platform. To obtain reconstructed images as close as possible to those obtained in clinical conditions, a particular attention was paid to apply the same type of reconstruction and correction processes on the simulated data as on real clinical ones. The whole set of simulations required a CPU time of 140 000 h generating 1.5 To of data, including simulations of 147 respiratory gated and 49 ungated thoracic exams. Comparison of the displacement volume (DV) measurements using conventional PET acquisitions versus respiratory gated acquisitions was performed, using an automatic iterative segmentation method and a fixed 40% threshold. The segmentation of gated and ungated frames using the 40% fixed threshold needed time consuming initial manual exclusion of noisy structures and so not considered as an automatic method. This step was not necessary when the automatic iterative method was used. Accuracy on DV measurement using the automatic approach was largely improved on gated compared to ungated images. This improved accuracy might have a significant impact when patient treatment is performed using ungated external radiotherapy.
doi_str_mv 10.1109/NSSMIC.2008.4774174
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4774174</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4774174</ieee_id><sourcerecordid>4774174</sourcerecordid><originalsourceid>FETCH-ieee_primary_47741743</originalsourceid><addsrcrecordid>eNp9j8tOwzAQRV0eEinwBd3MDyTYzgSn69AAiyKkdl9Z6oS6iuPK4yD172lRJXasrnSOzuIKMVOyUErOnz5Wq-V7U2gp6wKNQWVwIqYKNaI2qpJXItOVMbms9fz6T6C-EZk6wbx8rvBOTJn3UmpZImbCLcOQCBob-wDs_Njb5MLAEDqIxAcXbQrxCF820RZU3ebtyyt8LtbQhQhpR2CZidnTkM7Nd-hHT-DJ8hjpl3pKu7DlB3Hb2Z7p8bL3YtYu1s1b7ohoc4jO23jcXH6V_9sfuHNNLQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Vauclin, Sebastien ; Hapdey, Sebastien ; Michel, Christian ; Rebani, Hafid ; Buvat, Irene ; Edet-Sanson, Agathe ; Doyeux, Kaya ; Gardin, Isabelle ; Vera, Pierre</creator><creatorcontrib>Vauclin, Sebastien ; Hapdey, Sebastien ; Michel, Christian ; Rebani, Hafid ; Buvat, Irene ; Edet-Sanson, Agathe ; Doyeux, Kaya ; Gardin, Isabelle ; Vera, Pierre</creatorcontrib><description>In PET/CT thoracic imaging, respiratory motion has been reported as a limiting factor reducing image quality and biasing lesion volume measurement. One solution consists in performing respiratory gated PET acquisitions. The aim of this study was to evaluate the impact of respiratory gating on Monte-Carlo realistic PET data, simulated using the 4D-NCAT numerical phantom on the GATE platform. To obtain reconstructed images as close as possible to those obtained in clinical conditions, a particular attention was paid to apply the same type of reconstruction and correction processes on the simulated data as on real clinical ones. The whole set of simulations required a CPU time of 140 000 h generating 1.5 To of data, including simulations of 147 respiratory gated and 49 ungated thoracic exams. Comparison of the displacement volume (DV) measurements using conventional PET acquisitions versus respiratory gated acquisitions was performed, using an automatic iterative segmentation method and a fixed 40% threshold. The segmentation of gated and ungated frames using the 40% fixed threshold needed time consuming initial manual exclusion of noisy structures and so not considered as an automatic method. This step was not necessary when the automatic iterative method was used. Accuracy on DV measurement using the automatic approach was largely improved on gated compared to ungated images. This improved accuracy might have a significant impact when patient treatment is performed using ungated external radiotherapy.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1424427142</identifier><identifier>ISBN: 9781424427147</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1424427150</identifier><identifier>EISBN: 9781424427154</identifier><identifier>DOI: 10.1109/NSSMIC.2008.4774174</identifier><language>eng</language><publisher>IEEE</publisher><subject>Computed tomography ; Displacement measurement ; Image quality ; Image reconstruction ; image segmentation ; Imaging phantoms ; Iterative methods ; Lesions ; Monte Carlo simulation ; Performance evaluation ; PET ; Positron emission tomography ; Volume measurement</subject><ispartof>2008 IEEE Nuclear Science Symposium Conference Record, 2008, p.4050-4053</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4774174$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54530,54895,54907</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4774174$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Vauclin, Sebastien</creatorcontrib><creatorcontrib>Hapdey, Sebastien</creatorcontrib><creatorcontrib>Michel, Christian</creatorcontrib><creatorcontrib>Rebani, Hafid</creatorcontrib><creatorcontrib>Buvat, Irene</creatorcontrib><creatorcontrib>Edet-Sanson, Agathe</creatorcontrib><creatorcontrib>Doyeux, Kaya</creatorcontrib><creatorcontrib>Gardin, Isabelle</creatorcontrib><creatorcontrib>Vera, Pierre</creatorcontrib><title>Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods</title><title>2008 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>In PET/CT thoracic imaging, respiratory motion has been reported as a limiting factor reducing image quality and biasing lesion volume measurement. One solution consists in performing respiratory gated PET acquisitions. The aim of this study was to evaluate the impact of respiratory gating on Monte-Carlo realistic PET data, simulated using the 4D-NCAT numerical phantom on the GATE platform. To obtain reconstructed images as close as possible to those obtained in clinical conditions, a particular attention was paid to apply the same type of reconstruction and correction processes on the simulated data as on real clinical ones. The whole set of simulations required a CPU time of 140 000 h generating 1.5 To of data, including simulations of 147 respiratory gated and 49 ungated thoracic exams. Comparison of the displacement volume (DV) measurements using conventional PET acquisitions versus respiratory gated acquisitions was performed, using an automatic iterative segmentation method and a fixed 40% threshold. The segmentation of gated and ungated frames using the 40% fixed threshold needed time consuming initial manual exclusion of noisy structures and so not considered as an automatic method. This step was not necessary when the automatic iterative method was used. Accuracy on DV measurement using the automatic approach was largely improved on gated compared to ungated images. This improved accuracy might have a significant impact when patient treatment is performed using ungated external radiotherapy.</description><subject>Computed tomography</subject><subject>Displacement measurement</subject><subject>Image quality</subject><subject>Image reconstruction</subject><subject>image segmentation</subject><subject>Imaging phantoms</subject><subject>Iterative methods</subject><subject>Lesions</subject><subject>Monte Carlo simulation</subject><subject>Performance evaluation</subject><subject>PET</subject><subject>Positron emission tomography</subject><subject>Volume measurement</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1424427142</isbn><isbn>9781424427147</isbn><isbn>1424427150</isbn><isbn>9781424427154</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNp9j8tOwzAQRV0eEinwBd3MDyTYzgSn69AAiyKkdl9Z6oS6iuPK4yD172lRJXasrnSOzuIKMVOyUErOnz5Wq-V7U2gp6wKNQWVwIqYKNaI2qpJXItOVMbms9fz6T6C-EZk6wbx8rvBOTJn3UmpZImbCLcOQCBob-wDs_Njb5MLAEDqIxAcXbQrxCF820RZU3ebtyyt8LtbQhQhpR2CZidnTkM7Nd-hHT-DJ8hjpl3pKu7DlB3Hb2Z7p8bL3YtYu1s1b7ohoc4jO23jcXH6V_9sfuHNNLQ</recordid><startdate>200810</startdate><enddate>200810</enddate><creator>Vauclin, Sebastien</creator><creator>Hapdey, Sebastien</creator><creator>Michel, Christian</creator><creator>Rebani, Hafid</creator><creator>Buvat, Irene</creator><creator>Edet-Sanson, Agathe</creator><creator>Doyeux, Kaya</creator><creator>Gardin, Isabelle</creator><creator>Vera, Pierre</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200810</creationdate><title>Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods</title><author>Vauclin, Sebastien ; Hapdey, Sebastien ; Michel, Christian ; Rebani, Hafid ; Buvat, Irene ; Edet-Sanson, Agathe ; Doyeux, Kaya ; Gardin, Isabelle ; Vera, Pierre</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ieee_primary_47741743</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Computed tomography</topic><topic>Displacement measurement</topic><topic>Image quality</topic><topic>Image reconstruction</topic><topic>image segmentation</topic><topic>Imaging phantoms</topic><topic>Iterative methods</topic><topic>Lesions</topic><topic>Monte Carlo simulation</topic><topic>Performance evaluation</topic><topic>PET</topic><topic>Positron emission tomography</topic><topic>Volume measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Vauclin, Sebastien</creatorcontrib><creatorcontrib>Hapdey, Sebastien</creatorcontrib><creatorcontrib>Michel, Christian</creatorcontrib><creatorcontrib>Rebani, Hafid</creatorcontrib><creatorcontrib>Buvat, Irene</creatorcontrib><creatorcontrib>Edet-Sanson, Agathe</creatorcontrib><creatorcontrib>Doyeux, Kaya</creatorcontrib><creatorcontrib>Gardin, Isabelle</creatorcontrib><creatorcontrib>Vera, Pierre</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Vauclin, Sebastien</au><au>Hapdey, Sebastien</au><au>Michel, Christian</au><au>Rebani, Hafid</au><au>Buvat, Irene</au><au>Edet-Sanson, Agathe</au><au>Doyeux, Kaya</au><au>Gardin, Isabelle</au><au>Vera, Pierre</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods</atitle><btitle>2008 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2008-10</date><risdate>2008</risdate><spage>4050</spage><epage>4053</epage><pages>4050-4053</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1424427142</isbn><isbn>9781424427147</isbn><eisbn>1424427150</eisbn><eisbn>9781424427154</eisbn><abstract>In PET/CT thoracic imaging, respiratory motion has been reported as a limiting factor reducing image quality and biasing lesion volume measurement. One solution consists in performing respiratory gated PET acquisitions. The aim of this study was to evaluate the impact of respiratory gating on Monte-Carlo realistic PET data, simulated using the 4D-NCAT numerical phantom on the GATE platform. To obtain reconstructed images as close as possible to those obtained in clinical conditions, a particular attention was paid to apply the same type of reconstruction and correction processes on the simulated data as on real clinical ones. The whole set of simulations required a CPU time of 140 000 h generating 1.5 To of data, including simulations of 147 respiratory gated and 49 ungated thoracic exams. Comparison of the displacement volume (DV) measurements using conventional PET acquisitions versus respiratory gated acquisitions was performed, using an automatic iterative segmentation method and a fixed 40% threshold. The segmentation of gated and ungated frames using the 40% fixed threshold needed time consuming initial manual exclusion of noisy structures and so not considered as an automatic method. This step was not necessary when the automatic iterative method was used. Accuracy on DV measurement using the automatic approach was largely improved on gated compared to ungated images. This improved accuracy might have a significant impact when patient treatment is performed using ungated external radiotherapy.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2008.4774174</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2008 IEEE Nuclear Science Symposium Conference Record, 2008, p.4050-4053
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_4774174
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Computed tomography
Displacement measurement
Image quality
Image reconstruction
image segmentation
Imaging phantoms
Iterative methods
Lesions
Monte Carlo simulation
Performance evaluation
PET
Positron emission tomography
Volume measurement
title Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-23T19%3A32%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Monte%20Carlo%20simulations%20of%20respiratory%20gated%2018F-FDG%20PET%20for%20the%20assessment%20of%20volume%20measurement%20methods&rft.btitle=2008%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Vauclin,%20Sebastien&rft.date=2008-10&rft.spage=4050&rft.epage=4053&rft.pages=4050-4053&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1424427142&rft.isbn_list=9781424427147&rft_id=info:doi/10.1109/NSSMIC.2008.4774174&rft.eisbn=1424427150&rft.eisbn_list=9781424427154&rft_dat=%3Cieee_6IE%3E4774174%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-ieee_primary_47741743%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4774174&rfr_iscdi=true