Loading…
Point source resolution performance of a germanium Compton camera
One of the critical performance parameters for a Compton camera imager is the point source location accuracy. This paper describes analysis of both experimental and simulated data to evaluate the point source resolving power of a germanium Compton camera imager. The experimental data are taken from...
Saved in:
Published in: | IEEE transactions on nuclear science 1996-06, Vol.43 (3), p.1832-1836 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3 |
container_end_page | 1836 |
container_issue | 3 |
container_start_page | 1832 |
container_title | IEEE transactions on nuclear science |
container_volume | 43 |
creator | Haskins, P.S. McKisson, J.E. Neelands, K.C. Henderson, D.P. |
description | One of the critical performance parameters for a Compton camera imager is the point source location accuracy. This paper describes analysis of both experimental and simulated data to evaluate the point source resolving power of a germanium Compton camera imager. The experimental data are taken from a set of experiments performed in 1993 at Naval Research Laboratory. Subsequent design studies have utilized Monte Carlo simulations to predict the performance parameters for a number of detector geometries. Presented in this paper are the results from one of those configurations. |
doi_str_mv | 10.1109/23.507231 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_507231</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>507231</ieee_id><sourcerecordid>28483724</sourcerecordid><originalsourceid>FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3</originalsourceid><addsrcrecordid>eNo90DFLxTAQB_AgCtang6tTJ8Ghz0vStMn4KD4VHuigc0jTi1Tapibt4Le3jz7khuN_9-OGI-SWwpZSUI-MbwWUjNMzklAhZEZFKc9JAkBlpnKlLslVjN9LzAWIhOzefTtMafRzsJgGjL6bp9YP6YjB-dCbYRl7l5r0C4-pnfu08v04LcSaHoO5JhfOdBFvTn1DPvdPH9VLdnh7fq12h8xy4FOW27o2DaNGlbQGUFJCUUveAC2WkoUQDq1panRNI6lgeQFopKOqZCBqafmG3K93x-B_ZoyT7ttosevMgH6Omslc8pLlC3xYoQ0-xoBOj6HtTfjVFPTxSZpxvT5psXerbRHx352Wf52LYWg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28483724</pqid></control><display><type>article</type><title>Point source resolution performance of a germanium Compton camera</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Haskins, P.S. ; McKisson, J.E. ; Neelands, K.C. ; Henderson, D.P.</creator><creatorcontrib>Haskins, P.S. ; McKisson, J.E. ; Neelands, K.C. ; Henderson, D.P.</creatorcontrib><description>One of the critical performance parameters for a Compton camera imager is the point source location accuracy. This paper describes analysis of both experimental and simulated data to evaluate the point source resolving power of a germanium Compton camera imager. The experimental data are taken from a set of experiments performed in 1993 at Naval Research Laboratory. Subsequent design studies have utilized Monte Carlo simulations to predict the performance parameters for a number of detector geometries. Presented in this paper are the results from one of those configurations.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/23.507231</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Cameras ; Detectors ; Germanium ; Image reconstruction ; Laboratories ; Position measurement ; Radiofrequency interference ; Scattering parameters ; Surface reconstruction ; Uncertainty</subject><ispartof>IEEE transactions on nuclear science, 1996-06, Vol.43 (3), p.1832-1836</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3</citedby><cites>FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/507231$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,54777</link.rule.ids></links><search><creatorcontrib>Haskins, P.S.</creatorcontrib><creatorcontrib>McKisson, J.E.</creatorcontrib><creatorcontrib>Neelands, K.C.</creatorcontrib><creatorcontrib>Henderson, D.P.</creatorcontrib><title>Point source resolution performance of a germanium Compton camera</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>One of the critical performance parameters for a Compton camera imager is the point source location accuracy. This paper describes analysis of both experimental and simulated data to evaluate the point source resolving power of a germanium Compton camera imager. The experimental data are taken from a set of experiments performed in 1993 at Naval Research Laboratory. Subsequent design studies have utilized Monte Carlo simulations to predict the performance parameters for a number of detector geometries. Presented in this paper are the results from one of those configurations.</description><subject>Cameras</subject><subject>Detectors</subject><subject>Germanium</subject><subject>Image reconstruction</subject><subject>Laboratories</subject><subject>Position measurement</subject><subject>Radiofrequency interference</subject><subject>Scattering parameters</subject><subject>Surface reconstruction</subject><subject>Uncertainty</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNo90DFLxTAQB_AgCtang6tTJ8Ghz0vStMn4KD4VHuigc0jTi1Tapibt4Le3jz7khuN_9-OGI-SWwpZSUI-MbwWUjNMzklAhZEZFKc9JAkBlpnKlLslVjN9LzAWIhOzefTtMafRzsJgGjL6bp9YP6YjB-dCbYRl7l5r0C4-pnfu08v04LcSaHoO5JhfOdBFvTn1DPvdPH9VLdnh7fq12h8xy4FOW27o2DaNGlbQGUFJCUUveAC2WkoUQDq1panRNI6lgeQFopKOqZCBqafmG3K93x-B_ZoyT7ttosevMgH6Omslc8pLlC3xYoQ0-xoBOj6HtTfjVFPTxSZpxvT5psXerbRHx352Wf52LYWg</recordid><startdate>19960601</startdate><enddate>19960601</enddate><creator>Haskins, P.S.</creator><creator>McKisson, J.E.</creator><creator>Neelands, K.C.</creator><creator>Henderson, D.P.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19960601</creationdate><title>Point source resolution performance of a germanium Compton camera</title><author>Haskins, P.S. ; McKisson, J.E. ; Neelands, K.C. ; Henderson, D.P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Cameras</topic><topic>Detectors</topic><topic>Germanium</topic><topic>Image reconstruction</topic><topic>Laboratories</topic><topic>Position measurement</topic><topic>Radiofrequency interference</topic><topic>Scattering parameters</topic><topic>Surface reconstruction</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Haskins, P.S.</creatorcontrib><creatorcontrib>McKisson, J.E.</creatorcontrib><creatorcontrib>Neelands, K.C.</creatorcontrib><creatorcontrib>Henderson, D.P.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Haskins, P.S.</au><au>McKisson, J.E.</au><au>Neelands, K.C.</au><au>Henderson, D.P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Point source resolution performance of a germanium Compton camera</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>1996-06-01</date><risdate>1996</risdate><volume>43</volume><issue>3</issue><spage>1832</spage><epage>1836</epage><pages>1832-1836</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>One of the critical performance parameters for a Compton camera imager is the point source location accuracy. This paper describes analysis of both experimental and simulated data to evaluate the point source resolving power of a germanium Compton camera imager. The experimental data are taken from a set of experiments performed in 1993 at Naval Research Laboratory. Subsequent design studies have utilized Monte Carlo simulations to predict the performance parameters for a number of detector geometries. Presented in this paper are the results from one of those configurations.</abstract><pub>IEEE</pub><doi>10.1109/23.507231</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0018-9499 |
ispartof | IEEE transactions on nuclear science, 1996-06, Vol.43 (3), p.1832-1836 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_ieee_primary_507231 |
source | IEEE Electronic Library (IEL) Journals |
subjects | Cameras Detectors Germanium Image reconstruction Laboratories Position measurement Radiofrequency interference Scattering parameters Surface reconstruction Uncertainty |
title | Point source resolution performance of a germanium Compton camera |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T16%3A55%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Point%20source%20resolution%20performance%20of%20a%20germanium%20Compton%20camera&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Haskins,%20P.S.&rft.date=1996-06-01&rft.volume=43&rft.issue=3&rft.spage=1832&rft.epage=1836&rft.pages=1832-1836&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/23.507231&rft_dat=%3Cproquest_ieee_%3E28483724%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c303t-4cbbad21a971b0098806b83d0161618655fecadbefdd8152460ea8f197205b8c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=28483724&rft_id=info:pmid/&rft_ieee_id=507231&rfr_iscdi=true |