New resonant pole inverter for battery fed brushless dc motor drive
The brushless DC motor (BLDC) has been widely used in industrial applications because of its low inertia, fast response, high power density, high reliability, and maintenance-free reputation. They are usually supplied by a hard switching PWM inverter, with rather high switching loss. Therefore large...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 356 |
container_issue | |
container_start_page | 352 |
container_title | |
container_volume | |
creator | Shahbazi, M.M. Madani, S.M. Ebrahimi, A. |
description | The brushless DC motor (BLDC) has been widely used in industrial applications because of its low inertia, fast response, high power density, high reliability, and maintenance-free reputation. They are usually supplied by a hard switching PWM inverter, with rather high switching loss. Therefore large heat-sinks are required for dissipation of this switching loss which increase the volume and weight of the drive system. In order to reduce switching losses, many soft switching inverters have been designed by several researchers. Soft-switching circuits has other problems, such as excessive voltage stress, non-full PWM control and complexity in control scheme or implementation. This paper presents a simple soft switch inverter proposed which is applicable to battery-fed BLDC drive systems. This inverter has low switching-power loss, low voltage stress on the main switches, simple control scheme and easy to implement. After analytical analysis simulation results are shown to verify the theoretical analysis. |
doi_str_mv | 10.1109/IEMDC.2009.5075229 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5075229</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5075229</ieee_id><sourcerecordid>5075229</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-f182daafebe24fabf13082139533b239847003135a8a394e57e5154f2aa1297f3</originalsourceid><addsrcrecordid>eNpVUMtOwzAQNEKVgJIfgIt_IMXrh-w9olCgUoELnKsNWYugNKnsUNS_J4he2MvM7oxGoxXiCtQCQOHNavl0Vy20Urhwyjut8UQU6ANYba3V0-H03w5uJi5-7agA0Z2JIudPNY11RmE4F9Uzf8vEeeipH-Vu6Fi2_Z7TyEnGIcmaxokeZORG1ukrf3Scs2ze5XYYJ7lJ7Z4vxSxSl7k44ly83S9fq8dy_fKwqm7XZQvejWWEoBuiyDVrG6mOYFTQYNAZU2uDwXqlDBhHgQxadp6n_jZqItDoo5mL67_clpk3u9RuKR02xz-YHyMxTfA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>New resonant pole inverter for battery fed brushless dc motor drive</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Shahbazi, M.M. ; Madani, S.M. ; Ebrahimi, A.</creator><creatorcontrib>Shahbazi, M.M. ; Madani, S.M. ; Ebrahimi, A.</creatorcontrib><description>The brushless DC motor (BLDC) has been widely used in industrial applications because of its low inertia, fast response, high power density, high reliability, and maintenance-free reputation. They are usually supplied by a hard switching PWM inverter, with rather high switching loss. Therefore large heat-sinks are required for dissipation of this switching loss which increase the volume and weight of the drive system. In order to reduce switching losses, many soft switching inverters have been designed by several researchers. Soft-switching circuits has other problems, such as excessive voltage stress, non-full PWM control and complexity in control scheme or implementation. This paper presents a simple soft switch inverter proposed which is applicable to battery-fed BLDC drive systems. This inverter has low switching-power loss, low voltage stress on the main switches, simple control scheme and easy to implement. After analytical analysis simulation results are shown to verify the theoretical analysis.</description><identifier>ISBN: 9781424442515</identifier><identifier>ISBN: 1424442516</identifier><identifier>EISBN: 9781424442522</identifier><identifier>EISBN: 1424442524</identifier><identifier>DOI: 10.1109/IEMDC.2009.5075229</identifier><identifier>LCCN: 2009901995</identifier><language>eng</language><publisher>IEEE</publisher><subject>Batteries ; Brushless DC motors ; Power system reliability ; Pulse width modulation ; Pulse width modulation inverters ; Resonance ; Stress control ; Switches ; Switching loss ; Voltage control</subject><ispartof>2009 IEEE International Electric Machines and Drives Conference, 2009, p.352-356</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5075229$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5075229$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Shahbazi, M.M.</creatorcontrib><creatorcontrib>Madani, S.M.</creatorcontrib><creatorcontrib>Ebrahimi, A.</creatorcontrib><title>New resonant pole inverter for battery fed brushless dc motor drive</title><title>2009 IEEE International Electric Machines and Drives Conference</title><addtitle>IEMDC</addtitle><description>The brushless DC motor (BLDC) has been widely used in industrial applications because of its low inertia, fast response, high power density, high reliability, and maintenance-free reputation. They are usually supplied by a hard switching PWM inverter, with rather high switching loss. Therefore large heat-sinks are required for dissipation of this switching loss which increase the volume and weight of the drive system. In order to reduce switching losses, many soft switching inverters have been designed by several researchers. Soft-switching circuits has other problems, such as excessive voltage stress, non-full PWM control and complexity in control scheme or implementation. This paper presents a simple soft switch inverter proposed which is applicable to battery-fed BLDC drive systems. This inverter has low switching-power loss, low voltage stress on the main switches, simple control scheme and easy to implement. After analytical analysis simulation results are shown to verify the theoretical analysis.</description><subject>Batteries</subject><subject>Brushless DC motors</subject><subject>Power system reliability</subject><subject>Pulse width modulation</subject><subject>Pulse width modulation inverters</subject><subject>Resonance</subject><subject>Stress control</subject><subject>Switches</subject><subject>Switching loss</subject><subject>Voltage control</subject><isbn>9781424442515</isbn><isbn>1424442516</isbn><isbn>9781424442522</isbn><isbn>1424442524</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNpVUMtOwzAQNEKVgJIfgIt_IMXrh-w9olCgUoELnKsNWYugNKnsUNS_J4he2MvM7oxGoxXiCtQCQOHNavl0Vy20Urhwyjut8UQU6ANYba3V0-H03w5uJi5-7agA0Z2JIudPNY11RmE4F9Uzf8vEeeipH-Vu6Fi2_Z7TyEnGIcmaxokeZORG1ukrf3Scs2ze5XYYJ7lJ7Z4vxSxSl7k44ly83S9fq8dy_fKwqm7XZQvejWWEoBuiyDVrG6mOYFTQYNAZU2uDwXqlDBhHgQxadp6n_jZqItDoo5mL67_clpk3u9RuKR02xz-YHyMxTfA</recordid><startdate>200905</startdate><enddate>200905</enddate><creator>Shahbazi, M.M.</creator><creator>Madani, S.M.</creator><creator>Ebrahimi, A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>200905</creationdate><title>New resonant pole inverter for battery fed brushless dc motor drive</title><author>Shahbazi, M.M. ; Madani, S.M. ; Ebrahimi, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-f182daafebe24fabf13082139533b239847003135a8a394e57e5154f2aa1297f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Batteries</topic><topic>Brushless DC motors</topic><topic>Power system reliability</topic><topic>Pulse width modulation</topic><topic>Pulse width modulation inverters</topic><topic>Resonance</topic><topic>Stress control</topic><topic>Switches</topic><topic>Switching loss</topic><topic>Voltage control</topic><toplevel>online_resources</toplevel><creatorcontrib>Shahbazi, M.M.</creatorcontrib><creatorcontrib>Madani, S.M.</creatorcontrib><creatorcontrib>Ebrahimi, A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Shahbazi, M.M.</au><au>Madani, S.M.</au><au>Ebrahimi, A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>New resonant pole inverter for battery fed brushless dc motor drive</atitle><btitle>2009 IEEE International Electric Machines and Drives Conference</btitle><stitle>IEMDC</stitle><date>2009-05</date><risdate>2009</risdate><spage>352</spage><epage>356</epage><pages>352-356</pages><isbn>9781424442515</isbn><isbn>1424442516</isbn><eisbn>9781424442522</eisbn><eisbn>1424442524</eisbn><abstract>The brushless DC motor (BLDC) has been widely used in industrial applications because of its low inertia, fast response, high power density, high reliability, and maintenance-free reputation. They are usually supplied by a hard switching PWM inverter, with rather high switching loss. Therefore large heat-sinks are required for dissipation of this switching loss which increase the volume and weight of the drive system. In order to reduce switching losses, many soft switching inverters have been designed by several researchers. Soft-switching circuits has other problems, such as excessive voltage stress, non-full PWM control and complexity in control scheme or implementation. This paper presents a simple soft switch inverter proposed which is applicable to battery-fed BLDC drive systems. This inverter has low switching-power loss, low voltage stress on the main switches, simple control scheme and easy to implement. After analytical analysis simulation results are shown to verify the theoretical analysis.</abstract><pub>IEEE</pub><doi>10.1109/IEMDC.2009.5075229</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781424442515 |
ispartof | 2009 IEEE International Electric Machines and Drives Conference, 2009, p.352-356 |
issn | |
language | eng |
recordid | cdi_ieee_primary_5075229 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Batteries Brushless DC motors Power system reliability Pulse width modulation Pulse width modulation inverters Resonance Stress control Switches Switching loss Voltage control |
title | New resonant pole inverter for battery fed brushless dc motor drive |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T02%3A04%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=New%20resonant%20pole%20inverter%20for%20battery%20fed%20brushless%20dc%20motor%20drive&rft.btitle=2009%20IEEE%20International%20Electric%20Machines%20and%20Drives%20Conference&rft.au=Shahbazi,%20M.M.&rft.date=2009-05&rft.spage=352&rft.epage=356&rft.pages=352-356&rft.isbn=9781424442515&rft.isbn_list=1424442516&rft_id=info:doi/10.1109/IEMDC.2009.5075229&rft.eisbn=9781424442522&rft.eisbn_list=1424442524&rft_dat=%3Cieee_6IE%3E5075229%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-f182daafebe24fabf13082139533b239847003135a8a394e57e5154f2aa1297f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5075229&rfr_iscdi=true |