Liquid encapsulant stress variations as measured with the ATCO4 assembly test chip

We have examined the use of the ATCO4 piezoresistive Assembly Test Chip to measure the mechanical surface stresses produced by liquid encapsulation of die mounted directly on ceramic substrates. In our experiment, two groups of parts, each with about 70 samples, were encapsulated with two different...

Full description

Saved in:
Bibliographic Details
Main Authors: Sweet, J.N., Peterson, D.W., Emerson, J.A., Mitchell, R.T.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 304
container_issue
container_start_page 300
container_title
container_volume
creator Sweet, J.N.
Peterson, D.W.
Emerson, J.A.
Mitchell, R.T.
description We have examined the use of the ATCO4 piezoresistive Assembly Test Chip to measure the mechanical surface stresses produced by liquid encapsulation of die mounted directly on ceramic substrates. In our experiment, two groups of parts, each with about 70 samples, were encapsulated with two different materials, one a standard and one a low stress formulation. Results are presented for the measured stress components; /spl sigma//sub xx/-/spl sigma//sub zz/, /spl sigma//sub xy/, and /spl sigma//sub xx/-/spl sigma//sub yy/. We observe an /spl ap/20% reduction in the compressive stress between the normal stress and low stress materials, and a small but measurable difference in the average in-plane shearing stress. This experiment demonstrates the ability to resolve stress differences produced by different encapsulants and provides guidelines for selecting appropriate sample sizes.
doi_str_mv 10.1109/ECTC.1995.514399
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_514399</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>514399</ieee_id><sourcerecordid>514399</sourcerecordid><originalsourceid>FETCH-ieee_primary_5143993</originalsourceid><addsrcrecordid>eNp9jsEKgkAURQciKMp9tHo_kM00ms4yxGgRBOFeJn3hhJrNG4v-PqHWXQ6cxdlcxhaC-0JwtU6TLPGFUqEfikAqNWKeimI-IDeR3MYT5hHd-LAgDGXAp-x8NI_elIBtoTvqa906IGeRCJ7aGu3MvSXQBA1q6i2W8DKuAlch7LLkFAyJsLnUb3BIDorKdHM2vuqa0Pt5xpb7NEsOK4OIeWdNo-07_x6Uf-MHZik_hg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Liquid encapsulant stress variations as measured with the ATCO4 assembly test chip</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Sweet, J.N. ; Peterson, D.W. ; Emerson, J.A. ; Mitchell, R.T.</creator><creatorcontrib>Sweet, J.N. ; Peterson, D.W. ; Emerson, J.A. ; Mitchell, R.T.</creatorcontrib><description>We have examined the use of the ATCO4 piezoresistive Assembly Test Chip to measure the mechanical surface stresses produced by liquid encapsulation of die mounted directly on ceramic substrates. In our experiment, two groups of parts, each with about 70 samples, were encapsulated with two different materials, one a standard and one a low stress formulation. Results are presented for the measured stress components; /spl sigma//sub xx/-/spl sigma//sub zz/, /spl sigma//sub xy/, and /spl sigma//sub xx/-/spl sigma//sub yy/. We observe an /spl ap/20% reduction in the compressive stress between the normal stress and low stress materials, and a small but measurable difference in the average in-plane shearing stress. This experiment demonstrates the ability to resolve stress differences produced by different encapsulants and provides guidelines for selecting appropriate sample sizes.</description><identifier>ISBN: 9780780327368</identifier><identifier>ISBN: 0780327365</identifier><identifier>DOI: 10.1109/ECTC.1995.514399</identifier><language>eng</language><publisher>IEEE</publisher><subject>Assembly ; Ceramics ; Compressive stress ; Encapsulation ; Mechanical variables measurement ; Piezoresistance ; Semiconductor device measurement ; Shearing ; Stress measurement ; Testing</subject><ispartof>1995 Proceedings. 45th Electronic Components and Technology Conference, 1995, p.300-304</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/514399$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/514399$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Sweet, J.N.</creatorcontrib><creatorcontrib>Peterson, D.W.</creatorcontrib><creatorcontrib>Emerson, J.A.</creatorcontrib><creatorcontrib>Mitchell, R.T.</creatorcontrib><title>Liquid encapsulant stress variations as measured with the ATCO4 assembly test chip</title><title>1995 Proceedings. 45th Electronic Components and Technology Conference</title><addtitle>ECTC</addtitle><description>We have examined the use of the ATCO4 piezoresistive Assembly Test Chip to measure the mechanical surface stresses produced by liquid encapsulation of die mounted directly on ceramic substrates. In our experiment, two groups of parts, each with about 70 samples, were encapsulated with two different materials, one a standard and one a low stress formulation. Results are presented for the measured stress components; /spl sigma//sub xx/-/spl sigma//sub zz/, /spl sigma//sub xy/, and /spl sigma//sub xx/-/spl sigma//sub yy/. We observe an /spl ap/20% reduction in the compressive stress between the normal stress and low stress materials, and a small but measurable difference in the average in-plane shearing stress. This experiment demonstrates the ability to resolve stress differences produced by different encapsulants and provides guidelines for selecting appropriate sample sizes.</description><subject>Assembly</subject><subject>Ceramics</subject><subject>Compressive stress</subject><subject>Encapsulation</subject><subject>Mechanical variables measurement</subject><subject>Piezoresistance</subject><subject>Semiconductor device measurement</subject><subject>Shearing</subject><subject>Stress measurement</subject><subject>Testing</subject><isbn>9780780327368</isbn><isbn>0780327365</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1995</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNp9jsEKgkAURQciKMp9tHo_kM00ms4yxGgRBOFeJn3hhJrNG4v-PqHWXQ6cxdlcxhaC-0JwtU6TLPGFUqEfikAqNWKeimI-IDeR3MYT5hHd-LAgDGXAp-x8NI_elIBtoTvqa906IGeRCJ7aGu3MvSXQBA1q6i2W8DKuAlch7LLkFAyJsLnUb3BIDorKdHM2vuqa0Pt5xpb7NEsOK4OIeWdNo-07_x6Uf-MHZik_hg</recordid><startdate>1995</startdate><enddate>1995</enddate><creator>Sweet, J.N.</creator><creator>Peterson, D.W.</creator><creator>Emerson, J.A.</creator><creator>Mitchell, R.T.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1995</creationdate><title>Liquid encapsulant stress variations as measured with the ATCO4 assembly test chip</title><author>Sweet, J.N. ; Peterson, D.W. ; Emerson, J.A. ; Mitchell, R.T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ieee_primary_5143993</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Assembly</topic><topic>Ceramics</topic><topic>Compressive stress</topic><topic>Encapsulation</topic><topic>Mechanical variables measurement</topic><topic>Piezoresistance</topic><topic>Semiconductor device measurement</topic><topic>Shearing</topic><topic>Stress measurement</topic><topic>Testing</topic><toplevel>online_resources</toplevel><creatorcontrib>Sweet, J.N.</creatorcontrib><creatorcontrib>Peterson, D.W.</creatorcontrib><creatorcontrib>Emerson, J.A.</creatorcontrib><creatorcontrib>Mitchell, R.T.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore (Online service)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sweet, J.N.</au><au>Peterson, D.W.</au><au>Emerson, J.A.</au><au>Mitchell, R.T.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Liquid encapsulant stress variations as measured with the ATCO4 assembly test chip</atitle><btitle>1995 Proceedings. 45th Electronic Components and Technology Conference</btitle><stitle>ECTC</stitle><date>1995</date><risdate>1995</risdate><spage>300</spage><epage>304</epage><pages>300-304</pages><isbn>9780780327368</isbn><isbn>0780327365</isbn><abstract>We have examined the use of the ATCO4 piezoresistive Assembly Test Chip to measure the mechanical surface stresses produced by liquid encapsulation of die mounted directly on ceramic substrates. In our experiment, two groups of parts, each with about 70 samples, were encapsulated with two different materials, one a standard and one a low stress formulation. Results are presented for the measured stress components; /spl sigma//sub xx/-/spl sigma//sub zz/, /spl sigma//sub xy/, and /spl sigma//sub xx/-/spl sigma//sub yy/. We observe an /spl ap/20% reduction in the compressive stress between the normal stress and low stress materials, and a small but measurable difference in the average in-plane shearing stress. This experiment demonstrates the ability to resolve stress differences produced by different encapsulants and provides guidelines for selecting appropriate sample sizes.</abstract><pub>IEEE</pub><doi>10.1109/ECTC.1995.514399</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9780780327368
ispartof 1995 Proceedings. 45th Electronic Components and Technology Conference, 1995, p.300-304
issn
language eng
recordid cdi_ieee_primary_514399
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Assembly
Ceramics
Compressive stress
Encapsulation
Mechanical variables measurement
Piezoresistance
Semiconductor device measurement
Shearing
Stress measurement
Testing
title Liquid encapsulant stress variations as measured with the ATCO4 assembly test chip
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T05%3A21%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Liquid%20encapsulant%20stress%20variations%20as%20measured%20with%20the%20ATCO4%20assembly%20test%20chip&rft.btitle=1995%20Proceedings.%2045th%20Electronic%20Components%20and%20Technology%20Conference&rft.au=Sweet,%20J.N.&rft.date=1995&rft.spage=300&rft.epage=304&rft.pages=300-304&rft.isbn=9780780327368&rft.isbn_list=0780327365&rft_id=info:doi/10.1109/ECTC.1995.514399&rft_dat=%3Cieee_6IE%3E514399%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-ieee_primary_5143993%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=514399&rfr_iscdi=true