Loading…
Characterization of water vapor permeation through thin film Parylene C
A microfluidic structure to measure water vapor permeation through thin film Parylene C was successfully fabricated and tested. Chips were re-tested multiple times with consistent results. These chips were tested at 20degC, 30%RH and measured WVTR data that matched equivalent wet-cup/beaker tests, s...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A microfluidic structure to measure water vapor permeation through thin film Parylene C was successfully fabricated and tested. Chips were re-tested multiple times with consistent results. These chips were tested at 20degC, 30%RH and measured WVTR data that matched equivalent wet-cup/beaker tests, showing that these devices are indeed functional and can be used to measure WVTR with repeatable reliability. Using the Arrhenius Relation and varied temperature testing, activation energies were determined for water vapor through Parylene C that agree closely with literature and also better predicts Parylene C behavior than the previously reported activation energy. |
---|---|
ISSN: | 2159-547X |
DOI: | 10.1109/SENSOR.2009.5285687 |