Loading…

Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration

There is often a strong correlation between elevated levels of intraocular pressure (IOP) and glaucoma; however, the underlying mechanisms that lead to blindness are not well understood. The key may lie in the study of genetic factors which determine IOP and lead to glaucoma-related blindness. Mice...

Full description

Saved in:
Bibliographic Details
Published in:2010 Annual International Conference of the IEEE Engineering in Medicine and Biology 2010-01, p.6429-6432
Main Authors: Chow, Eric Y, Ha, D, Tse-Yu Lin, deVries, Wilhelmine N, John, Simon W M, Chappell, William J, Irazoqui, Pedro P
Format: Article
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 6432
container_issue
container_start_page 6429
container_title 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
container_volume
creator Chow, Eric Y
Ha, D
Tse-Yu Lin
deVries, Wilhelmine N
John, Simon W M
Chappell, William J
Irazoqui, Pedro P
description There is often a strong correlation between elevated levels of intraocular pressure (IOP) and glaucoma; however, the underlying mechanisms that lead to blindness are not well understood. The key may lie in the study of genetic factors which determine IOP and lead to glaucoma-related blindness. Mice are typically used for genetic research due to their short generation time and accelerated lifespan, manageability, the availability of established and pure lines, and the ability to manipulate the genome. Post genetic manipulation, IOP monitoring at regular intervals is needed and for large scale testing, on the order of thousands of mice, it is crucial to have at least a partially automated data collection scheme. This work presents a fully wireless system on a chip that measures 300 μm in its widest dimension, has a wireless microwave-based data and power link, and is capable of relaying digitized pressure recordings to a nearby base-station.
doi_str_mv 10.1109/IEMBS.2010.5627324
format article
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5627324</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5627324</ieee_id><sourcerecordid>5627324</sourcerecordid><originalsourceid>FETCH-LOGICAL-i370t-1140c0e75b0f14973a9903ea6ea6253817677ef972df49189401afbbc7995fea3</originalsourceid><addsrcrecordid>eNpFkNtKxDAQhuMJ96AvoDd5gWomh6a51GXVhRUvVsG7JW2nS6RNlyS9EHx4Ky4KA8Pw_fNd_IRcAbsBYOZ2tXy-39xwNt4q51pweURmILmUErjkx2QKShWZzEGd_AMhT0fAjMzyQr9PyCzGD8Y4YwrOyYSPJNfApuRrM5RZNZSuop1rW9dhwkCdT8H21dDaQPcBYxwC0q73LvXB-R113b61PtHUU_S2bJHu0GMaJTENtcNIe__3mDlfDxXW1OMQ-hp_osEm1_sLctbYNuLlYc_J28PydfGUrV8eV4u7deaEZikDkKxiqFXJGpBGC2sME2jzcbgSBehca2yM5nUjDRRGMrBNWVbaGNWgFXNy_et1iLjdB9fZ8Lk9tCm-AWxRZng</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Chow, Eric Y ; Ha, D ; Tse-Yu Lin ; deVries, Wilhelmine N ; John, Simon W M ; Chappell, William J ; Irazoqui, Pedro P</creator><creatorcontrib>Chow, Eric Y ; Ha, D ; Tse-Yu Lin ; deVries, Wilhelmine N ; John, Simon W M ; Chappell, William J ; Irazoqui, Pedro P</creatorcontrib><description>There is often a strong correlation between elevated levels of intraocular pressure (IOP) and glaucoma; however, the underlying mechanisms that lead to blindness are not well understood. The key may lie in the study of genetic factors which determine IOP and lead to glaucoma-related blindness. Mice are typically used for genetic research due to their short generation time and accelerated lifespan, manageability, the availability of established and pure lines, and the ability to manipulate the genome. Post genetic manipulation, IOP monitoring at regular intervals is needed and for large scale testing, on the order of thousands of mice, it is crucial to have at least a partially automated data collection scheme. This work presents a fully wireless system on a chip that measures 300 μm in its widest dimension, has a wireless microwave-based data and power link, and is capable of relaying digitized pressure recordings to a nearby base-station.</description><identifier>ISSN: 1094-687X</identifier><identifier>ISBN: 1424441234</identifier><identifier>ISBN: 9781424441235</identifier><identifier>EISSN: 1558-4615</identifier><identifier>EISBN: 1424441242</identifier><identifier>EISBN: 9781424441242</identifier><identifier>DOI: 10.1109/IEMBS.2010.5627324</identifier><identifier>PMID: 21096710</identifier><language>eng</language><publisher>IEEE</publisher><subject>Capacitors ; Genetics ; Mice ; Micromechanical devices ; Transmitters ; Wireless communication ; Wireless sensor networks</subject><ispartof>2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010-01, p.6429-6432</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5627324$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5627324$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Chow, Eric Y</creatorcontrib><creatorcontrib>Ha, D</creatorcontrib><creatorcontrib>Tse-Yu Lin</creatorcontrib><creatorcontrib>deVries, Wilhelmine N</creatorcontrib><creatorcontrib>John, Simon W M</creatorcontrib><creatorcontrib>Chappell, William J</creatorcontrib><creatorcontrib>Irazoqui, Pedro P</creatorcontrib><title>Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration</title><title>2010 Annual International Conference of the IEEE Engineering in Medicine and Biology</title><addtitle>IEMBS</addtitle><description>There is often a strong correlation between elevated levels of intraocular pressure (IOP) and glaucoma; however, the underlying mechanisms that lead to blindness are not well understood. The key may lie in the study of genetic factors which determine IOP and lead to glaucoma-related blindness. Mice are typically used for genetic research due to their short generation time and accelerated lifespan, manageability, the availability of established and pure lines, and the ability to manipulate the genome. Post genetic manipulation, IOP monitoring at regular intervals is needed and for large scale testing, on the order of thousands of mice, it is crucial to have at least a partially automated data collection scheme. This work presents a fully wireless system on a chip that measures 300 μm in its widest dimension, has a wireless microwave-based data and power link, and is capable of relaying digitized pressure recordings to a nearby base-station.</description><subject>Capacitors</subject><subject>Genetics</subject><subject>Mice</subject><subject>Micromechanical devices</subject><subject>Transmitters</subject><subject>Wireless communication</subject><subject>Wireless sensor networks</subject><issn>1094-687X</issn><issn>1558-4615</issn><isbn>1424441234</isbn><isbn>9781424441235</isbn><isbn>1424441242</isbn><isbn>9781424441242</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>6IE</sourceid><recordid>eNpFkNtKxDAQhuMJ96AvoDd5gWomh6a51GXVhRUvVsG7JW2nS6RNlyS9EHx4Ky4KA8Pw_fNd_IRcAbsBYOZ2tXy-39xwNt4q51pweURmILmUErjkx2QKShWZzEGd_AMhT0fAjMzyQr9PyCzGD8Y4YwrOyYSPJNfApuRrM5RZNZSuop1rW9dhwkCdT8H21dDaQPcBYxwC0q73LvXB-R113b61PtHUU_S2bJHu0GMaJTENtcNIe__3mDlfDxXW1OMQ-hp_osEm1_sLctbYNuLlYc_J28PydfGUrV8eV4u7deaEZikDkKxiqFXJGpBGC2sME2jzcbgSBehca2yM5nUjDRRGMrBNWVbaGNWgFXNy_et1iLjdB9fZ8Lk9tCm-AWxRZng</recordid><startdate>20100101</startdate><enddate>20100101</enddate><creator>Chow, Eric Y</creator><creator>Ha, D</creator><creator>Tse-Yu Lin</creator><creator>deVries, Wilhelmine N</creator><creator>John, Simon W M</creator><creator>Chappell, William J</creator><creator>Irazoqui, Pedro P</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20100101</creationdate><title>Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration</title><author>Chow, Eric Y ; Ha, D ; Tse-Yu Lin ; deVries, Wilhelmine N ; John, Simon W M ; Chappell, William J ; Irazoqui, Pedro P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i370t-1140c0e75b0f14973a9903ea6ea6253817677ef972df49189401afbbc7995fea3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Capacitors</topic><topic>Genetics</topic><topic>Mice</topic><topic>Micromechanical devices</topic><topic>Transmitters</topic><topic>Wireless communication</topic><topic>Wireless sensor networks</topic><toplevel>online_resources</toplevel><creatorcontrib>Chow, Eric Y</creatorcontrib><creatorcontrib>Ha, D</creatorcontrib><creatorcontrib>Tse-Yu Lin</creatorcontrib><creatorcontrib>deVries, Wilhelmine N</creatorcontrib><creatorcontrib>John, Simon W M</creatorcontrib><creatorcontrib>Chappell, William J</creatorcontrib><creatorcontrib>Irazoqui, Pedro P</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><jtitle>2010 Annual International Conference of the IEEE Engineering in Medicine and Biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Chow, Eric Y</au><au>Ha, D</au><au>Tse-Yu Lin</au><au>deVries, Wilhelmine N</au><au>John, Simon W M</au><au>Chappell, William J</au><au>Irazoqui, Pedro P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration</atitle><jtitle>2010 Annual International Conference of the IEEE Engineering in Medicine and Biology</jtitle><stitle>IEMBS</stitle><date>2010-01-01</date><risdate>2010</risdate><spage>6429</spage><epage>6432</epage><pages>6429-6432</pages><issn>1094-687X</issn><eissn>1558-4615</eissn><isbn>1424441234</isbn><isbn>9781424441235</isbn><eisbn>1424441242</eisbn><eisbn>9781424441242</eisbn><abstract>There is often a strong correlation between elevated levels of intraocular pressure (IOP) and glaucoma; however, the underlying mechanisms that lead to blindness are not well understood. The key may lie in the study of genetic factors which determine IOP and lead to glaucoma-related blindness. Mice are typically used for genetic research due to their short generation time and accelerated lifespan, manageability, the availability of established and pure lines, and the ability to manipulate the genome. Post genetic manipulation, IOP monitoring at regular intervals is needed and for large scale testing, on the order of thousands of mice, it is crucial to have at least a partially automated data collection scheme. This work presents a fully wireless system on a chip that measures 300 μm in its widest dimension, has a wireless microwave-based data and power link, and is capable of relaying digitized pressure recordings to a nearby base-station.</abstract><pub>IEEE</pub><pmid>21096710</pmid><doi>10.1109/IEMBS.2010.5627324</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1094-687X
ispartof 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010-01, p.6429-6432
issn 1094-687X
1558-4615
language eng
recordid cdi_ieee_primary_5627324
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Capacitors
Genetics
Mice
Micromechanical devices
Transmitters
Wireless communication
Wireless sensor networks
title Sub-cubic millimeter intraocular pressure monitoring implant to enable genetic studies on pressure-induced neurodegeneration
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T21%3A52%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sub-cubic%20millimeter%20intraocular%20pressure%20monitoring%20implant%20to%20enable%20genetic%20studies%20on%20pressure-induced%20neurodegeneration&rft.jtitle=2010%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology&rft.au=Chow,%20Eric%20Y&rft.date=2010-01-01&rft.spage=6429&rft.epage=6432&rft.pages=6429-6432&rft.issn=1094-687X&rft.eissn=1558-4615&rft.isbn=1424441234&rft.isbn_list=9781424441235&rft_id=info:doi/10.1109/IEMBS.2010.5627324&rft.eisbn=1424441242&rft.eisbn_list=9781424441242&rft_dat=%3Cieee_6IE%3E5627324%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i370t-1140c0e75b0f14973a9903ea6ea6253817677ef972df49189401afbbc7995fea3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/21096710&rft_ieee_id=5627324&rfr_iscdi=true