Loading…
Automatic Identification of Float Flowmeter's Float
According to the automatic verification of float flowmeter problems, we put forward a device, and it can acquire float height. An MVC - II - 1MM camera is used to capture flowmeter images, and saves them in computer in the form of BMP files. By some functions, such as the edge detection, filtering,...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 4 |
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Xiao-xuan Cao Yu-ming Shen |
description | According to the automatic verification of float flowmeter problems, we put forward a device, and it can acquire float height. An MVC - II - 1MM camera is used to capture flowmeter images, and saves them in computer in the form of BMP files. By some functions, such as the edge detection, filtering, binary, expansion, refined, etc, and other algorithms programmed by specific characteristics the float position is detected. This measurement has a precision of 10% smallest calibration. |
doi_str_mv | 10.1109/ICEEE.2010.5660477 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5660477</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5660477</ieee_id><sourcerecordid>5660477</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-e47bfc31607200846bb6ebf74020677159369cb8730301dc72a82da4dc8db77a3</originalsourceid><addsrcrecordid>eNotj0tLw0AUhUekoLb5A7rJzlXqnUfmzixLSDVQcNN9mSeMNI0kI-K_N6U5i3P4zuJyDyHPFLaUgn7rmrZttwxmrqUEgXhHnqhgQiCVlN-TQqNauNb0gRTT9AWzaoZc6EfCdz956E1Orux8uOQUk5tpuJRDLPfnweSr__Yhh_F1ujUbsormPIViyTU57ttj81EdPt-7ZneokoZcBYE2Ok4lIANQQlorg40ogIHE6ztcamcVcuBAvUNmFPNGeKe8RTR8TV5uZ1MI4fQ9pt6Mf6dlJv8HAN5EoQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Automatic Identification of Float Flowmeter's Float</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Xiao-xuan Cao ; Yu-ming Shen</creator><creatorcontrib>Xiao-xuan Cao ; Yu-ming Shen</creatorcontrib><description>According to the automatic verification of float flowmeter problems, we put forward a device, and it can acquire float height. An MVC - II - 1MM camera is used to capture flowmeter images, and saves them in computer in the form of BMP files. By some functions, such as the edge detection, filtering, binary, expansion, refined, etc, and other algorithms programmed by specific characteristics the float position is detected. This measurement has a precision of 10% smallest calibration.</description><identifier>ISBN: 9781424471591</identifier><identifier>ISBN: 1424471591</identifier><identifier>EISBN: 1424471613</identifier><identifier>EISBN: 9781424471607</identifier><identifier>EISBN: 1424471605</identifier><identifier>EISBN: 9781424471614</identifier><identifier>DOI: 10.1109/ICEEE.2010.5660477</identifier><language>eng</language><publisher>IEEE</publisher><subject>Calibration ; Electron tubes ; Glass ; Image edge detection ; Pixel ; Rotors</subject><ispartof>2010 International Conference on E-Product E-Service and E-Entertainment, 2010, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5660477$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5660477$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Xiao-xuan Cao</creatorcontrib><creatorcontrib>Yu-ming Shen</creatorcontrib><title>Automatic Identification of Float Flowmeter's Float</title><title>2010 International Conference on E-Product E-Service and E-Entertainment</title><addtitle>ICEEENT</addtitle><description>According to the automatic verification of float flowmeter problems, we put forward a device, and it can acquire float height. An MVC - II - 1MM camera is used to capture flowmeter images, and saves them in computer in the form of BMP files. By some functions, such as the edge detection, filtering, binary, expansion, refined, etc, and other algorithms programmed by specific characteristics the float position is detected. This measurement has a precision of 10% smallest calibration.</description><subject>Calibration</subject><subject>Electron tubes</subject><subject>Glass</subject><subject>Image edge detection</subject><subject>Pixel</subject><subject>Rotors</subject><isbn>9781424471591</isbn><isbn>1424471591</isbn><isbn>1424471613</isbn><isbn>9781424471607</isbn><isbn>1424471605</isbn><isbn>9781424471614</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotj0tLw0AUhUekoLb5A7rJzlXqnUfmzixLSDVQcNN9mSeMNI0kI-K_N6U5i3P4zuJyDyHPFLaUgn7rmrZttwxmrqUEgXhHnqhgQiCVlN-TQqNauNb0gRTT9AWzaoZc6EfCdz956E1Orux8uOQUk5tpuJRDLPfnweSr__Yhh_F1ujUbsormPIViyTU57ttj81EdPt-7ZneokoZcBYE2Ok4lIANQQlorg40ogIHE6ztcamcVcuBAvUNmFPNGeKe8RTR8TV5uZ1MI4fQ9pt6Mf6dlJv8HAN5EoQ</recordid><startdate>201011</startdate><enddate>201011</enddate><creator>Xiao-xuan Cao</creator><creator>Yu-ming Shen</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201011</creationdate><title>Automatic Identification of Float Flowmeter's Float</title><author>Xiao-xuan Cao ; Yu-ming Shen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-e47bfc31607200846bb6ebf74020677159369cb8730301dc72a82da4dc8db77a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Calibration</topic><topic>Electron tubes</topic><topic>Glass</topic><topic>Image edge detection</topic><topic>Pixel</topic><topic>Rotors</topic><toplevel>online_resources</toplevel><creatorcontrib>Xiao-xuan Cao</creatorcontrib><creatorcontrib>Yu-ming Shen</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Xiao-xuan Cao</au><au>Yu-ming Shen</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Automatic Identification of Float Flowmeter's Float</atitle><btitle>2010 International Conference on E-Product E-Service and E-Entertainment</btitle><stitle>ICEEENT</stitle><date>2010-11</date><risdate>2010</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><isbn>9781424471591</isbn><isbn>1424471591</isbn><eisbn>1424471613</eisbn><eisbn>9781424471607</eisbn><eisbn>1424471605</eisbn><eisbn>9781424471614</eisbn><abstract>According to the automatic verification of float flowmeter problems, we put forward a device, and it can acquire float height. An MVC - II - 1MM camera is used to capture flowmeter images, and saves them in computer in the form of BMP files. By some functions, such as the edge detection, filtering, binary, expansion, refined, etc, and other algorithms programmed by specific characteristics the float position is detected. This measurement has a precision of 10% smallest calibration.</abstract><pub>IEEE</pub><doi>10.1109/ICEEE.2010.5660477</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781424471591 |
ispartof | 2010 International Conference on E-Product E-Service and E-Entertainment, 2010, p.1-4 |
issn | |
language | eng |
recordid | cdi_ieee_primary_5660477 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Calibration Electron tubes Glass Image edge detection Pixel Rotors |
title | Automatic Identification of Float Flowmeter's Float |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A31%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Automatic%20Identification%20of%20Float%20Flowmeter's%20Float&rft.btitle=2010%20International%20Conference%20on%20E-Product%20E-Service%20and%20E-Entertainment&rft.au=Xiao-xuan%20Cao&rft.date=2010-11&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.isbn=9781424471591&rft.isbn_list=1424471591&rft_id=info:doi/10.1109/ICEEE.2010.5660477&rft.eisbn=1424471613&rft.eisbn_list=9781424471607&rft.eisbn_list=1424471605&rft.eisbn_list=9781424471614&rft_dat=%3Cieee_6IE%3E5660477%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i90t-e47bfc31607200846bb6ebf74020677159369cb8730301dc72a82da4dc8db77a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5660477&rfr_iscdi=true |