Loading…

Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to -Link Chain

A new method for the estimation of multi-link angular kinematics in the sagittal plane, using one single-axis accelerometer (SAA) per segment, is presented in this paper. A preliminary calibration, using SAAs and a reference system (encoder or stereo-photogrammetry), allows the estimation of sensors...

Full description

Saved in:
Bibliographic Details
Published in:IEEE sensors journal 2012-03, Vol.12 (3), p.479-486
Main Authors: Bagala, F., Fuschillo, V. L., Chiari, L., Cappello, A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743
cites cdi_FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743
container_end_page 486
container_issue 3
container_start_page 479
container_title IEEE sensors journal
container_volume 12
creator Bagala, F.
Fuschillo, V. L.
Chiari, L.
Cappello, A.
description A new method for the estimation of multi-link angular kinematics in the sagittal plane, using one single-axis accelerometer (SAA) per segment, is presented in this paper. A preliminary calibration, using SAAs and a reference system (encoder or stereo-photogrammetry), allows the estimation of sensors position and orientation and segment lengths. These parameters are then used to predict the chain kinematics using the SAAs only. To evaluate the method, the algorithm is first tested on a mechanical arm equipped with a reference encoder. A general method for estimating the kinematics of an N-link chain is also provided. Finally, a three-link biomechanical model is applied to a human subject to estimate the joint angles during squat tasks; a stereo-photogrammetric system is used for validation. The results are very close to the reference values. Mean descriptive (predictive) root mean squared error (RMSE) is 0.15 ° (0.16 ° ) for the inverted pendulum, and 0.39 ° (0.59 ° ) for the shank, 0.82 ° (1.06 ° ) for the thigh, 0.87 ° (1.09 ° ) for the HAT (head-arm-trunk) in the three-link model. The mean value of RMSE without calibration is 1.02 ° for the inverted pendulum, and 11.01 ° (shank), 11.39 ° (thigh) and 12.21 ° (HAT) in the three-link model. These results suggest that, after the calibration procedure, one SAA per segment is enough to estimate 2D joint angles accurately in a kinematic chain of any number of links.
doi_str_mv 10.1109/JSEN.2011.2107897
format article
fullrecord <record><control><sourceid>crossref_ieee_</sourceid><recordid>TN_cdi_ieee_primary_5699901</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5699901</ieee_id><sourcerecordid>10_1109_JSEN_2011_2107897</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743</originalsourceid><addsrcrecordid>eNo9kM9Kw0AYxIMoWKsPIF72BVL3y2azWW8htlotKlTBW9g_X-pqkspuKvbtbWjxNHOYGZhfFF0CnQBQef2wnD5NEgowSYCKXIqjaASc5zGIND8ePKNxysT7aXQWwielIAUXowhL1TjtVY-WJLek6FabRnny6DpsVe9MIHpLlq5bNRgXvy6Qwhhs0K9b7NGHGzLbWTLvftAPEy_Y2U2zaUm_JvHCdV-k_FCuO49OatUEvDjoOHqbTV_L-3jxfDcvi0VsQGR5nHLDLGQGIbOQKC04ZsZKbhONTII1QjBuM2q5yHcXWZ1roTVHXSc8z0TKxhHsd41fh-Cxrr69a5XfVkCrgVM1cKoGTtWB065zte84RPzP80xKSYH9AX-OZEM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to -Link Chain</title><source>IEEE Xplore (Online service)</source><creator>Bagala, F. ; Fuschillo, V. L. ; Chiari, L. ; Cappello, A.</creator><creatorcontrib>Bagala, F. ; Fuschillo, V. L. ; Chiari, L. ; Cappello, A.</creatorcontrib><description>A new method for the estimation of multi-link angular kinematics in the sagittal plane, using one single-axis accelerometer (SAA) per segment, is presented in this paper. A preliminary calibration, using SAAs and a reference system (encoder or stereo-photogrammetry), allows the estimation of sensors position and orientation and segment lengths. These parameters are then used to predict the chain kinematics using the SAAs only. To evaluate the method, the algorithm is first tested on a mechanical arm equipped with a reference encoder. A general method for estimating the kinematics of an N-link chain is also provided. Finally, a three-link biomechanical model is applied to a human subject to estimate the joint angles during squat tasks; a stereo-photogrammetric system is used for validation. The results are very close to the reference values. Mean descriptive (predictive) root mean squared error (RMSE) is 0.15 ° (0.16 ° ) for the inverted pendulum, and 0.39 ° (0.59 ° ) for the shank, 0.82 ° (1.06 ° ) for the thigh, 0.87 ° (1.09 ° ) for the HAT (head-arm-trunk) in the three-link model. The mean value of RMSE without calibration is 1.02 ° for the inverted pendulum, and 11.01 ° (shank), 11.39 ° (thigh) and 12.21 ° (HAT) in the three-link model. These results suggest that, after the calibration procedure, one SAA per segment is enough to estimate 2D joint angles accurately in a kinematic chain of any number of links.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2011.2107897</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>IEEE</publisher><subject>Accelerometers ; Biological system modeling ; Calibration ; joint angle ; Joints ; Kinematics ; Mathematical model ; movement analysis ; multi-link ; single-axis accelerometer ; Thigh</subject><ispartof>IEEE sensors journal, 2012-03, Vol.12 (3), p.479-486</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743</citedby><cites>FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5699901$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Bagala, F.</creatorcontrib><creatorcontrib>Fuschillo, V. L.</creatorcontrib><creatorcontrib>Chiari, L.</creatorcontrib><creatorcontrib>Cappello, A.</creatorcontrib><title>Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to -Link Chain</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>A new method for the estimation of multi-link angular kinematics in the sagittal plane, using one single-axis accelerometer (SAA) per segment, is presented in this paper. A preliminary calibration, using SAAs and a reference system (encoder or stereo-photogrammetry), allows the estimation of sensors position and orientation and segment lengths. These parameters are then used to predict the chain kinematics using the SAAs only. To evaluate the method, the algorithm is first tested on a mechanical arm equipped with a reference encoder. A general method for estimating the kinematics of an N-link chain is also provided. Finally, a three-link biomechanical model is applied to a human subject to estimate the joint angles during squat tasks; a stereo-photogrammetric system is used for validation. The results are very close to the reference values. Mean descriptive (predictive) root mean squared error (RMSE) is 0.15 ° (0.16 ° ) for the inverted pendulum, and 0.39 ° (0.59 ° ) for the shank, 0.82 ° (1.06 ° ) for the thigh, 0.87 ° (1.09 ° ) for the HAT (head-arm-trunk) in the three-link model. The mean value of RMSE without calibration is 1.02 ° for the inverted pendulum, and 11.01 ° (shank), 11.39 ° (thigh) and 12.21 ° (HAT) in the three-link model. These results suggest that, after the calibration procedure, one SAA per segment is enough to estimate 2D joint angles accurately in a kinematic chain of any number of links.</description><subject>Accelerometers</subject><subject>Biological system modeling</subject><subject>Calibration</subject><subject>joint angle</subject><subject>Joints</subject><subject>Kinematics</subject><subject>Mathematical model</subject><subject>movement analysis</subject><subject>multi-link</subject><subject>single-axis accelerometer</subject><subject>Thigh</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNo9kM9Kw0AYxIMoWKsPIF72BVL3y2azWW8htlotKlTBW9g_X-pqkspuKvbtbWjxNHOYGZhfFF0CnQBQef2wnD5NEgowSYCKXIqjaASc5zGIND8ePKNxysT7aXQWwielIAUXowhL1TjtVY-WJLek6FabRnny6DpsVe9MIHpLlq5bNRgXvy6Qwhhs0K9b7NGHGzLbWTLvftAPEy_Y2U2zaUm_JvHCdV-k_FCuO49OatUEvDjoOHqbTV_L-3jxfDcvi0VsQGR5nHLDLGQGIbOQKC04ZsZKbhONTII1QjBuM2q5yHcXWZ1roTVHXSc8z0TKxhHsd41fh-Cxrr69a5XfVkCrgVM1cKoGTtWB065zte84RPzP80xKSYH9AX-OZEM</recordid><startdate>201203</startdate><enddate>201203</enddate><creator>Bagala, F.</creator><creator>Fuschillo, V. L.</creator><creator>Chiari, L.</creator><creator>Cappello, A.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201203</creationdate><title>Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to -Link Chain</title><author>Bagala, F. ; Fuschillo, V. L. ; Chiari, L. ; Cappello, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Accelerometers</topic><topic>Biological system modeling</topic><topic>Calibration</topic><topic>joint angle</topic><topic>Joints</topic><topic>Kinematics</topic><topic>Mathematical model</topic><topic>movement analysis</topic><topic>multi-link</topic><topic>single-axis accelerometer</topic><topic>Thigh</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bagala, F.</creatorcontrib><creatorcontrib>Fuschillo, V. L.</creatorcontrib><creatorcontrib>Chiari, L.</creatorcontrib><creatorcontrib>Cappello, A.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) Online</collection><collection>IEEE Electronic Library Online</collection><collection>CrossRef</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bagala, F.</au><au>Fuschillo, V. L.</au><au>Chiari, L.</au><au>Cappello, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to -Link Chain</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2012-03</date><risdate>2012</risdate><volume>12</volume><issue>3</issue><spage>479</spage><epage>486</epage><pages>479-486</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>A new method for the estimation of multi-link angular kinematics in the sagittal plane, using one single-axis accelerometer (SAA) per segment, is presented in this paper. A preliminary calibration, using SAAs and a reference system (encoder or stereo-photogrammetry), allows the estimation of sensors position and orientation and segment lengths. These parameters are then used to predict the chain kinematics using the SAAs only. To evaluate the method, the algorithm is first tested on a mechanical arm equipped with a reference encoder. A general method for estimating the kinematics of an N-link chain is also provided. Finally, a three-link biomechanical model is applied to a human subject to estimate the joint angles during squat tasks; a stereo-photogrammetric system is used for validation. The results are very close to the reference values. Mean descriptive (predictive) root mean squared error (RMSE) is 0.15 ° (0.16 ° ) for the inverted pendulum, and 0.39 ° (0.59 ° ) for the shank, 0.82 ° (1.06 ° ) for the thigh, 0.87 ° (1.09 ° ) for the HAT (head-arm-trunk) in the three-link model. The mean value of RMSE without calibration is 1.02 ° for the inverted pendulum, and 11.01 ° (shank), 11.39 ° (thigh) and 12.21 ° (HAT) in the three-link model. These results suggest that, after the calibration procedure, one SAA per segment is enough to estimate 2D joint angles accurately in a kinematic chain of any number of links.</abstract><pub>IEEE</pub><doi>10.1109/JSEN.2011.2107897</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1530-437X
ispartof IEEE sensors journal, 2012-03, Vol.12 (3), p.479-486
issn 1530-437X
1558-1748
language eng
recordid cdi_ieee_primary_5699901
source IEEE Xplore (Online service)
subjects Accelerometers
Biological system modeling
Calibration
joint angle
Joints
Kinematics
Mathematical model
movement analysis
multi-link
single-axis accelerometer
Thigh
title Calibrated 2D Angular Kinematics by Single-Axis Accelerometers: From Inverted Pendulum to -Link Chain
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T07%3A55%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibrated%202D%20Angular%20Kinematics%20by%20Single-Axis%20Accelerometers:%20From%20Inverted%20Pendulum%20to%20-Link%20Chain&rft.jtitle=IEEE%20sensors%20journal&rft.au=Bagala,%20F.&rft.date=2012-03&rft.volume=12&rft.issue=3&rft.spage=479&rft.epage=486&rft.pages=479-486&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2011.2107897&rft_dat=%3Ccrossref_ieee_%3E10_1109_JSEN_2011_2107897%3C/crossref_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1768-45c3d16ce16d12ab75e6cd95d2be391dc7735d60d5788973f8b7bb5ebf2586743%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5699901&rfr_iscdi=true