Experimental Investigation of the Loop Seal Operation Status and its Judgment in Circulating Fluidized Bed
In this paper, it is shown that the loop seal operation status in circulating fluidized beds, exhibits three different types of flow characteristics, dependent on the solids' fluidized state in the recycle chamber and standpipe. These types of flow characteristics are defined as: (a) Non-operat...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this paper, it is shown that the loop seal operation status in circulating fluidized beds, exhibits three different types of flow characteristics, dependent on the solids' fluidized state in the recycle chamber and standpipe. These types of flow characteristics are defined as: (a) Non-operation, (b) Operation with the solids height in the standpipe, (c) Operation without the solids height in the standpipe. The key pressures in loop seal can indicate these different operation statuses. |
---|---|