Loading…

Identification of cardiovascular baroreflex for probing homeostatic stability

This paper presents a method to identify the cardiovascular baroreflex parameters that are useful for probing homeostatic stability. The work is built upon a physiology-based model of the closed-loop cardiovascular and baroreflex feedback system describing the regulation of heart rate and blood pres...

Full description

Saved in:
Bibliographic Details
Main Authors: Ataee, P, Hahn, J O, Brouse, C, Dumont, G A, Boyce, W T
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 144
container_issue
container_start_page 141
container_title
container_volume
creator Ataee, P
Hahn, J O
Brouse, C
Dumont, G A
Boyce, W T
description This paper presents a method to identify the cardiovascular baroreflex parameters that are useful for probing homeostatic stability. The work is built upon a physiology-based model of the closed-loop cardiovascular and baroreflex feedback system describing the regulation of heart rate and blood pressure. Parametric sensitivity analysis is conducted on the model to classify the model parameters into high-sensitivity, low-sensitivity, and invariant groups based on their relative impacts on the system outputs. The baroreflex identification is formulated as a nonlinear optimization problem in which only high-sensitivity model parameters are identified whereas low-sensitivity and invariant parameters are fixed at their typical values. The advantage of the method is its computational efficiency without significant compromise in performance and accuracy. The method was applied to the experimental data of 10 individuals in the MIMIC Database in the PhysioBank. The promising results suggest potential of the proposed method in probing homeostasis based on the estimates of sympathetic and parasympathetic tones.
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5737929</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5737929</ieee_id><sourcerecordid>5737929</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-a28c30daee7783019d62b1f05b777c638961f8416c9e8a79ef42a0655a8abc053</originalsourceid><addsrcrecordid>eNo1jstKAzEYRuMNnNY-gZu8wEDuf7KU4qVQcaPr8ieTaGQ6KZlR7Ns7YF2dxcf5OGdkwZVQCiR3-pw0QgrdWqvlBVk5sP-bFZekYQJMazSoa7IYx0_GuHOgG_K86eIw5ZQDTrkMtCQasHa5fOMYvnqs1GMtNaY-_tBUKj3U4vPwTj_KPpZxmq1AZ_jc5-l4Q64S9mNcnbgkbw_3r-undvvyuFnfbdvMQU8tChsk6zBGACvnlM4IzxPTHgCCkdYZnqziJrhoEVxMSiAzWqNFH5iWS3L795tjjLtDzXusx50GCU44-QupDU3i</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Identification of cardiovascular baroreflex for probing homeostatic stability</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ataee, P ; Hahn, J O ; Brouse, C ; Dumont, G A ; Boyce, W T</creator><creatorcontrib>Ataee, P ; Hahn, J O ; Brouse, C ; Dumont, G A ; Boyce, W T</creatorcontrib><description>This paper presents a method to identify the cardiovascular baroreflex parameters that are useful for probing homeostatic stability. The work is built upon a physiology-based model of the closed-loop cardiovascular and baroreflex feedback system describing the regulation of heart rate and blood pressure. Parametric sensitivity analysis is conducted on the model to classify the model parameters into high-sensitivity, low-sensitivity, and invariant groups based on their relative impacts on the system outputs. The baroreflex identification is formulated as a nonlinear optimization problem in which only high-sensitivity model parameters are identified whereas low-sensitivity and invariant parameters are fixed at their typical values. The advantage of the method is its computational efficiency without significant compromise in performance and accuracy. The method was applied to the experimental data of 10 individuals in the MIMIC Database in the PhysioBank. The promising results suggest potential of the proposed method in probing homeostasis based on the estimates of sympathetic and parasympathetic tones.</description><identifier>ISSN: 0276-6574</identifier><identifier>ISBN: 9781424473182</identifier><identifier>ISBN: 1424473187</identifier><identifier>EISSN: 2325-8853</identifier><identifier>EISBN: 1424473195</identifier><identifier>EISBN: 9781424473199</identifier><language>eng</language><publisher>IEEE</publisher><subject>Analytical models ; Brain modeling ; Cardiology ; Computational modeling ; Heart rate ; Mathematical model ; Sensitivity</subject><ispartof>2010 Computing in Cardiology, 2010, p.141-144</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5737929$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5737929$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ataee, P</creatorcontrib><creatorcontrib>Hahn, J O</creatorcontrib><creatorcontrib>Brouse, C</creatorcontrib><creatorcontrib>Dumont, G A</creatorcontrib><creatorcontrib>Boyce, W T</creatorcontrib><title>Identification of cardiovascular baroreflex for probing homeostatic stability</title><title>2010 Computing in Cardiology</title><addtitle>CIC</addtitle><description>This paper presents a method to identify the cardiovascular baroreflex parameters that are useful for probing homeostatic stability. The work is built upon a physiology-based model of the closed-loop cardiovascular and baroreflex feedback system describing the regulation of heart rate and blood pressure. Parametric sensitivity analysis is conducted on the model to classify the model parameters into high-sensitivity, low-sensitivity, and invariant groups based on their relative impacts on the system outputs. The baroreflex identification is formulated as a nonlinear optimization problem in which only high-sensitivity model parameters are identified whereas low-sensitivity and invariant parameters are fixed at their typical values. The advantage of the method is its computational efficiency without significant compromise in performance and accuracy. The method was applied to the experimental data of 10 individuals in the MIMIC Database in the PhysioBank. The promising results suggest potential of the proposed method in probing homeostasis based on the estimates of sympathetic and parasympathetic tones.</description><subject>Analytical models</subject><subject>Brain modeling</subject><subject>Cardiology</subject><subject>Computational modeling</subject><subject>Heart rate</subject><subject>Mathematical model</subject><subject>Sensitivity</subject><issn>0276-6574</issn><issn>2325-8853</issn><isbn>9781424473182</isbn><isbn>1424473187</isbn><isbn>1424473195</isbn><isbn>9781424473199</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1jstKAzEYRuMNnNY-gZu8wEDuf7KU4qVQcaPr8ieTaGQ6KZlR7Ns7YF2dxcf5OGdkwZVQCiR3-pw0QgrdWqvlBVk5sP-bFZekYQJMazSoa7IYx0_GuHOgG_K86eIw5ZQDTrkMtCQasHa5fOMYvnqs1GMtNaY-_tBUKj3U4vPwTj_KPpZxmq1AZ_jc5-l4Q64S9mNcnbgkbw_3r-undvvyuFnfbdvMQU8tChsk6zBGACvnlM4IzxPTHgCCkdYZnqziJrhoEVxMSiAzWqNFH5iWS3L795tjjLtDzXusx50GCU44-QupDU3i</recordid><startdate>201009</startdate><enddate>201009</enddate><creator>Ataee, P</creator><creator>Hahn, J O</creator><creator>Brouse, C</creator><creator>Dumont, G A</creator><creator>Boyce, W T</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201009</creationdate><title>Identification of cardiovascular baroreflex for probing homeostatic stability</title><author>Ataee, P ; Hahn, J O ; Brouse, C ; Dumont, G A ; Boyce, W T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-a28c30daee7783019d62b1f05b777c638961f8416c9e8a79ef42a0655a8abc053</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Analytical models</topic><topic>Brain modeling</topic><topic>Cardiology</topic><topic>Computational modeling</topic><topic>Heart rate</topic><topic>Mathematical model</topic><topic>Sensitivity</topic><toplevel>online_resources</toplevel><creatorcontrib>Ataee, P</creatorcontrib><creatorcontrib>Hahn, J O</creatorcontrib><creatorcontrib>Brouse, C</creatorcontrib><creatorcontrib>Dumont, G A</creatorcontrib><creatorcontrib>Boyce, W T</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ataee, P</au><au>Hahn, J O</au><au>Brouse, C</au><au>Dumont, G A</au><au>Boyce, W T</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Identification of cardiovascular baroreflex for probing homeostatic stability</atitle><btitle>2010 Computing in Cardiology</btitle><stitle>CIC</stitle><date>2010-09</date><risdate>2010</risdate><spage>141</spage><epage>144</epage><pages>141-144</pages><issn>0276-6574</issn><eissn>2325-8853</eissn><isbn>9781424473182</isbn><isbn>1424473187</isbn><eisbn>1424473195</eisbn><eisbn>9781424473199</eisbn><abstract>This paper presents a method to identify the cardiovascular baroreflex parameters that are useful for probing homeostatic stability. The work is built upon a physiology-based model of the closed-loop cardiovascular and baroreflex feedback system describing the regulation of heart rate and blood pressure. Parametric sensitivity analysis is conducted on the model to classify the model parameters into high-sensitivity, low-sensitivity, and invariant groups based on their relative impacts on the system outputs. The baroreflex identification is formulated as a nonlinear optimization problem in which only high-sensitivity model parameters are identified whereas low-sensitivity and invariant parameters are fixed at their typical values. The advantage of the method is its computational efficiency without significant compromise in performance and accuracy. The method was applied to the experimental data of 10 individuals in the MIMIC Database in the PhysioBank. The promising results suggest potential of the proposed method in probing homeostasis based on the estimates of sympathetic and parasympathetic tones.</abstract><pub>IEEE</pub><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0276-6574
ispartof 2010 Computing in Cardiology, 2010, p.141-144
issn 0276-6574
2325-8853
language eng
recordid cdi_ieee_primary_5737929
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Analytical models
Brain modeling
Cardiology
Computational modeling
Heart rate
Mathematical model
Sensitivity
title Identification of cardiovascular baroreflex for probing homeostatic stability
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T16%3A03%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Identification%20of%20cardiovascular%20baroreflex%20for%20probing%20homeostatic%20stability&rft.btitle=2010%20Computing%20in%20Cardiology&rft.au=Ataee,%20P&rft.date=2010-09&rft.spage=141&rft.epage=144&rft.pages=141-144&rft.issn=0276-6574&rft.eissn=2325-8853&rft.isbn=9781424473182&rft.isbn_list=1424473187&rft_id=info:doi/&rft.eisbn=1424473195&rft.eisbn_list=9781424473199&rft_dat=%3Cieee_6IE%3E5737929%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-a28c30daee7783019d62b1f05b777c638961f8416c9e8a79ef42a0655a8abc053%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5737929&rfr_iscdi=true