Loading…

On the Development of a Sensor Module for Real-Time Pollution Monitoring

In a Wireless Sensor Network (WSN) application for ambient pollution monitoring, which involves the deployment of a large number (i.e. ~100) of sensors in India and UK to obtain fine-grain pollution data, the selection of gas sensors and the validity of sensor measurements against ground truth are v...

Full description

Saved in:
Bibliographic Details
Main Authors: Shum, L V, Rajalakshmi, P, Afonja, A, McPhillips, G, Binions, R, Cheng, L, Hailes, S
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 9
container_issue
container_start_page 1
container_title
container_volume
creator Shum, L V
Rajalakshmi, P
Afonja, A
McPhillips, G
Binions, R
Cheng, L
Hailes, S
description In a Wireless Sensor Network (WSN) application for ambient pollution monitoring, which involves the deployment of a large number (i.e. ~100) of sensors in India and UK to obtain fine-grain pollution data, the selection of gas sensors and the validity of sensor measurements against ground truth are vitally important to the success of the system. Electrochemical and solid state gas sensors are low- cost, small sensors that are traditionally used for examining exhaust emissions from vehicles, and hence, they are specifically designed to measure a much higher gas concentration than in our measured environment. In this paper, we evaluate the use of gas sensors in a pollution monitoring project using pervasive sensor technology by literature comparison of the different types of gas sensors available commercially; and a discussion on the calibration process of a set of selected Oxygen (O 2 ), Carbon Dioxide (CO 2 ) and Carbon Monoxide (CO) sensors. The results show that the electrochemical CO sensors exhibit linearity against the range of concentrations that we are interested in (0-20ppm). This paper presents in-depth knowledge on sensor selection and calibration against the ground truth to the research community interested in enabling practical development and deployment of WSN gas pollution monitoring systems.
doi_str_mv 10.1109/ICISA.2011.5772355
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_5772355</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5772355</ieee_id><sourcerecordid>5772355</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-c1d872f9b02331fd618bff766c952b34e4777ab38940084d8860698b8534e80a3</originalsourceid><addsrcrecordid>eNpVkEtLw0AcxFdUsNR8Ab3sF0jc9-NY4qOBSsXmXjbNf3Vlky1JKvjtDdiLc5kZfjCHQeiOkoJSYh-qstqtCkYoLaTWjEt5gTKrDRVMCMsY15f_OiNXaMGoYrklwtygbBy_yCylLJNygdbbHk-fgB_hG2I6dtBPOHns8A76MQ34NbWnCNjP8R1czOvQAX5LMZ6mkPoZ92FKQ-g_btG1d3GE7OxLVD8_1eU632xfqnK1yYMlU36grdHM24YwzqlvFTWN91qpg5Ws4QKE1to13FhBiBGtMYooaxojZ2aI40t0_zcbAGB_HELnhp_9-Qr-C6uMTig</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>On the Development of a Sensor Module for Real-Time Pollution Monitoring</title><source>IEEE Xplore All Conference Series</source><creator>Shum, L V ; Rajalakshmi, P ; Afonja, A ; McPhillips, G ; Binions, R ; Cheng, L ; Hailes, S</creator><creatorcontrib>Shum, L V ; Rajalakshmi, P ; Afonja, A ; McPhillips, G ; Binions, R ; Cheng, L ; Hailes, S</creatorcontrib><description>In a Wireless Sensor Network (WSN) application for ambient pollution monitoring, which involves the deployment of a large number (i.e. ~100) of sensors in India and UK to obtain fine-grain pollution data, the selection of gas sensors and the validity of sensor measurements against ground truth are vitally important to the success of the system. Electrochemical and solid state gas sensors are low- cost, small sensors that are traditionally used for examining exhaust emissions from vehicles, and hence, they are specifically designed to measure a much higher gas concentration than in our measured environment. In this paper, we evaluate the use of gas sensors in a pollution monitoring project using pervasive sensor technology by literature comparison of the different types of gas sensors available commercially; and a discussion on the calibration process of a set of selected Oxygen (O 2 ), Carbon Dioxide (CO 2 ) and Carbon Monoxide (CO) sensors. The results show that the electrochemical CO sensors exhibit linearity against the range of concentrations that we are interested in (0-20ppm). This paper presents in-depth knowledge on sensor selection and calibration against the ground truth to the research community interested in enabling practical development and deployment of WSN gas pollution monitoring systems.</description><identifier>ISSN: 2162-9048</identifier><identifier>ISBN: 9781424492220</identifier><identifier>ISBN: 142449222X</identifier><identifier>EISBN: 9781424492237</identifier><identifier>EISBN: 9781424492244</identifier><identifier>EISBN: 1424492238</identifier><identifier>EISBN: 1424492246</identifier><identifier>DOI: 10.1109/ICISA.2011.5772355</identifier><language>eng</language><publisher>IEEE</publisher><subject>Calibration ; Carbon dioxide ; Gases ; Monitoring ; Pollution ; Pollution measurement ; Wireless sensor networks</subject><ispartof>2011 International Conference on Information Science and Applications, 2011, p.1-9</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5772355$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54555,54920,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5772355$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Shum, L V</creatorcontrib><creatorcontrib>Rajalakshmi, P</creatorcontrib><creatorcontrib>Afonja, A</creatorcontrib><creatorcontrib>McPhillips, G</creatorcontrib><creatorcontrib>Binions, R</creatorcontrib><creatorcontrib>Cheng, L</creatorcontrib><creatorcontrib>Hailes, S</creatorcontrib><title>On the Development of a Sensor Module for Real-Time Pollution Monitoring</title><title>2011 International Conference on Information Science and Applications</title><addtitle>ICISA</addtitle><description>In a Wireless Sensor Network (WSN) application for ambient pollution monitoring, which involves the deployment of a large number (i.e. ~100) of sensors in India and UK to obtain fine-grain pollution data, the selection of gas sensors and the validity of sensor measurements against ground truth are vitally important to the success of the system. Electrochemical and solid state gas sensors are low- cost, small sensors that are traditionally used for examining exhaust emissions from vehicles, and hence, they are specifically designed to measure a much higher gas concentration than in our measured environment. In this paper, we evaluate the use of gas sensors in a pollution monitoring project using pervasive sensor technology by literature comparison of the different types of gas sensors available commercially; and a discussion on the calibration process of a set of selected Oxygen (O 2 ), Carbon Dioxide (CO 2 ) and Carbon Monoxide (CO) sensors. The results show that the electrochemical CO sensors exhibit linearity against the range of concentrations that we are interested in (0-20ppm). This paper presents in-depth knowledge on sensor selection and calibration against the ground truth to the research community interested in enabling practical development and deployment of WSN gas pollution monitoring systems.</description><subject>Calibration</subject><subject>Carbon dioxide</subject><subject>Gases</subject><subject>Monitoring</subject><subject>Pollution</subject><subject>Pollution measurement</subject><subject>Wireless sensor networks</subject><issn>2162-9048</issn><isbn>9781424492220</isbn><isbn>142449222X</isbn><isbn>9781424492237</isbn><isbn>9781424492244</isbn><isbn>1424492238</isbn><isbn>1424492246</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNpVkEtLw0AcxFdUsNR8Ab3sF0jc9-NY4qOBSsXmXjbNf3Vlky1JKvjtDdiLc5kZfjCHQeiOkoJSYh-qstqtCkYoLaTWjEt5gTKrDRVMCMsY15f_OiNXaMGoYrklwtygbBy_yCylLJNygdbbHk-fgB_hG2I6dtBPOHns8A76MQ34NbWnCNjP8R1czOvQAX5LMZ6mkPoZ92FKQ-g_btG1d3GE7OxLVD8_1eU632xfqnK1yYMlU36grdHM24YwzqlvFTWN91qpg5Ws4QKE1to13FhBiBGtMYooaxojZ2aI40t0_zcbAGB_HELnhp_9-Qr-C6uMTig</recordid><startdate>201104</startdate><enddate>201104</enddate><creator>Shum, L V</creator><creator>Rajalakshmi, P</creator><creator>Afonja, A</creator><creator>McPhillips, G</creator><creator>Binions, R</creator><creator>Cheng, L</creator><creator>Hailes, S</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201104</creationdate><title>On the Development of a Sensor Module for Real-Time Pollution Monitoring</title><author>Shum, L V ; Rajalakshmi, P ; Afonja, A ; McPhillips, G ; Binions, R ; Cheng, L ; Hailes, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-c1d872f9b02331fd618bff766c952b34e4777ab38940084d8860698b8534e80a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Calibration</topic><topic>Carbon dioxide</topic><topic>Gases</topic><topic>Monitoring</topic><topic>Pollution</topic><topic>Pollution measurement</topic><topic>Wireless sensor networks</topic><toplevel>online_resources</toplevel><creatorcontrib>Shum, L V</creatorcontrib><creatorcontrib>Rajalakshmi, P</creatorcontrib><creatorcontrib>Afonja, A</creatorcontrib><creatorcontrib>McPhillips, G</creatorcontrib><creatorcontrib>Binions, R</creatorcontrib><creatorcontrib>Cheng, L</creatorcontrib><creatorcontrib>Hailes, S</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Shum, L V</au><au>Rajalakshmi, P</au><au>Afonja, A</au><au>McPhillips, G</au><au>Binions, R</au><au>Cheng, L</au><au>Hailes, S</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>On the Development of a Sensor Module for Real-Time Pollution Monitoring</atitle><btitle>2011 International Conference on Information Science and Applications</btitle><stitle>ICISA</stitle><date>2011-04</date><risdate>2011</risdate><spage>1</spage><epage>9</epage><pages>1-9</pages><issn>2162-9048</issn><isbn>9781424492220</isbn><isbn>142449222X</isbn><eisbn>9781424492237</eisbn><eisbn>9781424492244</eisbn><eisbn>1424492238</eisbn><eisbn>1424492246</eisbn><abstract>In a Wireless Sensor Network (WSN) application for ambient pollution monitoring, which involves the deployment of a large number (i.e. ~100) of sensors in India and UK to obtain fine-grain pollution data, the selection of gas sensors and the validity of sensor measurements against ground truth are vitally important to the success of the system. Electrochemical and solid state gas sensors are low- cost, small sensors that are traditionally used for examining exhaust emissions from vehicles, and hence, they are specifically designed to measure a much higher gas concentration than in our measured environment. In this paper, we evaluate the use of gas sensors in a pollution monitoring project using pervasive sensor technology by literature comparison of the different types of gas sensors available commercially; and a discussion on the calibration process of a set of selected Oxygen (O 2 ), Carbon Dioxide (CO 2 ) and Carbon Monoxide (CO) sensors. The results show that the electrochemical CO sensors exhibit linearity against the range of concentrations that we are interested in (0-20ppm). This paper presents in-depth knowledge on sensor selection and calibration against the ground truth to the research community interested in enabling practical development and deployment of WSN gas pollution monitoring systems.</abstract><pub>IEEE</pub><doi>10.1109/ICISA.2011.5772355</doi><tpages>9</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2162-9048
ispartof 2011 International Conference on Information Science and Applications, 2011, p.1-9
issn 2162-9048
language eng
recordid cdi_ieee_primary_5772355
source IEEE Xplore All Conference Series
subjects Calibration
Carbon dioxide
Gases
Monitoring
Pollution
Pollution measurement
Wireless sensor networks
title On the Development of a Sensor Module for Real-Time Pollution Monitoring
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T07%3A11%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=On%20the%20Development%20of%20a%20Sensor%20Module%20for%20Real-Time%20Pollution%20Monitoring&rft.btitle=2011%20International%20Conference%20on%20Information%20Science%20and%20Applications&rft.au=Shum,%20L%20V&rft.date=2011-04&rft.spage=1&rft.epage=9&rft.pages=1-9&rft.issn=2162-9048&rft.isbn=9781424492220&rft.isbn_list=142449222X&rft_id=info:doi/10.1109/ICISA.2011.5772355&rft.eisbn=9781424492237&rft.eisbn_list=9781424492244&rft.eisbn_list=1424492238&rft.eisbn_list=1424492246&rft_dat=%3Cieee_CHZPO%3E5772355%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i90t-c1d872f9b02331fd618bff766c952b34e4777ab38940084d8860698b8534e80a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5772355&rfr_iscdi=true