Measurement of interface pressure applied by medical compression bandages

Medical compression bandages (MCBs) are widely used to treat venous leg ulcers. Interface pressure measurement devices like PicoPress® transducer are used occasionally to measure the pressure applied by MCBs to train nurses to apply MCBs with the correct pressure profile to patient's leg and fo...

Full description

Saved in:
Bibliographic Details
Main Authors: Al Khaburi, J., Dehghani-Sanij, A. A., Nelson, E. A., Hutchinson, J.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 294
container_issue
container_start_page 289
container_title
container_volume
creator Al Khaburi, J.
Dehghani-Sanij, A. A.
Nelson, E. A.
Hutchinson, J.
description Medical compression bandages (MCBs) are widely used to treat venous leg ulcers. Interface pressure measurement devices like PicoPress® transducer are used occasionally to measure the pressure applied by MCBs to train nurses to apply MCBs with the correct pressure profile to patient's leg and for quality assurance purposes. However, most of these devices provide only single point pressure measurement. Some of them like the Medical Stocking Tester (MST) and the Oxford Pressure Monitoring MK can provide multiple points of pressure measurement simultaneously. However, the current available systems cannot map the pressures applied by MCBs to a leg at 16 or more points simultaneously. Flexible sensors like FlexiForce® seem to provide a good alternative to current pressure measurement system. This paper will report on the work carried out to compare the pressure measured using FlexiForce® force sensors with the pressures measured using PicoPress®, which is a pneumatic transducer, and FS01 force sensor, which is an ultra profile rigid MEMS force sensor. In addition, it will compare the pressures measured using the three sensing transducers with the pressures computed from the amount of extension in the MCB, which is applied to the medium which these sensors are attached to.
doi_str_mv 10.1109/ICMA.2011.5985672
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5985672</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5985672</ieee_id><sourcerecordid>5985672</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-339b26003ea75a0b91438562bf86b7b368df77d6d5936bd67c20e9bd39af496d3</originalsourceid><addsrcrecordid>eNo90MtOwzAQBVDzkiglH4DY-AcS_IqdWVYRj0it2HTBrrLjMTJK0igOi_49BQqzuYsjXekOIXecFZwzeGjqzaoQjPOihKrURpyRG66EUhXnypyTheClyI1SbxckA1P9mRSX_yb5NclS-mDH0xpAiAVpNmjT54Q9DjPdBxqHGadgW6TjhOlbqB3HLqKn7kB79LG1HW33_Q_H_UCdHbx9x3RLroLtEmanXJLt0-O2fsnXr89NvVrnEdicSwlOaMYkWlNa5oAredwjXKi0M07qygdjvPYlSO28Nq1gCM5LsEGB9nJJ7n9rIyLuxin2djrsTk-RX0I4UZM</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Measurement of interface pressure applied by medical compression bandages</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Al Khaburi, J. ; Dehghani-Sanij, A. A. ; Nelson, E. A. ; Hutchinson, J.</creator><creatorcontrib>Al Khaburi, J. ; Dehghani-Sanij, A. A. ; Nelson, E. A. ; Hutchinson, J.</creatorcontrib><description>Medical compression bandages (MCBs) are widely used to treat venous leg ulcers. Interface pressure measurement devices like PicoPress® transducer are used occasionally to measure the pressure applied by MCBs to train nurses to apply MCBs with the correct pressure profile to patient's leg and for quality assurance purposes. However, most of these devices provide only single point pressure measurement. Some of them like the Medical Stocking Tester (MST) and the Oxford Pressure Monitoring MK can provide multiple points of pressure measurement simultaneously. However, the current available systems cannot map the pressures applied by MCBs to a leg at 16 or more points simultaneously. Flexible sensors like FlexiForce® seem to provide a good alternative to current pressure measurement system. This paper will report on the work carried out to compare the pressure measured using FlexiForce® force sensors with the pressures measured using PicoPress®, which is a pneumatic transducer, and FS01 force sensor, which is an ultra profile rigid MEMS force sensor. In addition, it will compare the pressures measured using the three sensing transducers with the pressures computed from the amount of extension in the MCB, which is applied to the medium which these sensors are attached to.</description><identifier>ISSN: 2152-7431</identifier><identifier>ISBN: 9781424481132</identifier><identifier>ISBN: 1424481139</identifier><identifier>EISSN: 2152-744X</identifier><identifier>EISBN: 1424481147</identifier><identifier>EISBN: 9781424481149</identifier><identifier>EISBN: 1424481155</identifier><identifier>EISBN: 9781424481156</identifier><identifier>DOI: 10.1109/ICMA.2011.5985672</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical measurements ; Compression ; FlexiForce ; Force Sensor ; Force sensors ; Leg ; Mathematical model ; PicoPress ; Pressure measurement ; Transducers ; Ulcers</subject><ispartof>2011 IEEE International Conference on Mechatronics and Automation, 2011, p.289-294</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5985672$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27924,54554,54919,54931</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5985672$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Al Khaburi, J.</creatorcontrib><creatorcontrib>Dehghani-Sanij, A. A.</creatorcontrib><creatorcontrib>Nelson, E. A.</creatorcontrib><creatorcontrib>Hutchinson, J.</creatorcontrib><title>Measurement of interface pressure applied by medical compression bandages</title><title>2011 IEEE International Conference on Mechatronics and Automation</title><addtitle>ICMA</addtitle><description>Medical compression bandages (MCBs) are widely used to treat venous leg ulcers. Interface pressure measurement devices like PicoPress® transducer are used occasionally to measure the pressure applied by MCBs to train nurses to apply MCBs with the correct pressure profile to patient's leg and for quality assurance purposes. However, most of these devices provide only single point pressure measurement. Some of them like the Medical Stocking Tester (MST) and the Oxford Pressure Monitoring MK can provide multiple points of pressure measurement simultaneously. However, the current available systems cannot map the pressures applied by MCBs to a leg at 16 or more points simultaneously. Flexible sensors like FlexiForce® seem to provide a good alternative to current pressure measurement system. This paper will report on the work carried out to compare the pressure measured using FlexiForce® force sensors with the pressures measured using PicoPress®, which is a pneumatic transducer, and FS01 force sensor, which is an ultra profile rigid MEMS force sensor. In addition, it will compare the pressures measured using the three sensing transducers with the pressures computed from the amount of extension in the MCB, which is applied to the medium which these sensors are attached to.</description><subject>Biomedical measurements</subject><subject>Compression</subject><subject>FlexiForce</subject><subject>Force Sensor</subject><subject>Force sensors</subject><subject>Leg</subject><subject>Mathematical model</subject><subject>PicoPress</subject><subject>Pressure measurement</subject><subject>Transducers</subject><subject>Ulcers</subject><issn>2152-7431</issn><issn>2152-744X</issn><isbn>9781424481132</isbn><isbn>1424481139</isbn><isbn>1424481147</isbn><isbn>9781424481149</isbn><isbn>1424481155</isbn><isbn>9781424481156</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo90MtOwzAQBVDzkiglH4DY-AcS_IqdWVYRj0it2HTBrrLjMTJK0igOi_49BQqzuYsjXekOIXecFZwzeGjqzaoQjPOihKrURpyRG66EUhXnypyTheClyI1SbxckA1P9mRSX_yb5NclS-mDH0xpAiAVpNmjT54Q9DjPdBxqHGadgW6TjhOlbqB3HLqKn7kB79LG1HW33_Q_H_UCdHbx9x3RLroLtEmanXJLt0-O2fsnXr89NvVrnEdicSwlOaMYkWlNa5oAredwjXKi0M07qygdjvPYlSO28Nq1gCM5LsEGB9nJJ7n9rIyLuxin2djrsTk-RX0I4UZM</recordid><startdate>201108</startdate><enddate>201108</enddate><creator>Al Khaburi, J.</creator><creator>Dehghani-Sanij, A. A.</creator><creator>Nelson, E. A.</creator><creator>Hutchinson, J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201108</creationdate><title>Measurement of interface pressure applied by medical compression bandages</title><author>Al Khaburi, J. ; Dehghani-Sanij, A. A. ; Nelson, E. A. ; Hutchinson, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-339b26003ea75a0b91438562bf86b7b368df77d6d5936bd67c20e9bd39af496d3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Biomedical measurements</topic><topic>Compression</topic><topic>FlexiForce</topic><topic>Force Sensor</topic><topic>Force sensors</topic><topic>Leg</topic><topic>Mathematical model</topic><topic>PicoPress</topic><topic>Pressure measurement</topic><topic>Transducers</topic><topic>Ulcers</topic><toplevel>online_resources</toplevel><creatorcontrib>Al Khaburi, J.</creatorcontrib><creatorcontrib>Dehghani-Sanij, A. A.</creatorcontrib><creatorcontrib>Nelson, E. A.</creatorcontrib><creatorcontrib>Hutchinson, J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Al Khaburi, J.</au><au>Dehghani-Sanij, A. A.</au><au>Nelson, E. A.</au><au>Hutchinson, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Measurement of interface pressure applied by medical compression bandages</atitle><btitle>2011 IEEE International Conference on Mechatronics and Automation</btitle><stitle>ICMA</stitle><date>2011-08</date><risdate>2011</risdate><spage>289</spage><epage>294</epage><pages>289-294</pages><issn>2152-7431</issn><eissn>2152-744X</eissn><isbn>9781424481132</isbn><isbn>1424481139</isbn><eisbn>1424481147</eisbn><eisbn>9781424481149</eisbn><eisbn>1424481155</eisbn><eisbn>9781424481156</eisbn><abstract>Medical compression bandages (MCBs) are widely used to treat venous leg ulcers. Interface pressure measurement devices like PicoPress® transducer are used occasionally to measure the pressure applied by MCBs to train nurses to apply MCBs with the correct pressure profile to patient's leg and for quality assurance purposes. However, most of these devices provide only single point pressure measurement. Some of them like the Medical Stocking Tester (MST) and the Oxford Pressure Monitoring MK can provide multiple points of pressure measurement simultaneously. However, the current available systems cannot map the pressures applied by MCBs to a leg at 16 or more points simultaneously. Flexible sensors like FlexiForce® seem to provide a good alternative to current pressure measurement system. This paper will report on the work carried out to compare the pressure measured using FlexiForce® force sensors with the pressures measured using PicoPress®, which is a pneumatic transducer, and FS01 force sensor, which is an ultra profile rigid MEMS force sensor. In addition, it will compare the pressures measured using the three sensing transducers with the pressures computed from the amount of extension in the MCB, which is applied to the medium which these sensors are attached to.</abstract><pub>IEEE</pub><doi>10.1109/ICMA.2011.5985672</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2152-7431
ispartof 2011 IEEE International Conference on Mechatronics and Automation, 2011, p.289-294
issn 2152-7431
2152-744X
language eng
recordid cdi_ieee_primary_5985672
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Biomedical measurements
Compression
FlexiForce
Force Sensor
Force sensors
Leg
Mathematical model
PicoPress
Pressure measurement
Transducers
Ulcers
title Measurement of interface pressure applied by medical compression bandages
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T00%3A21%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Measurement%20of%20interface%20pressure%20applied%20by%20medical%20compression%20bandages&rft.btitle=2011%20IEEE%20International%20Conference%20on%20Mechatronics%20and%20Automation&rft.au=Al%20Khaburi,%20J.&rft.date=2011-08&rft.spage=289&rft.epage=294&rft.pages=289-294&rft.issn=2152-7431&rft.eissn=2152-744X&rft.isbn=9781424481132&rft.isbn_list=1424481139&rft_id=info:doi/10.1109/ICMA.2011.5985672&rft.eisbn=1424481147&rft.eisbn_list=9781424481149&rft.eisbn_list=1424481155&rft.eisbn_list=9781424481156&rft_dat=%3Cieee_6IE%3E5985672%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i90t-339b26003ea75a0b91438562bf86b7b368df77d6d5936bd67c20e9bd39af496d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5985672&rfr_iscdi=true