Graphical user interface for enhanced retinal image analysis for diagnosing diabetic retinopathy
Diabetic Retinopathy is a severe eye disease caused due to chronic diabetes. The project aims at developing a novel solution for easy diagnosis of Diabetic Retinopathy, which is a serious condition prevailing among the diabetic patients. The literature study reveals that, direct inspection of retina...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 613 |
container_issue | |
container_start_page | 610 |
container_title | |
container_volume | |
creator | Venkatalakshmi, B. Saravanan, V. Niveditha, G. J. |
description | Diabetic Retinopathy is a severe eye disease caused due to chronic diabetes. The project aims at developing a novel solution for easy diagnosis of Diabetic Retinopathy, which is a serious condition prevailing among the diabetic patients. The literature study reveals that, direct inspection of retinal image captured by fundus camera is not sufficient for the diagnosis of diabetic retinopathy at initial stages and also requires periodic screening which is a time consuming process. Instead if the image is processed and relevant parameters such as hard exudates are detected based on its features like sharp edges and color are highlighted by the implementation of image processing techniques and the graphical user interface created using MATLAB 7.8, will aid the physicians in quick examination. The methodology involves extraction of optic disc (OD) which is a feature found in retina is carried out as a initial stage of extracting hard exudates which is followed by detection of yellowish objects and sharp edged objects. Finally each process involved in detecting hard exudates take up a icon in a single window called Graphical User Interface(GUI) window which will be an exclusive window for detecting hard exudates. The processed resultant image can be examined comfortably at its earlier stages and thus reducing the examining time. |
doi_str_mv | 10.1109/ICCSN.2011.6014967 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6014967</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6014967</ieee_id><sourcerecordid>6014967</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-6b84be1e581d5bd7dc73afff7aefdb623b4f724996859bc3d94e16daf533e9153</originalsourceid><addsrcrecordid>eNo1kMtOwzAQRY0QElDyA7DJDyTY8XuJImgrVbCg-2LH48SoJJEdFvl7Ai2zuedKR6PRIHRPcEkI1o_bun5_LStMSCkwYVrIC3RLBKkUY0rQS5Rpqf4759coS-kTLyOE0ljeoI91NGMXGnPMvxPEPPQTRG8ayP0Qc-g70zfg8ghT6BcnfJkWcrPgnEL6c1wwbT-k0Le_aBexOenDaKZuvkNX3hwTZOdcof3L877eFLu39bZ-2hVB46kQVjELBLgijlsnXSOp8d5LA95ZUVHLvKyY1kJxbRvqNAMinPGcUtCE0xV6OK0NAHAY43JonA_nn9AfQeNX8A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Graphical user interface for enhanced retinal image analysis for diagnosing diabetic retinopathy</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Venkatalakshmi, B. ; Saravanan, V. ; Niveditha, G. J.</creator><creatorcontrib>Venkatalakshmi, B. ; Saravanan, V. ; Niveditha, G. J.</creatorcontrib><description>Diabetic Retinopathy is a severe eye disease caused due to chronic diabetes. The project aims at developing a novel solution for easy diagnosis of Diabetic Retinopathy, which is a serious condition prevailing among the diabetic patients. The literature study reveals that, direct inspection of retinal image captured by fundus camera is not sufficient for the diagnosis of diabetic retinopathy at initial stages and also requires periodic screening which is a time consuming process. Instead if the image is processed and relevant parameters such as hard exudates are detected based on its features like sharp edges and color are highlighted by the implementation of image processing techniques and the graphical user interface created using MATLAB 7.8, will aid the physicians in quick examination. The methodology involves extraction of optic disc (OD) which is a feature found in retina is carried out as a initial stage of extracting hard exudates which is followed by detection of yellowish objects and sharp edged objects. Finally each process involved in detecting hard exudates take up a icon in a single window called Graphical User Interface(GUI) window which will be an exclusive window for detecting hard exudates. The processed resultant image can be examined comfortably at its earlier stages and thus reducing the examining time.</description><identifier>ISBN: 9781612844855</identifier><identifier>ISBN: 1612844855</identifier><identifier>EISBN: 1612844863</identifier><identifier>EISBN: 1612844847</identifier><identifier>EISBN: 9781612844848</identifier><identifier>EISBN: 9781612844862</identifier><identifier>DOI: 10.1109/ICCSN.2011.6014967</identifier><language>eng</language><publisher>IEEE</publisher><subject>Diabetic retinopathy ; Graphical User Interface ; Graphical user interfaces ; hard exudates ; Image color analysis ; Image edge detection ; image processing ; Lead ; Monitoring ; Retinopathy</subject><ispartof>2011 IEEE 3rd International Conference on Communication Software and Networks, 2011, p.610-613</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6014967$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6014967$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Venkatalakshmi, B.</creatorcontrib><creatorcontrib>Saravanan, V.</creatorcontrib><creatorcontrib>Niveditha, G. J.</creatorcontrib><title>Graphical user interface for enhanced retinal image analysis for diagnosing diabetic retinopathy</title><title>2011 IEEE 3rd International Conference on Communication Software and Networks</title><addtitle>ICCSN</addtitle><description>Diabetic Retinopathy is a severe eye disease caused due to chronic diabetes. The project aims at developing a novel solution for easy diagnosis of Diabetic Retinopathy, which is a serious condition prevailing among the diabetic patients. The literature study reveals that, direct inspection of retinal image captured by fundus camera is not sufficient for the diagnosis of diabetic retinopathy at initial stages and also requires periodic screening which is a time consuming process. Instead if the image is processed and relevant parameters such as hard exudates are detected based on its features like sharp edges and color are highlighted by the implementation of image processing techniques and the graphical user interface created using MATLAB 7.8, will aid the physicians in quick examination. The methodology involves extraction of optic disc (OD) which is a feature found in retina is carried out as a initial stage of extracting hard exudates which is followed by detection of yellowish objects and sharp edged objects. Finally each process involved in detecting hard exudates take up a icon in a single window called Graphical User Interface(GUI) window which will be an exclusive window for detecting hard exudates. The processed resultant image can be examined comfortably at its earlier stages and thus reducing the examining time.</description><subject>Diabetic retinopathy</subject><subject>Graphical User Interface</subject><subject>Graphical user interfaces</subject><subject>hard exudates</subject><subject>Image color analysis</subject><subject>Image edge detection</subject><subject>image processing</subject><subject>Lead</subject><subject>Monitoring</subject><subject>Retinopathy</subject><isbn>9781612844855</isbn><isbn>1612844855</isbn><isbn>1612844863</isbn><isbn>1612844847</isbn><isbn>9781612844848</isbn><isbn>9781612844862</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1kMtOwzAQRY0QElDyA7DJDyTY8XuJImgrVbCg-2LH48SoJJEdFvl7Ai2zuedKR6PRIHRPcEkI1o_bun5_LStMSCkwYVrIC3RLBKkUY0rQS5Rpqf4759coS-kTLyOE0ljeoI91NGMXGnPMvxPEPPQTRG8ayP0Qc-g70zfg8ghT6BcnfJkWcrPgnEL6c1wwbT-k0Le_aBexOenDaKZuvkNX3hwTZOdcof3L877eFLu39bZ-2hVB46kQVjELBLgijlsnXSOp8d5LA95ZUVHLvKyY1kJxbRvqNAMinPGcUtCE0xV6OK0NAHAY43JonA_nn9AfQeNX8A</recordid><startdate>201105</startdate><enddate>201105</enddate><creator>Venkatalakshmi, B.</creator><creator>Saravanan, V.</creator><creator>Niveditha, G. J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201105</creationdate><title>Graphical user interface for enhanced retinal image analysis for diagnosing diabetic retinopathy</title><author>Venkatalakshmi, B. ; Saravanan, V. ; Niveditha, G. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-6b84be1e581d5bd7dc73afff7aefdb623b4f724996859bc3d94e16daf533e9153</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Diabetic retinopathy</topic><topic>Graphical User Interface</topic><topic>Graphical user interfaces</topic><topic>hard exudates</topic><topic>Image color analysis</topic><topic>Image edge detection</topic><topic>image processing</topic><topic>Lead</topic><topic>Monitoring</topic><topic>Retinopathy</topic><toplevel>online_resources</toplevel><creatorcontrib>Venkatalakshmi, B.</creatorcontrib><creatorcontrib>Saravanan, V.</creatorcontrib><creatorcontrib>Niveditha, G. J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library Online</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Venkatalakshmi, B.</au><au>Saravanan, V.</au><au>Niveditha, G. J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Graphical user interface for enhanced retinal image analysis for diagnosing diabetic retinopathy</atitle><btitle>2011 IEEE 3rd International Conference on Communication Software and Networks</btitle><stitle>ICCSN</stitle><date>2011-05</date><risdate>2011</risdate><spage>610</spage><epage>613</epage><pages>610-613</pages><isbn>9781612844855</isbn><isbn>1612844855</isbn><eisbn>1612844863</eisbn><eisbn>1612844847</eisbn><eisbn>9781612844848</eisbn><eisbn>9781612844862</eisbn><abstract>Diabetic Retinopathy is a severe eye disease caused due to chronic diabetes. The project aims at developing a novel solution for easy diagnosis of Diabetic Retinopathy, which is a serious condition prevailing among the diabetic patients. The literature study reveals that, direct inspection of retinal image captured by fundus camera is not sufficient for the diagnosis of diabetic retinopathy at initial stages and also requires periodic screening which is a time consuming process. Instead if the image is processed and relevant parameters such as hard exudates are detected based on its features like sharp edges and color are highlighted by the implementation of image processing techniques and the graphical user interface created using MATLAB 7.8, will aid the physicians in quick examination. The methodology involves extraction of optic disc (OD) which is a feature found in retina is carried out as a initial stage of extracting hard exudates which is followed by detection of yellowish objects and sharp edged objects. Finally each process involved in detecting hard exudates take up a icon in a single window called Graphical User Interface(GUI) window which will be an exclusive window for detecting hard exudates. The processed resultant image can be examined comfortably at its earlier stages and thus reducing the examining time.</abstract><pub>IEEE</pub><doi>10.1109/ICCSN.2011.6014967</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781612844855 |
ispartof | 2011 IEEE 3rd International Conference on Communication Software and Networks, 2011, p.610-613 |
issn | |
language | eng |
recordid | cdi_ieee_primary_6014967 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Diabetic retinopathy Graphical User Interface Graphical user interfaces hard exudates Image color analysis Image edge detection image processing Lead Monitoring Retinopathy |
title | Graphical user interface for enhanced retinal image analysis for diagnosing diabetic retinopathy |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T18%3A55%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Graphical%20user%20interface%20for%20enhanced%20retinal%20image%20analysis%20for%20diagnosing%20diabetic%20retinopathy&rft.btitle=2011%20IEEE%203rd%20International%20Conference%20on%20Communication%20Software%20and%20Networks&rft.au=Venkatalakshmi,%20B.&rft.date=2011-05&rft.spage=610&rft.epage=613&rft.pages=610-613&rft.isbn=9781612844855&rft.isbn_list=1612844855&rft_id=info:doi/10.1109/ICCSN.2011.6014967&rft.eisbn=1612844863&rft.eisbn_list=1612844847&rft.eisbn_list=9781612844848&rft.eisbn_list=9781612844862&rft_dat=%3Cieee_6IE%3E6014967%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i90t-6b84be1e581d5bd7dc73afff7aefdb623b4f724996859bc3d94e16daf533e9153%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6014967&rfr_iscdi=true |