Loading…
Sensors elements for micro-calorimetric measurements
This study deals with the research of new platinum resistance thermometers for micro-calorimetric measurements. The aim of this study is to design a suitable topology of platinum thermometers for a potential micro-calorimetric sensor based on organic materials. The suitable topology of a pair of the...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study deals with the research of new platinum resistance thermometers for micro-calorimetric measurements. The aim of this study is to design a suitable topology of platinum thermometers for a potential micro-calorimetric sensor based on organic materials. The suitable topology of a pair of thermometers was designed for the future micro-calorimetric sensors. Further, various evaluation methods were examined for reading the signal data from the appropriate arrangement of the pair of platinum thermometers. A thorough description of platinum thermometers, measuring procedures, evaluation methods and results of experiments will be presented. |
---|---|
ISSN: | 2161-2528 |
DOI: | 10.1109/ISSE.2011.6053952 |