Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner

Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source arr...

Full description

Saved in:
Bibliographic Details
Main Authors: Kotasidis, F. A., Angelis, G. I., Henderson, J., Buckley, A., Markiewicz, P. J., Green, M., Anton-Rodriguez, J., Lionheart, W. R., Reader, A. J., Matthews, J. C.
Format: Conference Proceeding
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c225t-8936c0a7abbeca32b774dba0e00920c1feaf128129ae00c55ff8e41d1270b02a3
cites
container_end_page 3596
container_issue
container_start_page 3595
container_title
container_volume
creator Kotasidis, F. A.
Angelis, G. I.
Henderson, J.
Buckley, A.
Markiewicz, P. J.
Green, M.
Anton-Rodriguez, J.
Lionheart, W. R.
Reader, A. J.
Matthews, J. C.
description Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15×11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing ~300MBq of carbon-11 at the scan starts (15 × 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by ~1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.
doi_str_mv 10.1109/NSSMIC.2011.6153675
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6153675</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6153675</ieee_id><sourcerecordid>6153675</sourcerecordid><originalsourceid>FETCH-LOGICAL-c225t-8936c0a7abbeca32b774dba0e00920c1feaf128129ae00c55ff8e41d1270b02a3</originalsourceid><addsrcrecordid>eNo9kNtqwzAMhr0TrOv6BL3xC6Sz7DhOLkfp1kJ3oM2ui-LIW0aWhDgt9O3nsjJdSOL74QOJsSmIGYDIHl6325fVfCYFwCwBrRKjL9gdxIlRAqTQl2wktTGRSGV29R9Aqq7ZCAKMVKLjWzbx_luESpIsjvWI-cUB6z0OVdvw1vHqBz-JF-ip5L4LGOv6yA_YV9gMHJuS23Yfth4H4iV11JSnoGur0H3XE5bc7Rt78nkenMMX8eVmk_P3Rc69xaah_p7dOKw9Tc5zzD6eFvl8Ga3fnlfzx3VkpdRDlGYqsQINFgVZVLIwJi4LFCREJoUFR-hApiAzDMhq7VxKMZQgjSiERDVm0z9vRUS7rg_H9cfd-XnqF_YYYMA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Kotasidis, F. A. ; Angelis, G. I. ; Henderson, J. ; Buckley, A. ; Markiewicz, P. J. ; Green, M. ; Anton-Rodriguez, J. ; Lionheart, W. R. ; Reader, A. J. ; Matthews, J. C.</creator><creatorcontrib>Kotasidis, F. A. ; Angelis, G. I. ; Henderson, J. ; Buckley, A. ; Markiewicz, P. J. ; Green, M. ; Anton-Rodriguez, J. ; Lionheart, W. R. ; Reader, A. J. ; Matthews, J. C.</creatorcontrib><description>Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15×11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing ~300MBq of carbon-11 at the scan starts (15 × 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by ~1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 1467301183</identifier><identifier>ISBN: 9781467301183</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 1467301205</identifier><identifier>EISBN: 1467301191</identifier><identifier>EISBN: 9781467301206</identifier><identifier>EISBN: 9781467301190</identifier><identifier>DOI: 10.1109/NSSMIC.2011.6153675</identifier><language>eng</language><publisher>IEEE</publisher><subject>Degradation ; Image resolution ; Positron emission tomography</subject><ispartof>2011 IEEE Nuclear Science Symposium Conference Record, 2011, p.3595-3596</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c225t-8936c0a7abbeca32b774dba0e00920c1feaf128129ae00c55ff8e41d1270b02a3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6153675$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,778,782,787,788,2054,27908,54538,54903,54915</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6153675$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kotasidis, F. A.</creatorcontrib><creatorcontrib>Angelis, G. I.</creatorcontrib><creatorcontrib>Henderson, J.</creatorcontrib><creatorcontrib>Buckley, A.</creatorcontrib><creatorcontrib>Markiewicz, P. J.</creatorcontrib><creatorcontrib>Green, M.</creatorcontrib><creatorcontrib>Anton-Rodriguez, J.</creatorcontrib><creatorcontrib>Lionheart, W. R.</creatorcontrib><creatorcontrib>Reader, A. J.</creatorcontrib><creatorcontrib>Matthews, J. C.</creatorcontrib><title>Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner</title><title>2011 IEEE Nuclear Science Symposium Conference Record</title><addtitle>NSSMIC</addtitle><description>Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15×11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing ~300MBq of carbon-11 at the scan starts (15 × 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by ~1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.</description><subject>Degradation</subject><subject>Image resolution</subject><subject>Positron emission tomography</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>1467301183</isbn><isbn>9781467301183</isbn><isbn>1467301205</isbn><isbn>1467301191</isbn><isbn>9781467301206</isbn><isbn>9781467301190</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo9kNtqwzAMhr0TrOv6BL3xC6Sz7DhOLkfp1kJ3oM2ui-LIW0aWhDgt9O3nsjJdSOL74QOJsSmIGYDIHl6325fVfCYFwCwBrRKjL9gdxIlRAqTQl2wktTGRSGV29R9Aqq7ZCAKMVKLjWzbx_luESpIsjvWI-cUB6z0OVdvw1vHqBz-JF-ip5L4LGOv6yA_YV9gMHJuS23Yfth4H4iV11JSnoGur0H3XE5bc7Rt78nkenMMX8eVmk_P3Rc69xaah_p7dOKw9Tc5zzD6eFvl8Ga3fnlfzx3VkpdRDlGYqsQINFgVZVLIwJi4LFCREJoUFR-hApiAzDMhq7VxKMZQgjSiERDVm0z9vRUS7rg_H9cfd-XnqF_YYYMA</recordid><startdate>201110</startdate><enddate>201110</enddate><creator>Kotasidis, F. A.</creator><creator>Angelis, G. I.</creator><creator>Henderson, J.</creator><creator>Buckley, A.</creator><creator>Markiewicz, P. J.</creator><creator>Green, M.</creator><creator>Anton-Rodriguez, J.</creator><creator>Lionheart, W. R.</creator><creator>Reader, A. J.</creator><creator>Matthews, J. C.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201110</creationdate><title>Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner</title><author>Kotasidis, F. A. ; Angelis, G. I. ; Henderson, J. ; Buckley, A. ; Markiewicz, P. J. ; Green, M. ; Anton-Rodriguez, J. ; Lionheart, W. R. ; Reader, A. J. ; Matthews, J. C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c225t-8936c0a7abbeca32b774dba0e00920c1feaf128129ae00c55ff8e41d1270b02a3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Degradation</topic><topic>Image resolution</topic><topic>Positron emission tomography</topic><toplevel>online_resources</toplevel><creatorcontrib>Kotasidis, F. A.</creatorcontrib><creatorcontrib>Angelis, G. I.</creatorcontrib><creatorcontrib>Henderson, J.</creatorcontrib><creatorcontrib>Buckley, A.</creatorcontrib><creatorcontrib>Markiewicz, P. J.</creatorcontrib><creatorcontrib>Green, M.</creatorcontrib><creatorcontrib>Anton-Rodriguez, J.</creatorcontrib><creatorcontrib>Lionheart, W. R.</creatorcontrib><creatorcontrib>Reader, A. J.</creatorcontrib><creatorcontrib>Matthews, J. C.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kotasidis, F. A.</au><au>Angelis, G. I.</au><au>Henderson, J.</au><au>Buckley, A.</au><au>Markiewicz, P. J.</au><au>Green, M.</au><au>Anton-Rodriguez, J.</au><au>Lionheart, W. R.</au><au>Reader, A. J.</au><au>Matthews, J. C.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner</atitle><btitle>2011 IEEE Nuclear Science Symposium Conference Record</btitle><stitle>NSSMIC</stitle><date>2011-10</date><risdate>2011</risdate><spage>3595</spage><epage>3596</epage><pages>3595-3596</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>1467301183</isbn><isbn>9781467301183</isbn><eisbn>1467301205</eisbn><eisbn>1467301191</eisbn><eisbn>9781467301206</eisbn><eisbn>9781467301190</eisbn><abstract>Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/CT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15×11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing ~300MBq of carbon-11 at the scan starts (15 × 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by ~1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2011.6153675</doi><tpages>2</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2011 IEEE Nuclear Science Symposium Conference Record, 2011, p.3595-3596
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_6153675
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Degradation
Image resolution
Positron emission tomography
title Evaluation of image based spatially variant and count rate dependant point spread functions on the HRRT PET scanner
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T14%3A34%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Evaluation%20of%20image%20based%20spatially%20variant%20and%20count%20rate%20dependant%20point%20spread%20functions%20on%20the%20HRRT%20PET%20scanner&rft.btitle=2011%20IEEE%20Nuclear%20Science%20Symposium%20Conference%20Record&rft.au=Kotasidis,%20F.%20A.&rft.date=2011-10&rft.spage=3595&rft.epage=3596&rft.pages=3595-3596&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=1467301183&rft.isbn_list=9781467301183&rft_id=info:doi/10.1109/NSSMIC.2011.6153675&rft.eisbn=1467301205&rft.eisbn_list=1467301191&rft.eisbn_list=9781467301206&rft.eisbn_list=9781467301190&rft_dat=%3Cieee_6IE%3E6153675%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c225t-8936c0a7abbeca32b774dba0e00920c1feaf128129ae00c55ff8e41d1270b02a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6153675&rfr_iscdi=true