Loading…

Design of supplemental plate for piezoelectric system to distribute impact force

The relationship between deformation degree and curvature to the output voltage of piezoelectric system was analyzed. The calculated data and experimental data were compared. The experiment was held by using tip mass of 10 g, 20 g, and 30 g for the various thickness of piezoelectric material as 0.15...

Full description

Saved in:
Bibliographic Details
Main Authors: Hidaka, S., Jeong Hun Kim, Hyun Jun Jung, Yoo Sub Song, Se Bin Kim, Ki Hwan Baek, Tae Hyun Sung
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The relationship between deformation degree and curvature to the output voltage of piezoelectric system was analyzed. The calculated data and experimental data were compared. The experiment was held by using tip mass of 10 g, 20 g, and 30 g for the various thickness of piezoelectric material as 0.15 mm and 0.2 mm for various type design of supplemental plate. As results, at the vibration acceleration of 4 m/s 2 , the lowest average Ix value was resulted the highest voltage of 26.12 V. However, when the vibration acceleration of 40 m/s2, the lowest standard deviation of curvature ratio, ρ, and resulted the highest voltage of 58.98 V. This study proves that the deformation degree and curvature ration can be controlled.
ISSN:1099-4734
2375-0448
DOI:10.1109/ISAF.2012.6297760