Loading…
String-Level (kW-scale) IV curves from different module types under partial shade
Partial shade is known to cause significant de-rating for most photovoltaic (PV) systems. However, the specific de-rating due to partial shade from differently shaped objects like overhead wires is not well known. We present current-voltage (I-V) curves from three different strings containing 4 to 9...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Partial shade is known to cause significant de-rating for most photovoltaic (PV) systems. However, the specific de-rating due to partial shade from differently shaped objects like overhead wires is not well known. We present current-voltage (I-V) curves from three different strings containing 4 to 9 PV modules while applying various types of partial shade, including shade from electrical cables in front of the modules. We show that a 1-kW string of nine poly-Silicon modules manufactured by Sharp can have a power loss of 13% due to shading just 1% of its surface area. We verify that blocking columns of cells in a module has less impact on power loss than blocking rows. This demonstrates how the non-linear response to partial shade can depend on the placement of bypass diodes that isolate different sub-strings within each module. Furthermore, we quantify the reduction in power and I-V parameters caused by shade from wires (or PVC pipes in our experiments). |
---|---|
ISSN: | 0160-8371 |
DOI: | 10.1109/PVSC.2012.6317868 |