Loading…
Teleprotection simulation lab: Understanding the performance of telecommunication aided protection systems under impaired telecommunication network conditions
Protection using telecommunications, such as the current differential protection schemes, are well known for their selectivity, sensitivity and fast operating times. Such advantages make them a desirable choice for the protection of high voltage transmission lines. However, the reliability and secur...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 660 |
container_issue | |
container_start_page | 655 |
container_title | |
container_volume | |
creator | Yusof, H. A. Musa, A. Ramli, A. Q. Ridwan, M. I. |
description | Protection using telecommunications, such as the current differential protection schemes, are well known for their selectivity, sensitivity and fast operating times. Such advantages make them a desirable choice for the protection of high voltage transmission lines. However, the reliability and security of these protection schemes depends heavily on the performance of the telecommunication network, which itself is subject to various form of impairments. Tenaga Nasional Berhad (TNB), Malaysia's electrical utility company, depends heavily on the use of current differential protection scheme to protect its high voltage transmission lines. Therefore it is very important to understand how these protection schemes behave when the telecommunication network is impaired. Learning by experience, as several tripping incidents have shown, can be very costly and time consuming. By building a teleprotection simulation lab and using it together with a real-time digital simulator for real load and fault conditions, the performance of these protection schemes under an impaired telecommunication network can be examined and studied in much greater detail under a controlled lab environment. This will enhance the learning process and allow proactive measures to be taken before any unwanted incidents occur. |
doi_str_mv | 10.1109/PECon.2012.6450295 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6450295</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6450295</ieee_id><sourcerecordid>6450295</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-51698436b268e5a6367d7e35104710d9d8c99a7f7a4547cb41b5a13638a1f7a13</originalsourceid><addsrcrecordid>eNplkM9KAzEQhyMiqLUvoJe8QGuy-bfxJqVWoaCH9lyy2VmN7iZLkiJ9GZ_Vra0geJqZH_N9A4PQNSVTSom-fZnPgp8WhBZTyQUptDhBl5RLxQShJT9FY63K31nxczRO6Z0QMsCyVOoCfa2ghT6GDDa74HFy3bY1P21rqju89jXElI2vnX_F-Q1wD7EJsTPeAg4NzgNvQ9dtvbMHzrgaavzXuUsZuoS3exd2XW9cHDb-kx7yZ4gf2Ibh3D5JV-isMW2C8bGO0Pphvpo9TpbPi6fZ_XLiqBJ5IqjUJWeyKmQJwkgmVa2ACUq4oqTWdWm1NqpRhguubMVpJQxlkpWGDiFlI3Rz8DoA2PTRdSbuNseXsm9T0m_A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Teleprotection simulation lab: Understanding the performance of telecommunication aided protection systems under impaired telecommunication network conditions</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Yusof, H. A. ; Musa, A. ; Ramli, A. Q. ; Ridwan, M. I.</creator><creatorcontrib>Yusof, H. A. ; Musa, A. ; Ramli, A. Q. ; Ridwan, M. I.</creatorcontrib><description>Protection using telecommunications, such as the current differential protection schemes, are well known for their selectivity, sensitivity and fast operating times. Such advantages make them a desirable choice for the protection of high voltage transmission lines. However, the reliability and security of these protection schemes depends heavily on the performance of the telecommunication network, which itself is subject to various form of impairments. Tenaga Nasional Berhad (TNB), Malaysia's electrical utility company, depends heavily on the use of current differential protection scheme to protect its high voltage transmission lines. Therefore it is very important to understand how these protection schemes behave when the telecommunication network is impaired. Learning by experience, as several tripping incidents have shown, can be very costly and time consuming. By building a teleprotection simulation lab and using it together with a real-time digital simulator for real load and fault conditions, the performance of these protection schemes under an impaired telecommunication network can be examined and studied in much greater detail under a controlled lab environment. This will enhance the learning process and allow proactive measures to be taken before any unwanted incidents occur.</description><identifier>ISBN: 9781467350174</identifier><identifier>ISBN: 1467350176</identifier><identifier>EISBN: 1467350184</identifier><identifier>EISBN: 9781467350181</identifier><identifier>EISBN: 9781467350198</identifier><identifier>EISBN: 1467350192</identifier><identifier>DOI: 10.1109/PECon.2012.6450295</identifier><language>eng</language><publisher>IEEE</publisher><subject>Current differential protection ; Delay ; IEC standards ; Laboratories ; Relays ; Reliability ; Simulation lab ; Synchronous digital hierarchy ; Teleprotection</subject><ispartof>2012 IEEE International Conference on Power and Energy (PECon), 2012, p.655-660</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6450295$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6450295$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Yusof, H. A.</creatorcontrib><creatorcontrib>Musa, A.</creatorcontrib><creatorcontrib>Ramli, A. Q.</creatorcontrib><creatorcontrib>Ridwan, M. I.</creatorcontrib><title>Teleprotection simulation lab: Understanding the performance of telecommunication aided protection systems under impaired telecommunication network conditions</title><title>2012 IEEE International Conference on Power and Energy (PECon)</title><addtitle>PECon</addtitle><description>Protection using telecommunications, such as the current differential protection schemes, are well known for their selectivity, sensitivity and fast operating times. Such advantages make them a desirable choice for the protection of high voltage transmission lines. However, the reliability and security of these protection schemes depends heavily on the performance of the telecommunication network, which itself is subject to various form of impairments. Tenaga Nasional Berhad (TNB), Malaysia's electrical utility company, depends heavily on the use of current differential protection scheme to protect its high voltage transmission lines. Therefore it is very important to understand how these protection schemes behave when the telecommunication network is impaired. Learning by experience, as several tripping incidents have shown, can be very costly and time consuming. By building a teleprotection simulation lab and using it together with a real-time digital simulator for real load and fault conditions, the performance of these protection schemes under an impaired telecommunication network can be examined and studied in much greater detail under a controlled lab environment. This will enhance the learning process and allow proactive measures to be taken before any unwanted incidents occur.</description><subject>Current differential protection</subject><subject>Delay</subject><subject>IEC standards</subject><subject>Laboratories</subject><subject>Relays</subject><subject>Reliability</subject><subject>Simulation lab</subject><subject>Synchronous digital hierarchy</subject><subject>Teleprotection</subject><isbn>9781467350174</isbn><isbn>1467350176</isbn><isbn>1467350184</isbn><isbn>9781467350181</isbn><isbn>9781467350198</isbn><isbn>1467350192</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2012</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNplkM9KAzEQhyMiqLUvoJe8QGuy-bfxJqVWoaCH9lyy2VmN7iZLkiJ9GZ_Vra0geJqZH_N9A4PQNSVTSom-fZnPgp8WhBZTyQUptDhBl5RLxQShJT9FY63K31nxczRO6Z0QMsCyVOoCfa2ghT6GDDa74HFy3bY1P21rqju89jXElI2vnX_F-Q1wD7EJsTPeAg4NzgNvQ9dtvbMHzrgaavzXuUsZuoS3exd2XW9cHDb-kx7yZ4gf2Ibh3D5JV-isMW2C8bGO0Pphvpo9TpbPi6fZ_XLiqBJ5IqjUJWeyKmQJwkgmVa2ACUq4oqTWdWm1NqpRhguubMVpJQxlkpWGDiFlI3Rz8DoA2PTRdSbuNseXsm9T0m_A</recordid><startdate>201212</startdate><enddate>201212</enddate><creator>Yusof, H. A.</creator><creator>Musa, A.</creator><creator>Ramli, A. Q.</creator><creator>Ridwan, M. I.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201212</creationdate><title>Teleprotection simulation lab: Understanding the performance of telecommunication aided protection systems under impaired telecommunication network conditions</title><author>Yusof, H. A. ; Musa, A. ; Ramli, A. Q. ; Ridwan, M. I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-51698436b268e5a6367d7e35104710d9d8c99a7f7a4547cb41b5a13638a1f7a13</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Current differential protection</topic><topic>Delay</topic><topic>IEC standards</topic><topic>Laboratories</topic><topic>Relays</topic><topic>Reliability</topic><topic>Simulation lab</topic><topic>Synchronous digital hierarchy</topic><topic>Teleprotection</topic><toplevel>online_resources</toplevel><creatorcontrib>Yusof, H. A.</creatorcontrib><creatorcontrib>Musa, A.</creatorcontrib><creatorcontrib>Ramli, A. Q.</creatorcontrib><creatorcontrib>Ridwan, M. I.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore (Online service)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Yusof, H. A.</au><au>Musa, A.</au><au>Ramli, A. Q.</au><au>Ridwan, M. I.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Teleprotection simulation lab: Understanding the performance of telecommunication aided protection systems under impaired telecommunication network conditions</atitle><btitle>2012 IEEE International Conference on Power and Energy (PECon)</btitle><stitle>PECon</stitle><date>2012-12</date><risdate>2012</risdate><spage>655</spage><epage>660</epage><pages>655-660</pages><isbn>9781467350174</isbn><isbn>1467350176</isbn><eisbn>1467350184</eisbn><eisbn>9781467350181</eisbn><eisbn>9781467350198</eisbn><eisbn>1467350192</eisbn><abstract>Protection using telecommunications, such as the current differential protection schemes, are well known for their selectivity, sensitivity and fast operating times. Such advantages make them a desirable choice for the protection of high voltage transmission lines. However, the reliability and security of these protection schemes depends heavily on the performance of the telecommunication network, which itself is subject to various form of impairments. Tenaga Nasional Berhad (TNB), Malaysia's electrical utility company, depends heavily on the use of current differential protection scheme to protect its high voltage transmission lines. Therefore it is very important to understand how these protection schemes behave when the telecommunication network is impaired. Learning by experience, as several tripping incidents have shown, can be very costly and time consuming. By building a teleprotection simulation lab and using it together with a real-time digital simulator for real load and fault conditions, the performance of these protection schemes under an impaired telecommunication network can be examined and studied in much greater detail under a controlled lab environment. This will enhance the learning process and allow proactive measures to be taken before any unwanted incidents occur.</abstract><pub>IEEE</pub><doi>10.1109/PECon.2012.6450295</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9781467350174 |
ispartof | 2012 IEEE International Conference on Power and Energy (PECon), 2012, p.655-660 |
issn | |
language | eng |
recordid | cdi_ieee_primary_6450295 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Current differential protection Delay IEC standards Laboratories Relays Reliability Simulation lab Synchronous digital hierarchy Teleprotection |
title | Teleprotection simulation lab: Understanding the performance of telecommunication aided protection systems under impaired telecommunication network conditions |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T12%3A03%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Teleprotection%20simulation%20lab:%20Understanding%20the%20performance%20of%20telecommunication%20aided%20protection%20systems%20under%20impaired%20telecommunication%20network%20conditions&rft.btitle=2012%20IEEE%20International%20Conference%20on%20Power%20and%20Energy%20(PECon)&rft.au=Yusof,%20H.%20A.&rft.date=2012-12&rft.spage=655&rft.epage=660&rft.pages=655-660&rft.isbn=9781467350174&rft.isbn_list=1467350176&rft_id=info:doi/10.1109/PECon.2012.6450295&rft.eisbn=1467350184&rft.eisbn_list=9781467350181&rft.eisbn_list=9781467350198&rft.eisbn_list=1467350192&rft_dat=%3Cieee_6IE%3E6450295%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-51698436b268e5a6367d7e35104710d9d8c99a7f7a4547cb41b5a13638a1f7a13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6450295&rfr_iscdi=true |