Loading…

A modified LLCL-filter with the reduced conducted EMI noise

For a transformerless grid-tied converter using Pulse Width Modulation (PWM), the harmonics of grid-injected current, the leakage current and the Electromagnetic Interference (EMI) noise are three important issues during design of the output filter. In this paper, the Common-Mode (CM) and the Differ...

Full description

Saved in:
Bibliographic Details
Main Authors: Weimin Wu, Yunjie Sun, Zhe Lin, Min Huang, Blaabjerg, Frede, Chung, Henry Shu-hung
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:For a transformerless grid-tied converter using Pulse Width Modulation (PWM), the harmonics of grid-injected current, the leakage current and the Electromagnetic Interference (EMI) noise are three important issues during design of the output filter. In this paper, the Common-Mode (CM) and the Differential-Mode (DM) EMI noises are investigated for the LCL- and LLCL-filters based single-phase full-bridge grid-tied inverter. Based on this, a modified LLCL-filter topology is proposed to provide enough attenuation on the conducted EMI noise as well as to reduce the DC-side leakage current. The parameter design method of the filter is also developed. The comparative analysis and discussion on four filter cases (the conventional LCL-filter, the conventional LLCL-filter, the modified LCL-filter, and the modified LLCL-filter) are carried out and verified through simulations and experiments on a 0.5 kW, 110 V / 50 Hz single-phase full-bridge grid-tied inverter prototype.
DOI:10.1109/EPE.2013.6634408