Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging

This paper discusses initial imaging results from a high-resolution time-of-flight detector specifically developed for a limited-angle dedicated breast PET scanner. To maintain high spatial-resolution and sensitivity, the detector design consists of 32 × 32 array of 1.5 × 1.5 × 15 mm 3 LYSO crystals...

Full description

Saved in:
Bibliographic Details
Main Authors: Krishnamoorthy, Srilalan, Werner, Matthew E., LeGeyt, Benjamin, Kaul, Madhuri, Karp, Joel S., Surti, Suleman
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 6
container_issue
container_start_page 1
container_title
container_volume
creator Krishnamoorthy, Srilalan
Werner, Matthew E.
LeGeyt, Benjamin
Kaul, Madhuri
Karp, Joel S.
Surti, Suleman
description This paper discusses initial imaging results from a high-resolution time-of-flight detector specifically developed for a limited-angle dedicated breast PET scanner. To maintain high spatial-resolution and sensitivity, the detector design consists of 32 × 32 array of 1.5 × 1.5 × 15 mm 3 LYSO crystals coupled to a single Hamamatsu H8500 multi-anode photomultiplier tube with a modified high-voltage divider circuit. To minimize the number of readout channels, compact front-end electronics that summed anode-signals along each of the orthogonal directions was also developed. Experimental performance evaluation of a complete detector-module demonstrates excellent energy, timing resolution and clear discrimination of most crystals. An average energy resolution of about 12.7% FWHM and an average coincidence timing resolution of 348 ps for two such detectors was measured. The dedicated breast PET scanner comprises of two parallel detector heads, each 15 cm by 10 cm and comprised of two rows of three detector-modules. We also experimentally evaluated the imaging capability of the scanner design via an experimental benchtop-demonstrator consisting of two fully assembled detector-modules on opposing translational stages. Imaging experiments with a hot lesion phantom that had an 8-mm diameter lesion with 8:1 activity uptake ratio, successfully demonstrate the capability of the system in imaging small lesions in a uniform background.
doi_str_mv 10.1109/NSSMIC.2013.6829091
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_6829091</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6829091</ieee_id><sourcerecordid>6829091</sourcerecordid><originalsourceid>FETCH-LOGICAL-i208t-b61b644a8994c711926970830b925adb7fb0f776057c950ae53706f495f47e7d3</originalsourceid><addsrcrecordid>eNo1UNtOwzAUCwgkqrEv2Et-IOPk1tM8omnApHGRNp6ntE26oK6dmkyCv6fAeLItW7ZkQmYc5pyDuXvZbJ5Xi7kALud5IQwYfkGmBguu0BjQUhWXJBMakcFoX5GMj8hkrtUNmcb4AQAcUSjBM_K56kIKtqXhYJvQNXRw8dSmSP3QH6il-9DsaTzanwwbvb49pdB3NIWDY71nvh0Dib4tt7R2yVWpH0YSQ9O5mvpfUYfKplGVg7Mx_Q_dkmtv2-imZ5yQ94fldvHE1q-Pq8X9mgUBRWJlzstcKVsYoyrk3IjcIBQSSiO0rUv0JXjEHDRWRoN1WiLkXhntFTqs5YTM_nqDc253HMb54Wt3_k1-Ay0PYIw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging</title><source>IEEE Xplore All Conference Series</source><creator>Krishnamoorthy, Srilalan ; Werner, Matthew E. ; LeGeyt, Benjamin ; Kaul, Madhuri ; Karp, Joel S. ; Surti, Suleman</creator><creatorcontrib>Krishnamoorthy, Srilalan ; Werner, Matthew E. ; LeGeyt, Benjamin ; Kaul, Madhuri ; Karp, Joel S. ; Surti, Suleman</creatorcontrib><description>This paper discusses initial imaging results from a high-resolution time-of-flight detector specifically developed for a limited-angle dedicated breast PET scanner. To maintain high spatial-resolution and sensitivity, the detector design consists of 32 × 32 array of 1.5 × 1.5 × 15 mm 3 LYSO crystals coupled to a single Hamamatsu H8500 multi-anode photomultiplier tube with a modified high-voltage divider circuit. To minimize the number of readout channels, compact front-end electronics that summed anode-signals along each of the orthogonal directions was also developed. Experimental performance evaluation of a complete detector-module demonstrates excellent energy, timing resolution and clear discrimination of most crystals. An average energy resolution of about 12.7% FWHM and an average coincidence timing resolution of 348 ps for two such detectors was measured. The dedicated breast PET scanner comprises of two parallel detector heads, each 15 cm by 10 cm and comprised of two rows of three detector-modules. We also experimentally evaluated the imaging capability of the scanner design via an experimental benchtop-demonstrator consisting of two fully assembled detector-modules on opposing translational stages. Imaging experiments with a hot lesion phantom that had an 8-mm diameter lesion with 8:1 activity uptake ratio, successfully demonstrate the capability of the system in imaging small lesions in a uniform background.</description><identifier>ISSN: 1082-3654</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 9781479905348</identifier><identifier>EISBN: 9781479905331</identifier><identifier>EISBN: 1479905348</identifier><identifier>EISBN: 147990533X</identifier><identifier>DOI: 10.1109/NSSMIC.2013.6829091</identifier><language>eng</language><publisher>IEEE</publisher><subject>Anodes ; Arrays ; Crystals ; Detectors ; Energy resolution ; Timing</subject><ispartof>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-6</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6829091$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54555,54920,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6829091$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Krishnamoorthy, Srilalan</creatorcontrib><creatorcontrib>Werner, Matthew E.</creatorcontrib><creatorcontrib>LeGeyt, Benjamin</creatorcontrib><creatorcontrib>Kaul, Madhuri</creatorcontrib><creatorcontrib>Karp, Joel S.</creatorcontrib><creatorcontrib>Surti, Suleman</creatorcontrib><title>Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging</title><title>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</title><addtitle>NSSMIC</addtitle><description>This paper discusses initial imaging results from a high-resolution time-of-flight detector specifically developed for a limited-angle dedicated breast PET scanner. To maintain high spatial-resolution and sensitivity, the detector design consists of 32 × 32 array of 1.5 × 1.5 × 15 mm 3 LYSO crystals coupled to a single Hamamatsu H8500 multi-anode photomultiplier tube with a modified high-voltage divider circuit. To minimize the number of readout channels, compact front-end electronics that summed anode-signals along each of the orthogonal directions was also developed. Experimental performance evaluation of a complete detector-module demonstrates excellent energy, timing resolution and clear discrimination of most crystals. An average energy resolution of about 12.7% FWHM and an average coincidence timing resolution of 348 ps for two such detectors was measured. The dedicated breast PET scanner comprises of two parallel detector heads, each 15 cm by 10 cm and comprised of two rows of three detector-modules. We also experimentally evaluated the imaging capability of the scanner design via an experimental benchtop-demonstrator consisting of two fully assembled detector-modules on opposing translational stages. Imaging experiments with a hot lesion phantom that had an 8-mm diameter lesion with 8:1 activity uptake ratio, successfully demonstrate the capability of the system in imaging small lesions in a uniform background.</description><subject>Anodes</subject><subject>Arrays</subject><subject>Crystals</subject><subject>Detectors</subject><subject>Energy resolution</subject><subject>Timing</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>9781479905348</isbn><isbn>9781479905331</isbn><isbn>1479905348</isbn><isbn>147990533X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1UNtOwzAUCwgkqrEv2Et-IOPk1tM8omnApHGRNp6ntE26oK6dmkyCv6fAeLItW7ZkQmYc5pyDuXvZbJ5Xi7kALud5IQwYfkGmBguu0BjQUhWXJBMakcFoX5GMj8hkrtUNmcb4AQAcUSjBM_K56kIKtqXhYJvQNXRw8dSmSP3QH6il-9DsaTzanwwbvb49pdB3NIWDY71nvh0Dib4tt7R2yVWpH0YSQ9O5mvpfUYfKplGVg7Mx_Q_dkmtv2-imZ5yQ94fldvHE1q-Pq8X9mgUBRWJlzstcKVsYoyrk3IjcIBQSSiO0rUv0JXjEHDRWRoN1WiLkXhntFTqs5YTM_nqDc253HMb54Wt3_k1-Ay0PYIw</recordid><startdate>20131001</startdate><enddate>20131001</enddate><creator>Krishnamoorthy, Srilalan</creator><creator>Werner, Matthew E.</creator><creator>LeGeyt, Benjamin</creator><creator>Kaul, Madhuri</creator><creator>Karp, Joel S.</creator><creator>Surti, Suleman</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20131001</creationdate><title>Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging</title><author>Krishnamoorthy, Srilalan ; Werner, Matthew E. ; LeGeyt, Benjamin ; Kaul, Madhuri ; Karp, Joel S. ; Surti, Suleman</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i208t-b61b644a8994c711926970830b925adb7fb0f776057c950ae53706f495f47e7d3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Anodes</topic><topic>Arrays</topic><topic>Crystals</topic><topic>Detectors</topic><topic>Energy resolution</topic><topic>Timing</topic><toplevel>online_resources</toplevel><creatorcontrib>Krishnamoorthy, Srilalan</creatorcontrib><creatorcontrib>Werner, Matthew E.</creatorcontrib><creatorcontrib>LeGeyt, Benjamin</creatorcontrib><creatorcontrib>Kaul, Madhuri</creatorcontrib><creatorcontrib>Karp, Joel S.</creatorcontrib><creatorcontrib>Surti, Suleman</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Krishnamoorthy, Srilalan</au><au>Werner, Matthew E.</au><au>LeGeyt, Benjamin</au><au>Kaul, Madhuri</au><au>Karp, Joel S.</au><au>Surti, Suleman</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging</atitle><btitle>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</btitle><stitle>NSSMIC</stitle><date>2013-10-01</date><risdate>2013</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><eisbn>9781479905348</eisbn><eisbn>9781479905331</eisbn><eisbn>1479905348</eisbn><eisbn>147990533X</eisbn><abstract>This paper discusses initial imaging results from a high-resolution time-of-flight detector specifically developed for a limited-angle dedicated breast PET scanner. To maintain high spatial-resolution and sensitivity, the detector design consists of 32 × 32 array of 1.5 × 1.5 × 15 mm 3 LYSO crystals coupled to a single Hamamatsu H8500 multi-anode photomultiplier tube with a modified high-voltage divider circuit. To minimize the number of readout channels, compact front-end electronics that summed anode-signals along each of the orthogonal directions was also developed. Experimental performance evaluation of a complete detector-module demonstrates excellent energy, timing resolution and clear discrimination of most crystals. An average energy resolution of about 12.7% FWHM and an average coincidence timing resolution of 348 ps for two such detectors was measured. The dedicated breast PET scanner comprises of two parallel detector heads, each 15 cm by 10 cm and comprised of two rows of three detector-modules. We also experimentally evaluated the imaging capability of the scanner design via an experimental benchtop-demonstrator consisting of two fully assembled detector-modules on opposing translational stages. Imaging experiments with a hot lesion phantom that had an 8-mm diameter lesion with 8:1 activity uptake ratio, successfully demonstrate the capability of the system in imaging small lesions in a uniform background.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2013.6829091</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-6
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_6829091
source IEEE Xplore All Conference Series
subjects Anodes
Arrays
Crystals
Detectors
Energy resolution
Timing
title Initial imaging results from a high spatial-resolution time-of-flight PET detector designed for dedicated breast imaging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T01%3A38%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Initial%20imaging%20results%20from%20a%20high%20spatial-resolution%20time-of-flight%20PET%20detector%20designed%20for%20dedicated%20breast%20imaging&rft.btitle=2013%20IEEE%20Nuclear%20Science%20Symposium%20and%20Medical%20Imaging%20Conference%20(2013%20NSS/MIC)&rft.au=Krishnamoorthy,%20Srilalan&rft.date=2013-10-01&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=1082-3654&rft.eissn=2577-0829&rft_id=info:doi/10.1109/NSSMIC.2013.6829091&rft.eisbn=9781479905348&rft.eisbn_list=9781479905331&rft.eisbn_list=1479905348&rft.eisbn_list=147990533X&rft_dat=%3Cieee_CHZPO%3E6829091%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i208t-b61b644a8994c711926970830b925adb7fb0f776057c950ae53706f495f47e7d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6829091&rfr_iscdi=true