Development of optoelectronic system for subdural hematoma diagnostics

In this paper the modern optical techniques for intracranial traumas diagnosis are presented. The main attention is paid to the near-infrared spectroscopy as the most reasonable and effective technique in case of emergency diagnostics. The existing devices based on this operating principle and their...

Full description

Saved in:
Bibliographic Details
Main Authors: Timchenko, Kristina A., Aristov, Alexander A., Musorov, Ilya S., Evtushenko, Tatyana G.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 322
container_issue
container_start_page 319
container_title
container_volume
creator Timchenko, Kristina A.
Aristov, Alexander A.
Musorov, Ilya S.
Evtushenko, Tatyana G.
description In this paper the modern optical techniques for intracranial traumas diagnosis are presented. The main attention is paid to the near-infrared spectroscopy as the most reasonable and effective technique in case of emergency diagnostics. The existing devices based on this operating principle and their limitations are discussed. Moreover, the proposed experimental setup for the diagnosis of hematoma and its localization, several limitations of the device and possible ways of upgrading the system are discussed. The principle of designing a physical phantom of a head with a hematoma, which parameters can be changed by an operator, is also presented.
doi_str_mv 10.1109/EDM.2014.6882538
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_6882538</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6882538</ieee_id><sourcerecordid>6882538</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-a8f3f6f6749009f60b6b689fd19a2bf5f2a74f4305d0e13449b09ee726754e3c3</originalsourceid><addsrcrecordid>eNpVkM1KxDAYRSMqOIzdC27yAq1f_pOlzJ_CiBtdD2n7RSttU5qMMG-v4GxcXQ4czuIScsegYgzcw2b9UnFgstLWciXsBSmcsUwa56TWVl_-YyeuyIJZpkphGL8hRUpfACDYryLMgmzX-I19nAYcM42BxilH7LHJcxy7hqZTyjjQEGeajnV7nH1PP3HwOQ6etp3_GGPKXZNuyXXwfcLivEvyvt28rZ7K_evuefW4LztmVC69DSLooI10AC5oqHWtrQstc57XQQXujQxSgGoBmZDS1eAQDddGSRSNWJL7v26HiIdp7gY_nw7nJ8QPLFpPwg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Development of optoelectronic system for subdural hematoma diagnostics</title><source>IEEE Xplore All Conference Series</source><creator>Timchenko, Kristina A. ; Aristov, Alexander A. ; Musorov, Ilya S. ; Evtushenko, Tatyana G.</creator><creatorcontrib>Timchenko, Kristina A. ; Aristov, Alexander A. ; Musorov, Ilya S. ; Evtushenko, Tatyana G.</creatorcontrib><description>In this paper the modern optical techniques for intracranial traumas diagnosis are presented. The main attention is paid to the near-infrared spectroscopy as the most reasonable and effective technique in case of emergency diagnostics. The existing devices based on this operating principle and their limitations are discussed. Moreover, the proposed experimental setup for the diagnosis of hematoma and its localization, several limitations of the device and possible ways of upgrading the system are discussed. The principle of designing a physical phantom of a head with a hematoma, which parameters can be changed by an operator, is also presented.</description><identifier>ISSN: 1815-3712</identifier><identifier>ISBN: 9781479946693</identifier><identifier>ISBN: 1479946699</identifier><identifier>EISBN: 9781479946686</identifier><identifier>EISBN: 1479946680</identifier><identifier>DOI: 10.1109/EDM.2014.6882538</identifier><language>eng</language><publisher>IEEE</publisher><subject>Detectors ; Educational institutions ; hematoma ; infra-red laser ; near-infrared spectroscopy ; Optical detectors ; Optical receivers ; Optical reflection ; Optical scattering ; optical tomography</subject><ispartof>2014 15th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices (EDM), 2014, p.319-322</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6882538$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6882538$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Timchenko, Kristina A.</creatorcontrib><creatorcontrib>Aristov, Alexander A.</creatorcontrib><creatorcontrib>Musorov, Ilya S.</creatorcontrib><creatorcontrib>Evtushenko, Tatyana G.</creatorcontrib><title>Development of optoelectronic system for subdural hematoma diagnostics</title><title>2014 15th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices (EDM)</title><addtitle>EDM</addtitle><description>In this paper the modern optical techniques for intracranial traumas diagnosis are presented. The main attention is paid to the near-infrared spectroscopy as the most reasonable and effective technique in case of emergency diagnostics. The existing devices based on this operating principle and their limitations are discussed. Moreover, the proposed experimental setup for the diagnosis of hematoma and its localization, several limitations of the device and possible ways of upgrading the system are discussed. The principle of designing a physical phantom of a head with a hematoma, which parameters can be changed by an operator, is also presented.</description><subject>Detectors</subject><subject>Educational institutions</subject><subject>hematoma</subject><subject>infra-red laser</subject><subject>near-infrared spectroscopy</subject><subject>Optical detectors</subject><subject>Optical receivers</subject><subject>Optical reflection</subject><subject>Optical scattering</subject><subject>optical tomography</subject><issn>1815-3712</issn><isbn>9781479946693</isbn><isbn>1479946699</isbn><isbn>9781479946686</isbn><isbn>1479946680</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2014</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNpVkM1KxDAYRSMqOIzdC27yAq1f_pOlzJ_CiBtdD2n7RSttU5qMMG-v4GxcXQ4czuIScsegYgzcw2b9UnFgstLWciXsBSmcsUwa56TWVl_-YyeuyIJZpkphGL8hRUpfACDYryLMgmzX-I19nAYcM42BxilH7LHJcxy7hqZTyjjQEGeajnV7nH1PP3HwOQ6etp3_GGPKXZNuyXXwfcLivEvyvt28rZ7K_evuefW4LztmVC69DSLooI10AC5oqHWtrQstc57XQQXujQxSgGoBmZDS1eAQDddGSRSNWJL7v26HiIdp7gY_nw7nJ8QPLFpPwg</recordid><startdate>201406</startdate><enddate>201406</enddate><creator>Timchenko, Kristina A.</creator><creator>Aristov, Alexander A.</creator><creator>Musorov, Ilya S.</creator><creator>Evtushenko, Tatyana G.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201406</creationdate><title>Development of optoelectronic system for subdural hematoma diagnostics</title><author>Timchenko, Kristina A. ; Aristov, Alexander A. ; Musorov, Ilya S. ; Evtushenko, Tatyana G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-a8f3f6f6749009f60b6b689fd19a2bf5f2a74f4305d0e13449b09ee726754e3c3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Detectors</topic><topic>Educational institutions</topic><topic>hematoma</topic><topic>infra-red laser</topic><topic>near-infrared spectroscopy</topic><topic>Optical detectors</topic><topic>Optical receivers</topic><topic>Optical reflection</topic><topic>Optical scattering</topic><topic>optical tomography</topic><toplevel>online_resources</toplevel><creatorcontrib>Timchenko, Kristina A.</creatorcontrib><creatorcontrib>Aristov, Alexander A.</creatorcontrib><creatorcontrib>Musorov, Ilya S.</creatorcontrib><creatorcontrib>Evtushenko, Tatyana G.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Timchenko, Kristina A.</au><au>Aristov, Alexander A.</au><au>Musorov, Ilya S.</au><au>Evtushenko, Tatyana G.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Development of optoelectronic system for subdural hematoma diagnostics</atitle><btitle>2014 15th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices (EDM)</btitle><stitle>EDM</stitle><date>2014-06</date><risdate>2014</risdate><spage>319</spage><epage>322</epage><pages>319-322</pages><issn>1815-3712</issn><isbn>9781479946693</isbn><isbn>1479946699</isbn><eisbn>9781479946686</eisbn><eisbn>1479946680</eisbn><abstract>In this paper the modern optical techniques for intracranial traumas diagnosis are presented. The main attention is paid to the near-infrared spectroscopy as the most reasonable and effective technique in case of emergency diagnostics. The existing devices based on this operating principle and their limitations are discussed. Moreover, the proposed experimental setup for the diagnosis of hematoma and its localization, several limitations of the device and possible ways of upgrading the system are discussed. The principle of designing a physical phantom of a head with a hematoma, which parameters can be changed by an operator, is also presented.</abstract><pub>IEEE</pub><doi>10.1109/EDM.2014.6882538</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1815-3712
ispartof 2014 15th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices (EDM), 2014, p.319-322
issn 1815-3712
language eng
recordid cdi_ieee_primary_6882538
source IEEE Xplore All Conference Series
subjects Detectors
Educational institutions
hematoma
infra-red laser
near-infrared spectroscopy
Optical detectors
Optical receivers
Optical reflection
Optical scattering
optical tomography
title Development of optoelectronic system for subdural hematoma diagnostics
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T15%3A17%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Development%20of%20optoelectronic%20system%20for%20subdural%20hematoma%20diagnostics&rft.btitle=2014%2015th%20International%20Conference%20of%20Young%20Specialists%20on%20Micro/Nanotechnologies%20and%20Electron%20Devices%20(EDM)&rft.au=Timchenko,%20Kristina%20A.&rft.date=2014-06&rft.spage=319&rft.epage=322&rft.pages=319-322&rft.issn=1815-3712&rft.isbn=9781479946693&rft.isbn_list=1479946699&rft_id=info:doi/10.1109/EDM.2014.6882538&rft.eisbn=9781479946686&rft.eisbn_list=1479946680&rft_dat=%3Cieee_CHZPO%3E6882538%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-a8f3f6f6749009f60b6b689fd19a2bf5f2a74f4305d0e13449b09ee726754e3c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6882538&rfr_iscdi=true