Loading…
Automatic detection of left ventricular shape in short axis ultrasound data using a 3D graph search algorithm
Manual tracing is usually required to assess left ventricular (LV) wall boundaries and thicknesses of diseased hearts with echocardiography, a labor-intensive process that limits clinical applicability. The authors present a 3D graph search algorithm that accurately and automatically determines LV e...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 656 |
container_issue | |
container_start_page | 653 |
container_title | |
container_volume | |
creator | VanderLeest, R. McPherson, D. Chandran, K.B. Dove, E.L. |
description | Manual tracing is usually required to assess left ventricular (LV) wall boundaries and thicknesses of diseased hearts with echocardiography, a labor-intensive process that limits clinical applicability. The authors present a 3D graph search algorithm that accurately and automatically determines LV epicardial shape from parasternal short-axis ultrasound (SAX) data. SAX images obtained for 20 subjects (11 normal, 9 abnormal LV morphology) at four levels of the LV were used for this study. Quantitative assessment of the method was performed by linear regression analysis of cross-sectional areas of expert-traced contours and computer-detected contours. An intersection-to-union ratio (IUR) metric was used to assess shape similarity. Linear regression yielded a slope and intercept of 0.96/spl plusmn/0.06 and 3.78/spl plusmn/2.83 cm/sup 2/ respectively with R=0.97, n=80. Shape analysis gave an IUR value of 0.89/spl plusmn/0.03. Normal and diseased results are also discussed. |
doi_str_mv | 10.1109/CIC.1998.731958 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_731958</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>731958</ieee_id><sourcerecordid>731958</sourcerecordid><originalsourceid>FETCH-LOGICAL-i174t-cfd90927031e8ee5b02013f3781ec0e22a64773dbe23d83e1de9cb1432bf61613</originalsourceid><addsrcrecordid>eNotkMtqwzAURAVtoWmadaGr-wNO9bAtaxncVyDQTbsO19K1LfAjSHJp_76BdDUDB4bDMPYg-FYIbp7qfb0VxlRbrYQpqit2x3XFVSE5N9dsxaUus7LI9S3bxOgbLmVxxrpYsXG3pHnE5C04SmSTnyeYWxioTfBNUwreLgMGiD2eCPx0LnNIgD8-wjKkgHFeJgcOE8IS_dQBgnqGLuCph0gYbA84dHPwqR_v2U2LQ6TNf67Z1-vLZ_2eHT7e9vXukHmh85TZ1hlupOZKUEVUnIW5UK3SlSDLSUosc62Va0gqVykSjoxtRK5k05aiFGrNHi-7noiOp-BHDL_HyznqD-0rWXk</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Automatic detection of left ventricular shape in short axis ultrasound data using a 3D graph search algorithm</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>VanderLeest, R. ; McPherson, D. ; Chandran, K.B. ; Dove, E.L.</creator><creatorcontrib>VanderLeest, R. ; McPherson, D. ; Chandran, K.B. ; Dove, E.L.</creatorcontrib><description>Manual tracing is usually required to assess left ventricular (LV) wall boundaries and thicknesses of diseased hearts with echocardiography, a labor-intensive process that limits clinical applicability. The authors present a 3D graph search algorithm that accurately and automatically determines LV epicardial shape from parasternal short-axis ultrasound (SAX) data. SAX images obtained for 20 subjects (11 normal, 9 abnormal LV morphology) at four levels of the LV were used for this study. Quantitative assessment of the method was performed by linear regression analysis of cross-sectional areas of expert-traced contours and computer-detected contours. An intersection-to-union ratio (IUR) metric was used to assess shape similarity. Linear regression yielded a slope and intercept of 0.96/spl plusmn/0.06 and 3.78/spl plusmn/2.83 cm/sup 2/ respectively with R=0.97, n=80. Shape analysis gave an IUR value of 0.89/spl plusmn/0.03. Normal and diseased results are also discussed.</description><identifier>ISSN: 0276-6547</identifier><identifier>ISBN: 0780352009</identifier><identifier>ISBN: 9780780352001</identifier><identifier>DOI: 10.1109/CIC.1998.731958</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical engineering ; Biomedical imaging ; Cities and towns ; Heart ; Image segmentation ; Linear regression ; Shape ; Surface morphology ; Testing ; Ultrasonic imaging</subject><ispartof>Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292), 1998, p.653-656</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/731958$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,777,781,786,787,2052,4036,4037,27906,54901</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/731958$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>VanderLeest, R.</creatorcontrib><creatorcontrib>McPherson, D.</creatorcontrib><creatorcontrib>Chandran, K.B.</creatorcontrib><creatorcontrib>Dove, E.L.</creatorcontrib><title>Automatic detection of left ventricular shape in short axis ultrasound data using a 3D graph search algorithm</title><title>Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292)</title><addtitle>CIC</addtitle><description>Manual tracing is usually required to assess left ventricular (LV) wall boundaries and thicknesses of diseased hearts with echocardiography, a labor-intensive process that limits clinical applicability. The authors present a 3D graph search algorithm that accurately and automatically determines LV epicardial shape from parasternal short-axis ultrasound (SAX) data. SAX images obtained for 20 subjects (11 normal, 9 abnormal LV morphology) at four levels of the LV were used for this study. Quantitative assessment of the method was performed by linear regression analysis of cross-sectional areas of expert-traced contours and computer-detected contours. An intersection-to-union ratio (IUR) metric was used to assess shape similarity. Linear regression yielded a slope and intercept of 0.96/spl plusmn/0.06 and 3.78/spl plusmn/2.83 cm/sup 2/ respectively with R=0.97, n=80. Shape analysis gave an IUR value of 0.89/spl plusmn/0.03. Normal and diseased results are also discussed.</description><subject>Biomedical engineering</subject><subject>Biomedical imaging</subject><subject>Cities and towns</subject><subject>Heart</subject><subject>Image segmentation</subject><subject>Linear regression</subject><subject>Shape</subject><subject>Surface morphology</subject><subject>Testing</subject><subject>Ultrasonic imaging</subject><issn>0276-6547</issn><isbn>0780352009</isbn><isbn>9780780352001</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1998</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkMtqwzAURAVtoWmadaGr-wNO9bAtaxncVyDQTbsO19K1LfAjSHJp_76BdDUDB4bDMPYg-FYIbp7qfb0VxlRbrYQpqit2x3XFVSE5N9dsxaUus7LI9S3bxOgbLmVxxrpYsXG3pHnE5C04SmSTnyeYWxioTfBNUwreLgMGiD2eCPx0LnNIgD8-wjKkgHFeJgcOE8IS_dQBgnqGLuCph0gYbA84dHPwqR_v2U2LQ6TNf67Z1-vLZ_2eHT7e9vXukHmh85TZ1hlupOZKUEVUnIW5UK3SlSDLSUosc62Va0gqVykSjoxtRK5k05aiFGrNHi-7noiOp-BHDL_HyznqD-0rWXk</recordid><startdate>1998</startdate><enddate>1998</enddate><creator>VanderLeest, R.</creator><creator>McPherson, D.</creator><creator>Chandran, K.B.</creator><creator>Dove, E.L.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>1998</creationdate><title>Automatic detection of left ventricular shape in short axis ultrasound data using a 3D graph search algorithm</title><author>VanderLeest, R. ; McPherson, D. ; Chandran, K.B. ; Dove, E.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i174t-cfd90927031e8ee5b02013f3781ec0e22a64773dbe23d83e1de9cb1432bf61613</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Biomedical engineering</topic><topic>Biomedical imaging</topic><topic>Cities and towns</topic><topic>Heart</topic><topic>Image segmentation</topic><topic>Linear regression</topic><topic>Shape</topic><topic>Surface morphology</topic><topic>Testing</topic><topic>Ultrasonic imaging</topic><toplevel>online_resources</toplevel><creatorcontrib>VanderLeest, R.</creatorcontrib><creatorcontrib>McPherson, D.</creatorcontrib><creatorcontrib>Chandran, K.B.</creatorcontrib><creatorcontrib>Dove, E.L.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>VanderLeest, R.</au><au>McPherson, D.</au><au>Chandran, K.B.</au><au>Dove, E.L.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Automatic detection of left ventricular shape in short axis ultrasound data using a 3D graph search algorithm</atitle><btitle>Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292)</btitle><stitle>CIC</stitle><date>1998</date><risdate>1998</risdate><spage>653</spage><epage>656</epage><pages>653-656</pages><issn>0276-6547</issn><isbn>0780352009</isbn><isbn>9780780352001</isbn><abstract>Manual tracing is usually required to assess left ventricular (LV) wall boundaries and thicknesses of diseased hearts with echocardiography, a labor-intensive process that limits clinical applicability. The authors present a 3D graph search algorithm that accurately and automatically determines LV epicardial shape from parasternal short-axis ultrasound (SAX) data. SAX images obtained for 20 subjects (11 normal, 9 abnormal LV morphology) at four levels of the LV were used for this study. Quantitative assessment of the method was performed by linear regression analysis of cross-sectional areas of expert-traced contours and computer-detected contours. An intersection-to-union ratio (IUR) metric was used to assess shape similarity. Linear regression yielded a slope and intercept of 0.96/spl plusmn/0.06 and 3.78/spl plusmn/2.83 cm/sup 2/ respectively with R=0.97, n=80. Shape analysis gave an IUR value of 0.89/spl plusmn/0.03. Normal and diseased results are also discussed.</abstract><pub>IEEE</pub><doi>10.1109/CIC.1998.731958</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0276-6547 |
ispartof | Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292), 1998, p.653-656 |
issn | 0276-6547 |
language | eng |
recordid | cdi_ieee_primary_731958 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Biomedical engineering Biomedical imaging Cities and towns Heart Image segmentation Linear regression Shape Surface morphology Testing Ultrasonic imaging |
title | Automatic detection of left ventricular shape in short axis ultrasound data using a 3D graph search algorithm |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T20%3A51%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Automatic%20detection%20of%20left%20ventricular%20shape%20in%20short%20axis%20ultrasound%20data%20using%20a%203D%20graph%20search%20algorithm&rft.btitle=Computers%20in%20Cardiology%201998.%20Vol.%2025%20(Cat.%20No.98CH36292)&rft.au=VanderLeest,%20R.&rft.date=1998&rft.spage=653&rft.epage=656&rft.pages=653-656&rft.issn=0276-6547&rft.isbn=0780352009&rft.isbn_list=9780780352001&rft_id=info:doi/10.1109/CIC.1998.731958&rft_dat=%3Cieee_6IE%3E731958%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i174t-cfd90927031e8ee5b02013f3781ec0e22a64773dbe23d83e1de9cb1432bf61613%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=731958&rfr_iscdi=true |