Frequency Response of MV Voltage Transformer Under Actual Waveforms

A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms,...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on instrumentation and measurement 2017-06, Vol.66 (6), p.1146-1154
Main Authors: Crotti, Gabriella, Gallo, Daniele, Giordano, Domenico, Landi, Carmine, Luiso, Mario, Modarres, Mohammad
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms, with a fundamental tone at medium voltage level and superimposed harmonics up to 20% and 15 kHz. Combined standard uncertainty in the measurement of the voltage transformer (VT) error is estimated at 200 μV/V for the ratio error and 300 μrad for the phase displacement up to 10 kHz. First applications to the measurement of the frequency response of VTs with different rated primary voltages up to 50 kV are presented.
ISSN:0018-9456
1557-9662
DOI:10.1109/TIM.2017.2652638