Frequency Response of MV Voltage Transformer Under Actual Waveforms
A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms,...
Saved in:
Published in: | IEEE transactions on instrumentation and measurement 2017-06, Vol.66 (6), p.1146-1154 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933 |
---|---|
cites | cdi_FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933 |
container_end_page | 1154 |
container_issue | 6 |
container_start_page | 1146 |
container_title | IEEE transactions on instrumentation and measurement |
container_volume | 66 |
creator | Crotti, Gabriella Gallo, Daniele Giordano, Domenico Landi, Carmine Luiso, Mario Modarres, Mohammad |
description | A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms, with a fundamental tone at medium voltage level and superimposed harmonics up to 20% and 15 kHz. Combined standard uncertainty in the measurement of the voltage transformer (VT) error is estimated at 200 μV/V for the ratio error and 300 μrad for the phase displacement up to 10 kHz. First applications to the measurement of the frequency response of VTs with different rated primary voltages up to 50 kV are presented. |
doi_str_mv | 10.1109/TIM.2017.2652638 |
format | article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_7842615</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7842615</ieee_id><sourcerecordid>2221356427</sourcerecordid><originalsourceid>FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933</originalsourceid><addsrcrecordid>eNo9kN9LAkEQx5coyKz3oJeFns9mf-89iqQJShBqj8u2NxuK3tnuGfjfd6L0MgPD5zszfAh5ZDBgDMqXxXQ-4MDMgGvFtbBXpMeUMkWpNb8mPQBmi1IqfUvuct4AgNHS9MhonPDngHU40g_M-6bOSJtI5yu6arat_0a6SL7OsUk7THRZV10dhvbgt_TT_-Jpnu_JTfTbjA-X3ifL8eti9FbM3ifT0XBWBCFEW3AJUXkduWDcoI062hDACm6rSiNjGGMEAyh50OYrsiCDlb6qKhNBh1KIPnk-792npvs5t27THFLdnXSccyaUltx0FJypkJqcE0a3T-udT0fHwJ1UuU6VO6lyF1Vd5OkcWSPiP26s5Jop8QdO-GSF</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2221356427</pqid></control><display><type>article</type><title>Frequency Response of MV Voltage Transformer Under Actual Waveforms</title><source>IEEE Xplore (Online service)</source><creator>Crotti, Gabriella ; Gallo, Daniele ; Giordano, Domenico ; Landi, Carmine ; Luiso, Mario ; Modarres, Mohammad</creator><creatorcontrib>Crotti, Gabriella ; Gallo, Daniele ; Giordano, Domenico ; Landi, Carmine ; Luiso, Mario ; Modarres, Mohammad</creatorcontrib><description>A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms, with a fundamental tone at medium voltage level and superimposed harmonics up to 20% and 15 kHz. Combined standard uncertainty in the measurement of the voltage transformer (VT) error is estimated at 200 μV/V for the ratio error and 300 μrad for the phase displacement up to 10 kHz. First applications to the measurement of the frequency response of VTs with different rated primary voltages up to 50 kV are presented.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2017.2652638</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Calibration ; Capacitors ; Current measurement ; Electric potential ; Electrical measurement ; Frequency measurement ; Frequency response ; Harmonic analysis ; High voltages ; measurement uncertainty ; medium voltage (MV) ; Phase measurement ; Voltage measurement ; Voltage transformers ; voltage transformers (VTs) ; Waveforms</subject><ispartof>IEEE transactions on instrumentation and measurement, 2017-06, Vol.66 (6), p.1146-1154</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933</citedby><cites>FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7842615$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Crotti, Gabriella</creatorcontrib><creatorcontrib>Gallo, Daniele</creatorcontrib><creatorcontrib>Giordano, Domenico</creatorcontrib><creatorcontrib>Landi, Carmine</creatorcontrib><creatorcontrib>Luiso, Mario</creatorcontrib><creatorcontrib>Modarres, Mohammad</creatorcontrib><title>Frequency Response of MV Voltage Transformer Under Actual Waveforms</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms, with a fundamental tone at medium voltage level and superimposed harmonics up to 20% and 15 kHz. Combined standard uncertainty in the measurement of the voltage transformer (VT) error is estimated at 200 μV/V for the ratio error and 300 μrad for the phase displacement up to 10 kHz. First applications to the measurement of the frequency response of VTs with different rated primary voltages up to 50 kV are presented.</description><subject>Calibration</subject><subject>Capacitors</subject><subject>Current measurement</subject><subject>Electric potential</subject><subject>Electrical measurement</subject><subject>Frequency measurement</subject><subject>Frequency response</subject><subject>Harmonic analysis</subject><subject>High voltages</subject><subject>measurement uncertainty</subject><subject>medium voltage (MV)</subject><subject>Phase measurement</subject><subject>Voltage measurement</subject><subject>Voltage transformers</subject><subject>voltage transformers (VTs)</subject><subject>Waveforms</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNo9kN9LAkEQx5coyKz3oJeFns9mf-89iqQJShBqj8u2NxuK3tnuGfjfd6L0MgPD5zszfAh5ZDBgDMqXxXQ-4MDMgGvFtbBXpMeUMkWpNb8mPQBmi1IqfUvuct4AgNHS9MhonPDngHU40g_M-6bOSJtI5yu6arat_0a6SL7OsUk7THRZV10dhvbgt_TT_-Jpnu_JTfTbjA-X3ifL8eti9FbM3ifT0XBWBCFEW3AJUXkduWDcoI062hDACm6rSiNjGGMEAyh50OYrsiCDlb6qKhNBh1KIPnk-792npvs5t27THFLdnXSccyaUltx0FJypkJqcE0a3T-udT0fHwJ1UuU6VO6lyF1Vd5OkcWSPiP26s5Jop8QdO-GSF</recordid><startdate>20170601</startdate><enddate>20170601</enddate><creator>Crotti, Gabriella</creator><creator>Gallo, Daniele</creator><creator>Giordano, Domenico</creator><creator>Landi, Carmine</creator><creator>Luiso, Mario</creator><creator>Modarres, Mohammad</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20170601</creationdate><title>Frequency Response of MV Voltage Transformer Under Actual Waveforms</title><author>Crotti, Gabriella ; Gallo, Daniele ; Giordano, Domenico ; Landi, Carmine ; Luiso, Mario ; Modarres, Mohammad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Calibration</topic><topic>Capacitors</topic><topic>Current measurement</topic><topic>Electric potential</topic><topic>Electrical measurement</topic><topic>Frequency measurement</topic><topic>Frequency response</topic><topic>Harmonic analysis</topic><topic>High voltages</topic><topic>measurement uncertainty</topic><topic>medium voltage (MV)</topic><topic>Phase measurement</topic><topic>Voltage measurement</topic><topic>Voltage transformers</topic><topic>voltage transformers (VTs)</topic><topic>Waveforms</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Crotti, Gabriella</creatorcontrib><creatorcontrib>Gallo, Daniele</creatorcontrib><creatorcontrib>Giordano, Domenico</creatorcontrib><creatorcontrib>Landi, Carmine</creatorcontrib><creatorcontrib>Luiso, Mario</creatorcontrib><creatorcontrib>Modarres, Mohammad</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005–Present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Crotti, Gabriella</au><au>Gallo, Daniele</au><au>Giordano, Domenico</au><au>Landi, Carmine</au><au>Luiso, Mario</au><au>Modarres, Mohammad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Frequency Response of MV Voltage Transformer Under Actual Waveforms</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>2017-06-01</date><risdate>2017</risdate><volume>66</volume><issue>6</issue><spage>1146</spage><epage>1154</epage><pages>1146-1154</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms, with a fundamental tone at medium voltage level and superimposed harmonics up to 20% and 15 kHz. Combined standard uncertainty in the measurement of the voltage transformer (VT) error is estimated at 200 μV/V for the ratio error and 300 μrad for the phase displacement up to 10 kHz. First applications to the measurement of the frequency response of VTs with different rated primary voltages up to 50 kV are presented.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TIM.2017.2652638</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0018-9456 |
ispartof | IEEE transactions on instrumentation and measurement, 2017-06, Vol.66 (6), p.1146-1154 |
issn | 0018-9456 1557-9662 |
language | eng |
recordid | cdi_ieee_primary_7842615 |
source | IEEE Xplore (Online service) |
subjects | Calibration Capacitors Current measurement Electric potential Electrical measurement Frequency measurement Frequency response Harmonic analysis High voltages measurement uncertainty medium voltage (MV) Phase measurement Voltage measurement Voltage transformers voltage transformers (VTs) Waveforms |
title | Frequency Response of MV Voltage Transformer Under Actual Waveforms |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T09%3A23%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Frequency%20Response%20of%20MV%20Voltage%20Transformer%20Under%20Actual%20Waveforms&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Crotti,%20Gabriella&rft.date=2017-06-01&rft.volume=66&rft.issue=6&rft.spage=1146&rft.epage=1154&rft.pages=1146-1154&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2017.2652638&rft_dat=%3Cproquest_ieee_%3E2221356427%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c333t-240f5a6f23127e8f6f8cc08328dd6e11efff070e42c67bf1c4c84addd7f06c933%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2221356427&rft_id=info:pmid/&rft_ieee_id=7842615&rfr_iscdi=true |