High efficiency separator upgrade: Threading a separator through the eye of a needle

Since 2007, the Nebraska market has been seeing increasing strength requirements. As a result, the Blaine fineness of cement produced by the 1 st generation separator finish mill systems has slowly been increasing to beyond the capability of these units. Finish mill productivity was reduced such tha...

Full description

Saved in:
Bibliographic Details
Main Authors: Edwards, Andy, Paone, Peter, Siberski, S. Douglas
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 13
container_issue
container_start_page 1
container_title
container_volume
creator Edwards, Andy
Paone, Peter
Siberski, S. Douglas
description Since 2007, the Nebraska market has been seeing increasing strength requirements. As a result, the Blaine fineness of cement produced by the 1 st generation separator finish mill systems has slowly been increasing to beyond the capability of these units. Finish mill productivity was reduced such that, where at 3,800 Blaine, the mills could easily out-grind the kilns and satisfy a highly seasonal market, the demands of producing Type I/II cement at 4,700 Blaine to meet market demands reduced the productivity such that finish mill capacity was quickly becoming a bottleneck to cement production. This paper will discuss the project to upgrade the separators at the Nebraska plant from 1 st generation to 3 rd generation in order to regain lost productivity as well as to be able to manufacture Type III cement. It will discuss the challenges of a retrofit project within an existing building along with the challenges of pre-construction while the mills are in operation, short shut-down window, as well as having a restriction of a 16' by 24' opening to fit everything through.
doi_str_mv 10.1109/CITCON.2017.7951852
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_7951852</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7951852</ieee_id><sourcerecordid>7951852</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-aea1e440973e8750b46a219e10bf74ccda413b40b83ea5a6dbb09df4b7e0e8cb3</originalsourceid><addsrcrecordid>eNpNkMFOwzAQRA0SEqX0C3rxDyTsJnZsc0MR0EoVvYRztU42jVFJKyc95O-pRA89zUhPbw4jxBIhRQT3Uq6rcvuVZoAmNU6j1dmdeEINDrR1qO_FLEOtk0vVj2IxDD8AgGB1kdmZqFZh30lu21AH7utJDnyiSOMxyvNpH6nhV1l1kakJ_V7SDR67eDxf3LFjyRPLY3vBPXNz4Gfx0NJh4MU15-L7470qV8lm-7ku3zZJQKPHhJiQlQJncrZGg1cFZegYwbdG1XVDCnOvwNucSVPReA-uaZU3DGxrn8_F8n83MPPuFMMvxWl3PSH_A4fyUfI</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>High efficiency separator upgrade: Threading a separator through the eye of a needle</title><source>IEEE Xplore All Conference Series</source><creator>Edwards, Andy ; Paone, Peter ; Siberski, S. Douglas</creator><creatorcontrib>Edwards, Andy ; Paone, Peter ; Siberski, S. Douglas</creatorcontrib><description>Since 2007, the Nebraska market has been seeing increasing strength requirements. As a result, the Blaine fineness of cement produced by the 1 st generation separator finish mill systems has slowly been increasing to beyond the capability of these units. Finish mill productivity was reduced such that, where at 3,800 Blaine, the mills could easily out-grind the kilns and satisfy a highly seasonal market, the demands of producing Type I/II cement at 4,700 Blaine to meet market demands reduced the productivity such that finish mill capacity was quickly becoming a bottleneck to cement production. This paper will discuss the project to upgrade the separators at the Nebraska plant from 1 st generation to 3 rd generation in order to regain lost productivity as well as to be able to manufacture Type III cement. It will discuss the challenges of a retrofit project within an existing building along with the challenges of pre-construction while the mills are in operation, short shut-down window, as well as having a restriction of a 16' by 24' opening to fit everything through.</description><identifier>EISSN: 2155-9155</identifier><identifier>EISBN: 1509058915</identifier><identifier>EISBN: 9781509058914</identifier><identifier>DOI: 10.1109/CITCON.2017.7951852</identifier><language>eng</language><publisher>IEEE</publisher><subject>cement ; grinding ; separator</subject><ispartof>2017 IEEE-IAS/PCA Cement Industry Technical Conference, 2017, p.1-13</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7951852$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,23930,23931,25140,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/7951852$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Edwards, Andy</creatorcontrib><creatorcontrib>Paone, Peter</creatorcontrib><creatorcontrib>Siberski, S. Douglas</creatorcontrib><title>High efficiency separator upgrade: Threading a separator through the eye of a needle</title><title>2017 IEEE-IAS/PCA Cement Industry Technical Conference</title><addtitle>CITCON</addtitle><description>Since 2007, the Nebraska market has been seeing increasing strength requirements. As a result, the Blaine fineness of cement produced by the 1 st generation separator finish mill systems has slowly been increasing to beyond the capability of these units. Finish mill productivity was reduced such that, where at 3,800 Blaine, the mills could easily out-grind the kilns and satisfy a highly seasonal market, the demands of producing Type I/II cement at 4,700 Blaine to meet market demands reduced the productivity such that finish mill capacity was quickly becoming a bottleneck to cement production. This paper will discuss the project to upgrade the separators at the Nebraska plant from 1 st generation to 3 rd generation in order to regain lost productivity as well as to be able to manufacture Type III cement. It will discuss the challenges of a retrofit project within an existing building along with the challenges of pre-construction while the mills are in operation, short shut-down window, as well as having a restriction of a 16' by 24' opening to fit everything through.</description><subject>cement</subject><subject>grinding</subject><subject>separator</subject><issn>2155-9155</issn><isbn>1509058915</isbn><isbn>9781509058914</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2017</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNpNkMFOwzAQRA0SEqX0C3rxDyTsJnZsc0MR0EoVvYRztU42jVFJKyc95O-pRA89zUhPbw4jxBIhRQT3Uq6rcvuVZoAmNU6j1dmdeEINDrR1qO_FLEOtk0vVj2IxDD8AgGB1kdmZqFZh30lu21AH7utJDnyiSOMxyvNpH6nhV1l1kakJ_V7SDR67eDxf3LFjyRPLY3vBPXNz4Gfx0NJh4MU15-L7470qV8lm-7ku3zZJQKPHhJiQlQJncrZGg1cFZegYwbdG1XVDCnOvwNucSVPReA-uaZU3DGxrn8_F8n83MPPuFMMvxWl3PSH_A4fyUfI</recordid><startdate>201705</startdate><enddate>201705</enddate><creator>Edwards, Andy</creator><creator>Paone, Peter</creator><creator>Siberski, S. Douglas</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201705</creationdate><title>High efficiency separator upgrade: Threading a separator through the eye of a needle</title><author>Edwards, Andy ; Paone, Peter ; Siberski, S. Douglas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-aea1e440973e8750b46a219e10bf74ccda413b40b83ea5a6dbb09df4b7e0e8cb3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2017</creationdate><topic>cement</topic><topic>grinding</topic><topic>separator</topic><toplevel>online_resources</toplevel><creatorcontrib>Edwards, Andy</creatorcontrib><creatorcontrib>Paone, Peter</creatorcontrib><creatorcontrib>Siberski, S. Douglas</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Edwards, Andy</au><au>Paone, Peter</au><au>Siberski, S. Douglas</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>High efficiency separator upgrade: Threading a separator through the eye of a needle</atitle><btitle>2017 IEEE-IAS/PCA Cement Industry Technical Conference</btitle><stitle>CITCON</stitle><date>2017-05</date><risdate>2017</risdate><spage>1</spage><epage>13</epage><pages>1-13</pages><eissn>2155-9155</eissn><eisbn>1509058915</eisbn><eisbn>9781509058914</eisbn><abstract>Since 2007, the Nebraska market has been seeing increasing strength requirements. As a result, the Blaine fineness of cement produced by the 1 st generation separator finish mill systems has slowly been increasing to beyond the capability of these units. Finish mill productivity was reduced such that, where at 3,800 Blaine, the mills could easily out-grind the kilns and satisfy a highly seasonal market, the demands of producing Type I/II cement at 4,700 Blaine to meet market demands reduced the productivity such that finish mill capacity was quickly becoming a bottleneck to cement production. This paper will discuss the project to upgrade the separators at the Nebraska plant from 1 st generation to 3 rd generation in order to regain lost productivity as well as to be able to manufacture Type III cement. It will discuss the challenges of a retrofit project within an existing building along with the challenges of pre-construction while the mills are in operation, short shut-down window, as well as having a restriction of a 16' by 24' opening to fit everything through.</abstract><pub>IEEE</pub><doi>10.1109/CITCON.2017.7951852</doi><tpages>13</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2155-9155
ispartof 2017 IEEE-IAS/PCA Cement Industry Technical Conference, 2017, p.1-13
issn 2155-9155
language eng
recordid cdi_ieee_primary_7951852
source IEEE Xplore All Conference Series
subjects cement
grinding
separator
title High efficiency separator upgrade: Threading a separator through the eye of a needle
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T22%3A56%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=High%20efficiency%20separator%20upgrade:%20Threading%20a%20separator%20through%20the%20eye%20of%20a%20needle&rft.btitle=2017%20IEEE-IAS/PCA%20Cement%20Industry%20Technical%20Conference&rft.au=Edwards,%20Andy&rft.date=2017-05&rft.spage=1&rft.epage=13&rft.pages=1-13&rft.eissn=2155-9155&rft_id=info:doi/10.1109/CITCON.2017.7951852&rft.eisbn=1509058915&rft.eisbn_list=9781509058914&rft_dat=%3Cieee_CHZPO%3E7951852%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-aea1e440973e8750b46a219e10bf74ccda413b40b83ea5a6dbb09df4b7e0e8cb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=7951852&rfr_iscdi=true