Model Enhancements for Real- Time Transient Stability Assessment in Western Interconnection

Power grid is evolving toward a larger, more complex network and power system models are becoming increasingly inadequate for representing real-time operating conditions. Therefore, ensuring consistency between real-time and off-line models is essential for real-time applications which were develope...

Full description

Saved in:
Bibliographic Details
Main Authors: Mahmoudi, Meimanat, Kincic, Slaven, Zhang, Hongming, Tomsovic, Kevin
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 9
container_issue
container_start_page 1
container_title
container_volume
creator Mahmoudi, Meimanat
Kincic, Slaven
Zhang, Hongming
Tomsovic, Kevin
description Power grid is evolving toward a larger, more complex network and power system models are becoming increasingly inadequate for representing real-time operating conditions. Therefore, ensuring consistency between real-time and off-line models is essential for real-time applications which were developed to accommodate the efficient and reliable operation of the grid. In this paper, we describe recent model enhancement efforts implemented to improve the model for Peaks real-time Transient Stability Assessment Tool (TSAT). The model validation process and applied modifications are explained using different case studies and system events in Western Interconnection. The results confirmed the accuracy and trustworthiness of the models in TSAT. Further investigations explored the sensitivity of the operation models to the accuracy of unit baseload flag, unit status, and governor settings. Beside event-based model validation, other accuracy checkpoints for models in TSAT were also discussed. These studies can provide a great insight into insufficiencies which need to be addressed for real-time operation models in power systems.
doi_str_mv 10.1109/TDC.2018.8440558
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_8440558</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8440558</ieee_id><sourcerecordid>8440558</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-effb55d53687f17acc81bb33b4a0901716a25532ef1fb8af358064054dadd60c3</originalsourceid><addsrcrecordid>eNotkE1LxDAYhKMguKy9C17yB1rz0Xz0uNRVF1YErXjwsCTpG4y0qTS57L-3snt6GGYYmEHolpKKUtLcdw9txQjVla5rIoS-QEWjNBVcy0VxdolWjEpSaiH5NSpS-iGEMKlrxdUKfb1MPQx4G79NdDBCzAn7acZvYIYSd2EE3M0mprA4-D0bG4aQj3iTEqT0H8ch4k9IGeaId3GBm2IEl8MUb9CVN0OC4sw1-njcdu1zuX992rWbfRmoErkE760QveBSK0-VcU5Tazm3tSENoYpKw4TgDDz1VhvPhSZymVr3pu8lcXyN7k69AQAOv3MYzXw8nO_gfwZ9VCU</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Model Enhancements for Real- Time Transient Stability Assessment in Western Interconnection</title><source>IEEE Xplore All Conference Series</source><creator>Mahmoudi, Meimanat ; Kincic, Slaven ; Zhang, Hongming ; Tomsovic, Kevin</creator><creatorcontrib>Mahmoudi, Meimanat ; Kincic, Slaven ; Zhang, Hongming ; Tomsovic, Kevin</creatorcontrib><description>Power grid is evolving toward a larger, more complex network and power system models are becoming increasingly inadequate for representing real-time operating conditions. Therefore, ensuring consistency between real-time and off-line models is essential for real-time applications which were developed to accommodate the efficient and reliable operation of the grid. In this paper, we describe recent model enhancement efforts implemented to improve the model for Peaks real-time Transient Stability Assessment Tool (TSAT). The model validation process and applied modifications are explained using different case studies and system events in Western Interconnection. The results confirmed the accuracy and trustworthiness of the models in TSAT. Further investigations explored the sensitivity of the operation models to the accuracy of unit baseload flag, unit status, and governor settings. Beside event-based model validation, other accuracy checkpoints for models in TSAT were also discussed. These studies can provide a great insight into insufficiencies which need to be addressed for real-time operation models in power systems.</description><identifier>EISSN: 2160-8563</identifier><identifier>EISBN: 9781538655832</identifier><identifier>EISBN: 1538655837</identifier><identifier>DOI: 10.1109/TDC.2018.8440558</identifier><language>eng</language><publisher>IEEE</publisher><subject>Model validation ; Real-time transient stability assessment ; Western Interconnection</subject><ispartof>2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&amp;D), 2018, p.1-9</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8440558$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/8440558$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Mahmoudi, Meimanat</creatorcontrib><creatorcontrib>Kincic, Slaven</creatorcontrib><creatorcontrib>Zhang, Hongming</creatorcontrib><creatorcontrib>Tomsovic, Kevin</creatorcontrib><title>Model Enhancements for Real- Time Transient Stability Assessment in Western Interconnection</title><title>2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&amp;D)</title><addtitle>TDC</addtitle><description>Power grid is evolving toward a larger, more complex network and power system models are becoming increasingly inadequate for representing real-time operating conditions. Therefore, ensuring consistency between real-time and off-line models is essential for real-time applications which were developed to accommodate the efficient and reliable operation of the grid. In this paper, we describe recent model enhancement efforts implemented to improve the model for Peaks real-time Transient Stability Assessment Tool (TSAT). The model validation process and applied modifications are explained using different case studies and system events in Western Interconnection. The results confirmed the accuracy and trustworthiness of the models in TSAT. Further investigations explored the sensitivity of the operation models to the accuracy of unit baseload flag, unit status, and governor settings. Beside event-based model validation, other accuracy checkpoints for models in TSAT were also discussed. These studies can provide a great insight into insufficiencies which need to be addressed for real-time operation models in power systems.</description><subject>Model validation</subject><subject>Real-time transient stability assessment</subject><subject>Western Interconnection</subject><issn>2160-8563</issn><isbn>9781538655832</isbn><isbn>1538655837</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2018</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkE1LxDAYhKMguKy9C17yB1rz0Xz0uNRVF1YErXjwsCTpG4y0qTS57L-3snt6GGYYmEHolpKKUtLcdw9txQjVla5rIoS-QEWjNBVcy0VxdolWjEpSaiH5NSpS-iGEMKlrxdUKfb1MPQx4G79NdDBCzAn7acZvYIYSd2EE3M0mprA4-D0bG4aQj3iTEqT0H8ch4k9IGeaId3GBm2IEl8MUb9CVN0OC4sw1-njcdu1zuX992rWbfRmoErkE760QveBSK0-VcU5Tazm3tSENoYpKw4TgDDz1VhvPhSZymVr3pu8lcXyN7k69AQAOv3MYzXw8nO_gfwZ9VCU</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Mahmoudi, Meimanat</creator><creator>Kincic, Slaven</creator><creator>Zhang, Hongming</creator><creator>Tomsovic, Kevin</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201804</creationdate><title>Model Enhancements for Real- Time Transient Stability Assessment in Western Interconnection</title><author>Mahmoudi, Meimanat ; Kincic, Slaven ; Zhang, Hongming ; Tomsovic, Kevin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-effb55d53687f17acc81bb33b4a0901716a25532ef1fb8af358064054dadd60c3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Model validation</topic><topic>Real-time transient stability assessment</topic><topic>Western Interconnection</topic><toplevel>online_resources</toplevel><creatorcontrib>Mahmoudi, Meimanat</creatorcontrib><creatorcontrib>Kincic, Slaven</creatorcontrib><creatorcontrib>Zhang, Hongming</creatorcontrib><creatorcontrib>Tomsovic, Kevin</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Mahmoudi, Meimanat</au><au>Kincic, Slaven</au><au>Zhang, Hongming</au><au>Tomsovic, Kevin</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Model Enhancements for Real- Time Transient Stability Assessment in Western Interconnection</atitle><btitle>2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&amp;D)</btitle><stitle>TDC</stitle><date>2018-04</date><risdate>2018</risdate><spage>1</spage><epage>9</epage><pages>1-9</pages><eissn>2160-8563</eissn><eisbn>9781538655832</eisbn><eisbn>1538655837</eisbn><abstract>Power grid is evolving toward a larger, more complex network and power system models are becoming increasingly inadequate for representing real-time operating conditions. Therefore, ensuring consistency between real-time and off-line models is essential for real-time applications which were developed to accommodate the efficient and reliable operation of the grid. In this paper, we describe recent model enhancement efforts implemented to improve the model for Peaks real-time Transient Stability Assessment Tool (TSAT). The model validation process and applied modifications are explained using different case studies and system events in Western Interconnection. The results confirmed the accuracy and trustworthiness of the models in TSAT. Further investigations explored the sensitivity of the operation models to the accuracy of unit baseload flag, unit status, and governor settings. Beside event-based model validation, other accuracy checkpoints for models in TSAT were also discussed. These studies can provide a great insight into insufficiencies which need to be addressed for real-time operation models in power systems.</abstract><pub>IEEE</pub><doi>10.1109/TDC.2018.8440558</doi><tpages>9</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2160-8563
ispartof 2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D), 2018, p.1-9
issn 2160-8563
language eng
recordid cdi_ieee_primary_8440558
source IEEE Xplore All Conference Series
subjects Model validation
Real-time transient stability assessment
Western Interconnection
title Model Enhancements for Real- Time Transient Stability Assessment in Western Interconnection
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T21%3A45%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Model%20Enhancements%20for%20Real-%20Time%20Transient%20Stability%20Assessment%20in%20Western%20Interconnection&rft.btitle=2018%20IEEE/PES%20Transmission%20and%20Distribution%20Conference%20and%20Exposition%20(T&D)&rft.au=Mahmoudi,%20Meimanat&rft.date=2018-04&rft.spage=1&rft.epage=9&rft.pages=1-9&rft.eissn=2160-8563&rft_id=info:doi/10.1109/TDC.2018.8440558&rft.eisbn=9781538655832&rft.eisbn_list=1538655837&rft_dat=%3Cieee_CHZPO%3E8440558%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i175t-effb55d53687f17acc81bb33b4a0901716a25532ef1fb8af358064054dadd60c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=8440558&rfr_iscdi=true