Loading…

Experimental ultrasound system for real-time synthetic imaging

Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated...

Full description

Saved in:
Bibliographic Details
Main Authors: Jensen, J.A., Holm, O., Jensen, L.J., Bendsen, H., Pedersen, H.M., Salomonsen, K., Hansen, J., Nikolov, S.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1599 vol.2
container_issue
container_start_page 1595
container_title
container_volume 2
creator Jensen, J.A.
Holm, O.
Jensen, L.J.
Bendsen, H.
Pedersen, H.M.
Salomonsen, K.
Hansen, J.
Nikolov, S.
description Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for research purposes. Here flexibility is the prime concern, and the storage of data from all transducer elements over 5 to 10 seconds is needed to perform clinical evaluation of synthetic and 3D imaging. This paper describes a real-time system specifically designed for research purposes. The purpose of the system is to make it possible to acquire multi-channel data in real-time from clinical multi-element ultrasound transducers, and to enable real-time or near real-time processing of the acquired data. The system will be capable of performing the processing for the currently available imaging methods, and will make it possible to perform initial trials in a clinical environment with new imaging modalities for synthetic aperture imaging, 2D and 3D B-mode and velocity imaging. The system can be used with 128 element transducers and can excite 128 channels and receive and sample data from 64 channels simultaneously at 40 MHz with 12 bits precision. Data can be processed in real time using the system's 80 signal processing units or it can be stored directly in RAM. The system has 24 GBytes RAM and can thus store 8 seconds of multi-channel data. It is fully software programmable and its signal processing units can also be reconfigured under software control. The control of the system is done over an Ethernet using C and Matlab. Programs for doing, e.g. B-mode imaging can directly be written in Matlab and executed on the system over the net from any workstation running Matlab. The overall system concept is presented and an example of a 20 lines script for doing phased array B-mode imaging is presented.
doi_str_mv 10.1109/ULTSYM.1999.849300
format conference_proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_849300</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>849300</ieee_id><sourcerecordid>849300</sourcerecordid><originalsourceid>FETCH-LOGICAL-i216t-196e60cc72802cdbe3ed40d110860e5bb3b6292f083169466cf4610d725a2ac83</originalsourceid><addsrcrecordid>eNotj81Kw0AUhQdUsNa-QFd5gcR75382gpT6AxEXtgtXZTK5qSNJWpIp2Lc3UM_mwOFw-A5jS4QCEdzDttx8fr0X6JwrrHQC4IrdgbEglOEcr9kMQWEOiOaWLcbxByZJJY0SM_a4_j3SEDvqk2-zU5sGPx5OfZ2N5zFRlzWHIRvIt3maOlPYp29KMWSx8_vY7-_ZTePbkRb_Pmfb5_Vm9ZqXHy9vq6cyjxx1ytFp0hCC4RZ4qCsSVEuoJ3yrgVRViUpzxxuwArWTWodGaoTacOW5D1bM2fKyG4lod5yA_XDeXd6KP91ISTc</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Experimental ultrasound system for real-time synthetic imaging</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Jensen, J.A. ; Holm, O. ; Jensen, L.J. ; Bendsen, H. ; Pedersen, H.M. ; Salomonsen, K. ; Hansen, J. ; Nikolov, S.</creator><creatorcontrib>Jensen, J.A. ; Holm, O. ; Jensen, L.J. ; Bendsen, H. ; Pedersen, H.M. ; Salomonsen, K. ; Hansen, J. ; Nikolov, S.</creatorcontrib><description>Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for research purposes. Here flexibility is the prime concern, and the storage of data from all transducer elements over 5 to 10 seconds is needed to perform clinical evaluation of synthetic and 3D imaging. This paper describes a real-time system specifically designed for research purposes. The purpose of the system is to make it possible to acquire multi-channel data in real-time from clinical multi-element ultrasound transducers, and to enable real-time or near real-time processing of the acquired data. The system will be capable of performing the processing for the currently available imaging methods, and will make it possible to perform initial trials in a clinical environment with new imaging modalities for synthetic aperture imaging, 2D and 3D B-mode and velocity imaging. The system can be used with 128 element transducers and can excite 128 channels and receive and sample data from 64 channels simultaneously at 40 MHz with 12 bits precision. Data can be processed in real time using the system's 80 signal processing units or it can be stored directly in RAM. The system has 24 GBytes RAM and can thus store 8 seconds of multi-channel data. It is fully software programmable and its signal processing units can also be reconfigured under software control. The control of the system is done over an Ethernet using C and Matlab. Programs for doing, e.g. B-mode imaging can directly be written in Matlab and executed on the system over the net from any workstation running Matlab. The overall system concept is presented and an example of a 20 lines script for doing phased array B-mode imaging is presented.</description><identifier>ISSN: 1051-0117</identifier><identifier>ISBN: 0780357221</identifier><identifier>ISBN: 9780780357228</identifier><identifier>DOI: 10.1109/ULTSYM.1999.849300</identifier><language>eng</language><publisher>IEEE</publisher><subject>Control systems ; Digital signal processing chips ; Focusing ; Image storage ; Performance evaluation ; Phased arrays ; Real time systems ; Signal processing ; Ultrasonic imaging ; Ultrasonic transducers</subject><ispartof>1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027), 1999, Vol.2, p.1595-1599 vol.2</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/849300$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/849300$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Jensen, J.A.</creatorcontrib><creatorcontrib>Holm, O.</creatorcontrib><creatorcontrib>Jensen, L.J.</creatorcontrib><creatorcontrib>Bendsen, H.</creatorcontrib><creatorcontrib>Pedersen, H.M.</creatorcontrib><creatorcontrib>Salomonsen, K.</creatorcontrib><creatorcontrib>Hansen, J.</creatorcontrib><creatorcontrib>Nikolov, S.</creatorcontrib><title>Experimental ultrasound system for real-time synthetic imaging</title><title>1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)</title><addtitle>ULTSYM</addtitle><description>Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for research purposes. Here flexibility is the prime concern, and the storage of data from all transducer elements over 5 to 10 seconds is needed to perform clinical evaluation of synthetic and 3D imaging. This paper describes a real-time system specifically designed for research purposes. The purpose of the system is to make it possible to acquire multi-channel data in real-time from clinical multi-element ultrasound transducers, and to enable real-time or near real-time processing of the acquired data. The system will be capable of performing the processing for the currently available imaging methods, and will make it possible to perform initial trials in a clinical environment with new imaging modalities for synthetic aperture imaging, 2D and 3D B-mode and velocity imaging. The system can be used with 128 element transducers and can excite 128 channels and receive and sample data from 64 channels simultaneously at 40 MHz with 12 bits precision. Data can be processed in real time using the system's 80 signal processing units or it can be stored directly in RAM. The system has 24 GBytes RAM and can thus store 8 seconds of multi-channel data. It is fully software programmable and its signal processing units can also be reconfigured under software control. The control of the system is done over an Ethernet using C and Matlab. Programs for doing, e.g. B-mode imaging can directly be written in Matlab and executed on the system over the net from any workstation running Matlab. The overall system concept is presented and an example of a 20 lines script for doing phased array B-mode imaging is presented.</description><subject>Control systems</subject><subject>Digital signal processing chips</subject><subject>Focusing</subject><subject>Image storage</subject><subject>Performance evaluation</subject><subject>Phased arrays</subject><subject>Real time systems</subject><subject>Signal processing</subject><subject>Ultrasonic imaging</subject><subject>Ultrasonic transducers</subject><issn>1051-0117</issn><isbn>0780357221</isbn><isbn>9780780357228</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1999</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotj81Kw0AUhQdUsNa-QFd5gcR75382gpT6AxEXtgtXZTK5qSNJWpIp2Lc3UM_mwOFw-A5jS4QCEdzDttx8fr0X6JwrrHQC4IrdgbEglOEcr9kMQWEOiOaWLcbxByZJJY0SM_a4_j3SEDvqk2-zU5sGPx5OfZ2N5zFRlzWHIRvIt3maOlPYp29KMWSx8_vY7-_ZTePbkRb_Pmfb5_Vm9ZqXHy9vq6cyjxx1ytFp0hCC4RZ4qCsSVEuoJ3yrgVRViUpzxxuwArWTWodGaoTacOW5D1bM2fKyG4lod5yA_XDeXd6KP91ISTc</recordid><startdate>1999</startdate><enddate>1999</enddate><creator>Jensen, J.A.</creator><creator>Holm, O.</creator><creator>Jensen, L.J.</creator><creator>Bendsen, H.</creator><creator>Pedersen, H.M.</creator><creator>Salomonsen, K.</creator><creator>Hansen, J.</creator><creator>Nikolov, S.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1999</creationdate><title>Experimental ultrasound system for real-time synthetic imaging</title><author>Jensen, J.A. ; Holm, O. ; Jensen, L.J. ; Bendsen, H. ; Pedersen, H.M. ; Salomonsen, K. ; Hansen, J. ; Nikolov, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i216t-196e60cc72802cdbe3ed40d110860e5bb3b6292f083169466cf4610d725a2ac83</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Control systems</topic><topic>Digital signal processing chips</topic><topic>Focusing</topic><topic>Image storage</topic><topic>Performance evaluation</topic><topic>Phased arrays</topic><topic>Real time systems</topic><topic>Signal processing</topic><topic>Ultrasonic imaging</topic><topic>Ultrasonic transducers</topic><toplevel>online_resources</toplevel><creatorcontrib>Jensen, J.A.</creatorcontrib><creatorcontrib>Holm, O.</creatorcontrib><creatorcontrib>Jensen, L.J.</creatorcontrib><creatorcontrib>Bendsen, H.</creatorcontrib><creatorcontrib>Pedersen, H.M.</creatorcontrib><creatorcontrib>Salomonsen, K.</creatorcontrib><creatorcontrib>Hansen, J.</creatorcontrib><creatorcontrib>Nikolov, S.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Jensen, J.A.</au><au>Holm, O.</au><au>Jensen, L.J.</au><au>Bendsen, H.</au><au>Pedersen, H.M.</au><au>Salomonsen, K.</au><au>Hansen, J.</au><au>Nikolov, S.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Experimental ultrasound system for real-time synthetic imaging</atitle><btitle>1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)</btitle><stitle>ULTSYM</stitle><date>1999</date><risdate>1999</risdate><volume>2</volume><spage>1595</spage><epage>1599 vol.2</epage><pages>1595-1599 vol.2</pages><issn>1051-0117</issn><isbn>0780357221</isbn><isbn>9780780357228</isbn><abstract>Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for research purposes. Here flexibility is the prime concern, and the storage of data from all transducer elements over 5 to 10 seconds is needed to perform clinical evaluation of synthetic and 3D imaging. This paper describes a real-time system specifically designed for research purposes. The purpose of the system is to make it possible to acquire multi-channel data in real-time from clinical multi-element ultrasound transducers, and to enable real-time or near real-time processing of the acquired data. The system will be capable of performing the processing for the currently available imaging methods, and will make it possible to perform initial trials in a clinical environment with new imaging modalities for synthetic aperture imaging, 2D and 3D B-mode and velocity imaging. The system can be used with 128 element transducers and can excite 128 channels and receive and sample data from 64 channels simultaneously at 40 MHz with 12 bits precision. Data can be processed in real time using the system's 80 signal processing units or it can be stored directly in RAM. The system has 24 GBytes RAM and can thus store 8 seconds of multi-channel data. It is fully software programmable and its signal processing units can also be reconfigured under software control. The control of the system is done over an Ethernet using C and Matlab. Programs for doing, e.g. B-mode imaging can directly be written in Matlab and executed on the system over the net from any workstation running Matlab. The overall system concept is presented and an example of a 20 lines script for doing phased array B-mode imaging is presented.</abstract><pub>IEEE</pub><doi>10.1109/ULTSYM.1999.849300</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1051-0117
ispartof 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027), 1999, Vol.2, p.1595-1599 vol.2
issn 1051-0117
language eng
recordid cdi_ieee_primary_849300
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Control systems
Digital signal processing chips
Focusing
Image storage
Performance evaluation
Phased arrays
Real time systems
Signal processing
Ultrasonic imaging
Ultrasonic transducers
title Experimental ultrasound system for real-time synthetic imaging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T17%3A53%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Experimental%20ultrasound%20system%20for%20real-time%20synthetic%20imaging&rft.btitle=1999%20IEEE%20Ultrasonics%20Symposium.%20Proceedings.%20International%20Symposium%20(Cat.%20No.99CH37027)&rft.au=Jensen,%20J.A.&rft.date=1999&rft.volume=2&rft.spage=1595&rft.epage=1599%20vol.2&rft.pages=1595-1599%20vol.2&rft.issn=1051-0117&rft.isbn=0780357221&rft.isbn_list=9780780357228&rft_id=info:doi/10.1109/ULTSYM.1999.849300&rft_dat=%3Cieee_6IE%3E849300%3C/ieee_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i216t-196e60cc72802cdbe3ed40d110860e5bb3b6292f083169466cf4610d725a2ac83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=849300&rfr_iscdi=true