Loading…

A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces

This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentia...

Full description

Saved in:
Bibliographic Details
Main Authors: Liu, Zhiduo, Wang, Yijun, Pei, Weihua, Xing, Xiao, Gui, Qiang, Chen, Hongda
Format: Conference Proceeding
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3
cites
container_end_page 814
container_issue
container_start_page 811
container_title
container_volume
creator Liu, Zhiduo
Wang, Yijun
Pei, Weihua
Xing, Xiao
Gui, Qiang
Chen, Hongda
description This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.
doi_str_mv 10.1109/NER.2019.8716951
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_8716951</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8716951</ieee_id><sourcerecordid>8716951</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3</originalsourceid><addsrcrecordid>eNotkL1OwzAURg0SElXJjsTiF3DwjeO_MQ2hrVRR1AJrZSc3EJQmlZMOeXtAdPnOcnSGj5B74DEAt48vxS5OONjYaFBWwhWJrDYghVHaJsCvyQxsapiQMr0l0TB8c85FwlOwZka2GV01n19sh0Pfnsem7-hTmGjRYjmGvkKaheAmWveB7vcfxStbuAErugiu6VjeH0_nEQNdd79buxKHO3JTu3bA6MI5eX8u3vIV22yX6zzbsDIxZmSVB24qJxPkWnkJOuWlSEUtvCgNOm2U06qsa-05OunBJzoFDRpRof7z5uThv9sg4uEUmqML0-FygfgBoeROTw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</title><source>IEEE Xplore All Conference Series</source><creator>Liu, Zhiduo ; Wang, Yijun ; Pei, Weihua ; Xing, Xiao ; Gui, Qiang ; Chen, Hongda</creator><creatorcontrib>Liu, Zhiduo ; Wang, Yijun ; Pei, Weihua ; Xing, Xiao ; Gui, Qiang ; Chen, Hongda</creatorcontrib><description>This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.</description><identifier>EISSN: 1948-3554</identifier><identifier>EISBN: 9781538679210</identifier><identifier>EISBN: 1538679213</identifier><identifier>DOI: 10.1109/NER.2019.8716951</identifier><language>eng</language><publisher>IEEE</publisher><subject>Correlation ; Correlation coefficient ; Electrodes ; Electroencephalography ; Impedance ; Scalp ; Visualization</subject><ispartof>2019 9th International IEEE/EMBS Conference on Neural Engineering (NER), 2019, p.811-814</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8716951$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,27904,54534,54911</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/8716951$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Liu, Zhiduo</creatorcontrib><creatorcontrib>Wang, Yijun</creatorcontrib><creatorcontrib>Pei, Weihua</creatorcontrib><creatorcontrib>Xing, Xiao</creatorcontrib><creatorcontrib>Gui, Qiang</creatorcontrib><creatorcontrib>Chen, Hongda</creatorcontrib><title>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</title><title>2019 9th International IEEE/EMBS Conference on Neural Engineering (NER)</title><addtitle>NER</addtitle><description>This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.</description><subject>Correlation</subject><subject>Correlation coefficient</subject><subject>Electrodes</subject><subject>Electroencephalography</subject><subject>Impedance</subject><subject>Scalp</subject><subject>Visualization</subject><issn>1948-3554</issn><isbn>9781538679210</isbn><isbn>1538679213</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2019</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkL1OwzAURg0SElXJjsTiF3DwjeO_MQ2hrVRR1AJrZSc3EJQmlZMOeXtAdPnOcnSGj5B74DEAt48vxS5OONjYaFBWwhWJrDYghVHaJsCvyQxsapiQMr0l0TB8c85FwlOwZka2GV01n19sh0Pfnsem7-hTmGjRYjmGvkKaheAmWveB7vcfxStbuAErugiu6VjeH0_nEQNdd79buxKHO3JTu3bA6MI5eX8u3vIV22yX6zzbsDIxZmSVB24qJxPkWnkJOuWlSEUtvCgNOm2U06qsa-05OunBJzoFDRpRof7z5uThv9sg4uEUmqML0-FygfgBoeROTw</recordid><startdate>201903</startdate><enddate>201903</enddate><creator>Liu, Zhiduo</creator><creator>Wang, Yijun</creator><creator>Pei, Weihua</creator><creator>Xing, Xiao</creator><creator>Gui, Qiang</creator><creator>Chen, Hongda</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201903</creationdate><title>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</title><author>Liu, Zhiduo ; Wang, Yijun ; Pei, Weihua ; Xing, Xiao ; Gui, Qiang ; Chen, Hongda</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Correlation</topic><topic>Correlation coefficient</topic><topic>Electrodes</topic><topic>Electroencephalography</topic><topic>Impedance</topic><topic>Scalp</topic><topic>Visualization</topic><toplevel>online_resources</toplevel><creatorcontrib>Liu, Zhiduo</creatorcontrib><creatorcontrib>Wang, Yijun</creatorcontrib><creatorcontrib>Pei, Weihua</creatorcontrib><creatorcontrib>Xing, Xiao</creatorcontrib><creatorcontrib>Gui, Qiang</creatorcontrib><creatorcontrib>Chen, Hongda</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Liu, Zhiduo</au><au>Wang, Yijun</au><au>Pei, Weihua</au><au>Xing, Xiao</au><au>Gui, Qiang</au><au>Chen, Hongda</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</atitle><btitle>2019 9th International IEEE/EMBS Conference on Neural Engineering (NER)</btitle><stitle>NER</stitle><date>2019-03</date><risdate>2019</risdate><spage>811</spage><epage>814</epage><pages>811-814</pages><eissn>1948-3554</eissn><eisbn>9781538679210</eisbn><eisbn>1538679213</eisbn><abstract>This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.</abstract><pub>IEEE</pub><doi>10.1109/NER.2019.8716951</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 1948-3554
ispartof 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER), 2019, p.811-814
issn 1948-3554
language eng
recordid cdi_ieee_primary_8716951
source IEEE Xplore All Conference Series
subjects Correlation
Correlation coefficient
Electrodes
Electroencephalography
Impedance
Scalp
Visualization
title A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T15%3A02%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20High-Resolution%20Dry%20Electrode%20Array%20for%20SSVEP-Based%20Brain-Computer%20Interfaces&rft.btitle=2019%209th%20International%20IEEE/EMBS%20Conference%20on%20Neural%20Engineering%20(NER)&rft.au=Liu,%20Zhiduo&rft.date=2019-03&rft.spage=811&rft.epage=814&rft.pages=811-814&rft.eissn=1948-3554&rft_id=info:doi/10.1109/NER.2019.8716951&rft.eisbn=9781538679210&rft.eisbn_list=1538679213&rft_dat=%3Cieee_CHZPO%3E8716951%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=8716951&rfr_iscdi=true