Loading…
A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces
This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentia...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3 |
---|---|
cites | |
container_end_page | 814 |
container_issue | |
container_start_page | 811 |
container_title | |
container_volume | |
creator | Liu, Zhiduo Wang, Yijun Pei, Weihua Xing, Xiao Gui, Qiang Chen, Hongda |
description | This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region. |
doi_str_mv | 10.1109/NER.2019.8716951 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_8716951</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8716951</ieee_id><sourcerecordid>8716951</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3</originalsourceid><addsrcrecordid>eNotkL1OwzAURg0SElXJjsTiF3DwjeO_MQ2hrVRR1AJrZSc3EJQmlZMOeXtAdPnOcnSGj5B74DEAt48vxS5OONjYaFBWwhWJrDYghVHaJsCvyQxsapiQMr0l0TB8c85FwlOwZka2GV01n19sh0Pfnsem7-hTmGjRYjmGvkKaheAmWveB7vcfxStbuAErugiu6VjeH0_nEQNdd79buxKHO3JTu3bA6MI5eX8u3vIV22yX6zzbsDIxZmSVB24qJxPkWnkJOuWlSEUtvCgNOm2U06qsa-05OunBJzoFDRpRof7z5uThv9sg4uEUmqML0-FygfgBoeROTw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</title><source>IEEE Xplore All Conference Series</source><creator>Liu, Zhiduo ; Wang, Yijun ; Pei, Weihua ; Xing, Xiao ; Gui, Qiang ; Chen, Hongda</creator><creatorcontrib>Liu, Zhiduo ; Wang, Yijun ; Pei, Weihua ; Xing, Xiao ; Gui, Qiang ; Chen, Hongda</creatorcontrib><description>This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.</description><identifier>EISSN: 1948-3554</identifier><identifier>EISBN: 9781538679210</identifier><identifier>EISBN: 1538679213</identifier><identifier>DOI: 10.1109/NER.2019.8716951</identifier><language>eng</language><publisher>IEEE</publisher><subject>Correlation ; Correlation coefficient ; Electrodes ; Electroencephalography ; Impedance ; Scalp ; Visualization</subject><ispartof>2019 9th International IEEE/EMBS Conference on Neural Engineering (NER), 2019, p.811-814</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8716951$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,27904,54534,54911</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/8716951$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Liu, Zhiduo</creatorcontrib><creatorcontrib>Wang, Yijun</creatorcontrib><creatorcontrib>Pei, Weihua</creatorcontrib><creatorcontrib>Xing, Xiao</creatorcontrib><creatorcontrib>Gui, Qiang</creatorcontrib><creatorcontrib>Chen, Hongda</creatorcontrib><title>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</title><title>2019 9th International IEEE/EMBS Conference on Neural Engineering (NER)</title><addtitle>NER</addtitle><description>This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.</description><subject>Correlation</subject><subject>Correlation coefficient</subject><subject>Electrodes</subject><subject>Electroencephalography</subject><subject>Impedance</subject><subject>Scalp</subject><subject>Visualization</subject><issn>1948-3554</issn><isbn>9781538679210</isbn><isbn>1538679213</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2019</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkL1OwzAURg0SElXJjsTiF3DwjeO_MQ2hrVRR1AJrZSc3EJQmlZMOeXtAdPnOcnSGj5B74DEAt48vxS5OONjYaFBWwhWJrDYghVHaJsCvyQxsapiQMr0l0TB8c85FwlOwZka2GV01n19sh0Pfnsem7-hTmGjRYjmGvkKaheAmWveB7vcfxStbuAErugiu6VjeH0_nEQNdd79buxKHO3JTu3bA6MI5eX8u3vIV22yX6zzbsDIxZmSVB24qJxPkWnkJOuWlSEUtvCgNOm2U06qsa-05OunBJzoFDRpRof7z5uThv9sg4uEUmqML0-FygfgBoeROTw</recordid><startdate>201903</startdate><enddate>201903</enddate><creator>Liu, Zhiduo</creator><creator>Wang, Yijun</creator><creator>Pei, Weihua</creator><creator>Xing, Xiao</creator><creator>Gui, Qiang</creator><creator>Chen, Hongda</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201903</creationdate><title>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</title><author>Liu, Zhiduo ; Wang, Yijun ; Pei, Weihua ; Xing, Xiao ; Gui, Qiang ; Chen, Hongda</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Correlation</topic><topic>Correlation coefficient</topic><topic>Electrodes</topic><topic>Electroencephalography</topic><topic>Impedance</topic><topic>Scalp</topic><topic>Visualization</topic><toplevel>online_resources</toplevel><creatorcontrib>Liu, Zhiduo</creatorcontrib><creatorcontrib>Wang, Yijun</creatorcontrib><creatorcontrib>Pei, Weihua</creatorcontrib><creatorcontrib>Xing, Xiao</creatorcontrib><creatorcontrib>Gui, Qiang</creatorcontrib><creatorcontrib>Chen, Hongda</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Liu, Zhiduo</au><au>Wang, Yijun</au><au>Pei, Weihua</au><au>Xing, Xiao</au><au>Gui, Qiang</au><au>Chen, Hongda</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces</atitle><btitle>2019 9th International IEEE/EMBS Conference on Neural Engineering (NER)</btitle><stitle>NER</stitle><date>2019-03</date><risdate>2019</risdate><spage>811</spage><epage>814</epage><pages>811-814</pages><eissn>1948-3554</eissn><eisbn>9781538679210</eisbn><eisbn>1538679213</eisbn><abstract>This study aims to design a high-resolution dry electrode array, which can gather multi-channel Electroencephalogram (EEG) signals within a small scalp area. To investigate the independence of the multi-channel signals, the electrode array was applied to recording steady-state visual evoked potentials (SSVEPs) for a brain-computer interface (BCI) system. Currently, there is a certain contact area between the electrode and the scalp when gathering EEG signals. As a result, the acquired signal from one electrode might be a mixture of multiple components, which exhibit independent information, from the whole contact area. Therefore, a dry electrode array, which consists of multiple single-pin electrodes, might be more efficient to collect EEG signals with a spatial resolution at a millimeter scale. This study, therefore, designed a 16-channel high-resolution dry electrode array to record SSVEPs in a four-class BCI system. 16-channel EEG signals were acquired through the electrode array placed at the occipital area from four subjects. Through analyzing the relationship between the number of channels and the BCI performance, this study demonstrated that the electrode array can significantly improve the accuracy of SSVEP detection (12 channels: 88.5%, 1 channel: 80.9%, an average increase of 7.7%), verifying the independence of the SSVEP signals from a small area in the occipital region.</abstract><pub>IEEE</pub><doi>10.1109/NER.2019.8716951</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | EISSN: 1948-3554 |
ispartof | 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER), 2019, p.811-814 |
issn | 1948-3554 |
language | eng |
recordid | cdi_ieee_primary_8716951 |
source | IEEE Xplore All Conference Series |
subjects | Correlation Correlation coefficient Electrodes Electroencephalography Impedance Scalp Visualization |
title | A High-Resolution Dry Electrode Array for SSVEP-Based Brain-Computer Interfaces |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T15%3A02%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20High-Resolution%20Dry%20Electrode%20Array%20for%20SSVEP-Based%20Brain-Computer%20Interfaces&rft.btitle=2019%209th%20International%20IEEE/EMBS%20Conference%20on%20Neural%20Engineering%20(NER)&rft.au=Liu,%20Zhiduo&rft.date=2019-03&rft.spage=811&rft.epage=814&rft.pages=811-814&rft.eissn=1948-3554&rft_id=info:doi/10.1109/NER.2019.8716951&rft.eisbn=9781538679210&rft.eisbn_list=1538679213&rft_dat=%3Cieee_CHZPO%3E8716951%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c288t-db108da52e076b51740c343f3b3c8ea786a76cff7b0ea5b1b2741717ee6e743f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=8716951&rfr_iscdi=true |