Constructive Analysis of Self-inductance Time-varying Self-inductance Coefficient of Stator Winding Synchronous Generator
The calculation formula of the stator-winding self-induction coefficient of salient-pole synchronous generator is deduced based on the motor unified theory. However, there is a certain deficiency, that is, the analysis of the high-order term is abandoned, which produces errors. In order to eliminate...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The calculation formula of the stator-winding self-induction coefficient of salient-pole synchronous generator is deduced based on the motor unified theory. However, there is a certain deficiency, that is, the analysis of the high-order term is abandoned, which produces errors. In order to eliminate the error, the high-order term is analyzed, and the time-varying self-inductance coefficient of the stator winding of the salient-pole generator has a deeper understanding. |
---|---|