Loading…

Study on the Influence of Various Factors on Measurement of CCT for a Controlled Lighting System

A Correlated Color Temperature (CCT) measurement and adjustment system based on a microcontroller, an RGBC sensor and a commercially available programmable lighting section was designed as a building block for developing a more complex intelligent lighting system. Because measurement of the CCT can...

Full description

Saved in:
Bibliographic Details
Main Authors: Haba, Cristian-Gyozo, Breniuc, Liviu, Canale, Laurent, Galatanu, Catalin Daniel
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 5
container_issue
container_start_page 1
container_title
container_volume
creator Haba, Cristian-Gyozo
Breniuc, Liviu
Canale, Laurent
Galatanu, Catalin Daniel
description A Correlated Color Temperature (CCT) measurement and adjustment system based on a microcontroller, an RGBC sensor and a commercially available programmable lighting section was designed as a building block for developing a more complex intelligent lighting system. Because measurement of the CCT can be affected by different errors, in this paper the main sources of error are identified and discussed. CCT calculation relationships based on the RGBC components given by the RGBC sensor, the influence of the illumination level, the influence of the sensor position and the influence of distance between sensor and lighting elements are identified as the main error sources and considerations regarding their decreasing are given.
doi_str_mv 10.1109/IAS.2019.8912313
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_8912313</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8912313</ieee_id><sourcerecordid>8912313</sourcerecordid><originalsourceid>FETCH-LOGICAL-h237t-e4adc090c816891039a2367bf0724d855774d4e415e30f3bce2a519f24515e733</originalsourceid><addsrcrecordid>eNotkE1Lw0AYhFdBsNbeBS_7B1Lf_cpmjyVYLVQ8tIq3uk3ebSJpVnY3h_57U-xpYOZhYIaQBwZzxsA8rRabOQdm5oVhXDBxRWZGF0yJIpdKGLgmE650nmngX7fkLsYfABhDNiHfmzTUJ-p7mhqkq951A_YVUu_opw2tHyJd2ir5EM_MG9o4BDxin85EWW6p84FaWvo-Bd91WNN1e2hS2x_o5hQTHu_JjbNdxNlFp-Rj-bwtX7P1-8uqXKyzhgudMpS2rsBAVbB8XAHCWC5yvXeguawLpbSWtUTJFApwYl8ht4oZx6UaLS3ElDz-97aIuPsN7dGG0-5yiPgDWG9TQg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Study on the Influence of Various Factors on Measurement of CCT for a Controlled Lighting System</title><source>IEEE Xplore All Conference Series</source><creator>Haba, Cristian-Gyozo ; Breniuc, Liviu ; Canale, Laurent ; Galatanu, Catalin Daniel</creator><creatorcontrib>Haba, Cristian-Gyozo ; Breniuc, Liviu ; Canale, Laurent ; Galatanu, Catalin Daniel</creatorcontrib><description>A Correlated Color Temperature (CCT) measurement and adjustment system based on a microcontroller, an RGBC sensor and a commercially available programmable lighting section was designed as a building block for developing a more complex intelligent lighting system. Because measurement of the CCT can be affected by different errors, in this paper the main sources of error are identified and discussed. CCT calculation relationships based on the RGBC components given by the RGBC sensor, the influence of the illumination level, the influence of the sensor position and the influence of distance between sensor and lighting elements are identified as the main error sources and considerations regarding their decreasing are given.</description><identifier>EISSN: 2576-702X</identifier><identifier>EISBN: 9781538645390</identifier><identifier>EISBN: 1538645394</identifier><identifier>DOI: 10.1109/IAS.2019.8912313</identifier><language>eng</language><publisher>IEEE</publisher><subject>Calibration ; Color ; Control systems ; correlated color temperature ; Image color analysis ; LED lamps ; Lighting ; lighting control ; Temperature ; Temperature measurement</subject><ispartof>2019 IEEE Industry Applications Society Annual Meeting, 2019, p.1-5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8912313$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27924,54554,54931</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/8912313$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Haba, Cristian-Gyozo</creatorcontrib><creatorcontrib>Breniuc, Liviu</creatorcontrib><creatorcontrib>Canale, Laurent</creatorcontrib><creatorcontrib>Galatanu, Catalin Daniel</creatorcontrib><title>Study on the Influence of Various Factors on Measurement of CCT for a Controlled Lighting System</title><title>2019 IEEE Industry Applications Society Annual Meeting</title><addtitle>IAS</addtitle><description>A Correlated Color Temperature (CCT) measurement and adjustment system based on a microcontroller, an RGBC sensor and a commercially available programmable lighting section was designed as a building block for developing a more complex intelligent lighting system. Because measurement of the CCT can be affected by different errors, in this paper the main sources of error are identified and discussed. CCT calculation relationships based on the RGBC components given by the RGBC sensor, the influence of the illumination level, the influence of the sensor position and the influence of distance between sensor and lighting elements are identified as the main error sources and considerations regarding their decreasing are given.</description><subject>Calibration</subject><subject>Color</subject><subject>Control systems</subject><subject>correlated color temperature</subject><subject>Image color analysis</subject><subject>LED lamps</subject><subject>Lighting</subject><subject>lighting control</subject><subject>Temperature</subject><subject>Temperature measurement</subject><issn>2576-702X</issn><isbn>9781538645390</isbn><isbn>1538645394</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2019</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkE1Lw0AYhFdBsNbeBS_7B1Lf_cpmjyVYLVQ8tIq3uk3ebSJpVnY3h_57U-xpYOZhYIaQBwZzxsA8rRabOQdm5oVhXDBxRWZGF0yJIpdKGLgmE650nmngX7fkLsYfABhDNiHfmzTUJ-p7mhqkq951A_YVUu_opw2tHyJd2ir5EM_MG9o4BDxin85EWW6p84FaWvo-Bd91WNN1e2hS2x_o5hQTHu_JjbNdxNlFp-Rj-bwtX7P1-8uqXKyzhgudMpS2rsBAVbB8XAHCWC5yvXeguawLpbSWtUTJFApwYl8ht4oZx6UaLS3ElDz-97aIuPsN7dGG0-5yiPgDWG9TQg</recordid><startdate>201909</startdate><enddate>201909</enddate><creator>Haba, Cristian-Gyozo</creator><creator>Breniuc, Liviu</creator><creator>Canale, Laurent</creator><creator>Galatanu, Catalin Daniel</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201909</creationdate><title>Study on the Influence of Various Factors on Measurement of CCT for a Controlled Lighting System</title><author>Haba, Cristian-Gyozo ; Breniuc, Liviu ; Canale, Laurent ; Galatanu, Catalin Daniel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-h237t-e4adc090c816891039a2367bf0724d855774d4e415e30f3bce2a519f24515e733</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Calibration</topic><topic>Color</topic><topic>Control systems</topic><topic>correlated color temperature</topic><topic>Image color analysis</topic><topic>LED lamps</topic><topic>Lighting</topic><topic>lighting control</topic><topic>Temperature</topic><topic>Temperature measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Haba, Cristian-Gyozo</creatorcontrib><creatorcontrib>Breniuc, Liviu</creatorcontrib><creatorcontrib>Canale, Laurent</creatorcontrib><creatorcontrib>Galatanu, Catalin Daniel</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Haba, Cristian-Gyozo</au><au>Breniuc, Liviu</au><au>Canale, Laurent</au><au>Galatanu, Catalin Daniel</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Study on the Influence of Various Factors on Measurement of CCT for a Controlled Lighting System</atitle><btitle>2019 IEEE Industry Applications Society Annual Meeting</btitle><stitle>IAS</stitle><date>2019-09</date><risdate>2019</risdate><spage>1</spage><epage>5</epage><pages>1-5</pages><eissn>2576-702X</eissn><eisbn>9781538645390</eisbn><eisbn>1538645394</eisbn><abstract>A Correlated Color Temperature (CCT) measurement and adjustment system based on a microcontroller, an RGBC sensor and a commercially available programmable lighting section was designed as a building block for developing a more complex intelligent lighting system. Because measurement of the CCT can be affected by different errors, in this paper the main sources of error are identified and discussed. CCT calculation relationships based on the RGBC components given by the RGBC sensor, the influence of the illumination level, the influence of the sensor position and the influence of distance between sensor and lighting elements are identified as the main error sources and considerations regarding their decreasing are given.</abstract><pub>IEEE</pub><doi>10.1109/IAS.2019.8912313</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2576-702X
ispartof 2019 IEEE Industry Applications Society Annual Meeting, 2019, p.1-5
issn 2576-702X
language eng
recordid cdi_ieee_primary_8912313
source IEEE Xplore All Conference Series
subjects Calibration
Color
Control systems
correlated color temperature
Image color analysis
LED lamps
Lighting
lighting control
Temperature
Temperature measurement
title Study on the Influence of Various Factors on Measurement of CCT for a Controlled Lighting System
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T10%3A15%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Study%20on%20the%20Influence%20of%20Various%20Factors%20on%20Measurement%20of%20CCT%20for%20a%20Controlled%20Lighting%20System&rft.btitle=2019%20IEEE%20Industry%20Applications%20Society%20Annual%20Meeting&rft.au=Haba,%20Cristian-Gyozo&rft.date=2019-09&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.eissn=2576-702X&rft_id=info:doi/10.1109/IAS.2019.8912313&rft.eisbn=9781538645390&rft.eisbn_list=1538645394&rft_dat=%3Cieee_CHZPO%3E8912313%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-h237t-e4adc090c816891039a2367bf0724d855774d4e415e30f3bce2a519f24515e733%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=8912313&rfr_iscdi=true