Loading…

Design of Harmonic Tolerant Mock-Up-Load for Distribution System Testbed

To replicate the harmonic behavior of a home load connected to a distribution grid, a Harmonic Tolerant Mock-Up-Load (HT-MuL) is presented in this paper. A comprehensive design methodology of HT-MuL considering various practical constraints such as switching frequency and the output voltage is devel...

Full description

Saved in:
Bibliographic Details
Main Authors: Kumar, Hitesh, Mishra, Santanu K., Rana, Mandeep Singh
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To replicate the harmonic behavior of a home load connected to a distribution grid, a Harmonic Tolerant Mock-Up-Load (HT-MuL) is presented in this paper. A comprehensive design methodology of HT-MuL considering various practical constraints such as switching frequency and the output voltage is developed. The HT-MuL is designed to work as a power sink. It can draw up to 19 th harmonic current from the distribution grid without violating the imposed constraints. A lab-scaled prototype of 110 V, 200 VA is made to validate the performance of HT-MuL with the designed parameters.
ISSN:2329-3748
DOI:10.1109/ECCE44975.2020.9236380