Loading…

Radio Frequency Based Heart Rate Variability Monitoring

Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. In this paper, we present mmHRV, a contact-free HRV monitoring system using commercial millimeter-wave (mmWave) radio. We devise a heartbe...

Full description

Saved in:
Bibliographic Details
Main Authors: Wang, Fengyu, Zeng, Xiaolu, Wu, Chenshu, Wang, Beibei, Ray Liu, K. J.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 8011
container_issue
container_start_page 8007
container_title
container_volume
creator Wang, Fengyu
Zeng, Xiaolu
Wu, Chenshu
Wang, Beibei
Ray Liu, K. J.
description Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. In this paper, we present mmHRV, a contact-free HRV monitoring system using commercial millimeter-wave (mmWave) radio. We devise a heartbeat signal extractor, which can optimize the decomposition of the phase of the channel information modulated by the chest movement, and thus estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the Inter-Beat Intervals (IBIs) can be further derived for evaluating the HRV metrics. Experimental results show that mmHRV can measure the HRV accurately with 3.68ms average error of mean IBI (w.r.t. 99.49% accuracy) based on the experiments over 10 participants.
doi_str_mv 10.1109/ICASSP39728.2021.9413465
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_9413465</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9413465</ieee_id><sourcerecordid>9413465</sourcerecordid><originalsourceid>FETCH-LOGICAL-i203t-c7d7e073bbc8dc2b2e3a4a7da4468d66b79514683143d806b7c6cc42b06758743</originalsourceid><addsrcrecordid>eNotj8tKAzEUhqMgWGufwE1eYMaTy-QkSy3WChWlVXFXcjlKpM5oZlz07TtgV_9l8fP9jHEBtRDgrh_mN5vNs3IobS1BitppobRpTtjMoRVjLdBA05yyiVToKuHg_Zxd9P0XAFjUdsJw7VPu-KLQ7x-1cc9vfU-JL8mXga_9QPzNl-xD3uVhzx-7Ng9dye3nJTv78LueZkedstfF3ct8Wa2e7kesVZUlqKGKmJAAVQjRpiiDJOW1x-S1NjYZE9A1YrRKaJUsjDmaGLUMYLAZCdWUXf3vZiLa_pT87ct-e_ypDn6YR00</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Radio Frequency Based Heart Rate Variability Monitoring</title><source>IEEE Xplore All Conference Series</source><creator>Wang, Fengyu ; Zeng, Xiaolu ; Wu, Chenshu ; Wang, Beibei ; Ray Liu, K. J.</creator><creatorcontrib>Wang, Fengyu ; Zeng, Xiaolu ; Wu, Chenshu ; Wang, Beibei ; Ray Liu, K. J.</creatorcontrib><description>Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. In this paper, we present mmHRV, a contact-free HRV monitoring system using commercial millimeter-wave (mmWave) radio. We devise a heartbeat signal extractor, which can optimize the decomposition of the phase of the channel information modulated by the chest movement, and thus estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the Inter-Beat Intervals (IBIs) can be further derived for evaluating the HRV metrics. Experimental results show that mmHRV can measure the HRV accurately with 3.68ms average error of mean IBI (w.r.t. 99.49% accuracy) based on the experiments over 10 participants.</description><identifier>EISSN: 2379-190X</identifier><identifier>EISBN: 9781728176055</identifier><identifier>EISBN: 1728176050</identifier><identifier>DOI: 10.1109/ICASSP39728.2021.9413465</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atmospheric measurements ; Channel estimation ; Heart Rate Variability (HRV) ; heartbeat estimation ; Millimeter wave measurements ; Millimeter wave radar ; millimeter-wave radio ; Particle measurements ; Sensors ; Signal processing ; wireless sensing</subject><ispartof>ICASSP 2021 - 2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2021, p.8007-8011</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9413465$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9413465$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Wang, Fengyu</creatorcontrib><creatorcontrib>Zeng, Xiaolu</creatorcontrib><creatorcontrib>Wu, Chenshu</creatorcontrib><creatorcontrib>Wang, Beibei</creatorcontrib><creatorcontrib>Ray Liu, K. J.</creatorcontrib><title>Radio Frequency Based Heart Rate Variability Monitoring</title><title>ICASSP 2021 - 2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)</title><addtitle>ICASSP</addtitle><description>Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. In this paper, we present mmHRV, a contact-free HRV monitoring system using commercial millimeter-wave (mmWave) radio. We devise a heartbeat signal extractor, which can optimize the decomposition of the phase of the channel information modulated by the chest movement, and thus estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the Inter-Beat Intervals (IBIs) can be further derived for evaluating the HRV metrics. Experimental results show that mmHRV can measure the HRV accurately with 3.68ms average error of mean IBI (w.r.t. 99.49% accuracy) based on the experiments over 10 participants.</description><subject>Atmospheric measurements</subject><subject>Channel estimation</subject><subject>Heart Rate Variability (HRV)</subject><subject>heartbeat estimation</subject><subject>Millimeter wave measurements</subject><subject>Millimeter wave radar</subject><subject>millimeter-wave radio</subject><subject>Particle measurements</subject><subject>Sensors</subject><subject>Signal processing</subject><subject>wireless sensing</subject><issn>2379-190X</issn><isbn>9781728176055</isbn><isbn>1728176050</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2021</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotj8tKAzEUhqMgWGufwE1eYMaTy-QkSy3WChWlVXFXcjlKpM5oZlz07TtgV_9l8fP9jHEBtRDgrh_mN5vNs3IobS1BitppobRpTtjMoRVjLdBA05yyiVToKuHg_Zxd9P0XAFjUdsJw7VPu-KLQ7x-1cc9vfU-JL8mXga_9QPzNl-xD3uVhzx-7Ng9dye3nJTv78LueZkedstfF3ct8Wa2e7kesVZUlqKGKmJAAVQjRpiiDJOW1x-S1NjYZE9A1YrRKaJUsjDmaGLUMYLAZCdWUXf3vZiLa_pT87ct-e_ypDn6YR00</recordid><startdate>20210606</startdate><enddate>20210606</enddate><creator>Wang, Fengyu</creator><creator>Zeng, Xiaolu</creator><creator>Wu, Chenshu</creator><creator>Wang, Beibei</creator><creator>Ray Liu, K. J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20210606</creationdate><title>Radio Frequency Based Heart Rate Variability Monitoring</title><author>Wang, Fengyu ; Zeng, Xiaolu ; Wu, Chenshu ; Wang, Beibei ; Ray Liu, K. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i203t-c7d7e073bbc8dc2b2e3a4a7da4468d66b79514683143d806b7c6cc42b06758743</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Atmospheric measurements</topic><topic>Channel estimation</topic><topic>Heart Rate Variability (HRV)</topic><topic>heartbeat estimation</topic><topic>Millimeter wave measurements</topic><topic>Millimeter wave radar</topic><topic>millimeter-wave radio</topic><topic>Particle measurements</topic><topic>Sensors</topic><topic>Signal processing</topic><topic>wireless sensing</topic><toplevel>online_resources</toplevel><creatorcontrib>Wang, Fengyu</creatorcontrib><creatorcontrib>Zeng, Xiaolu</creatorcontrib><creatorcontrib>Wu, Chenshu</creatorcontrib><creatorcontrib>Wang, Beibei</creatorcontrib><creatorcontrib>Ray Liu, K. J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Wang, Fengyu</au><au>Zeng, Xiaolu</au><au>Wu, Chenshu</au><au>Wang, Beibei</au><au>Ray Liu, K. J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Radio Frequency Based Heart Rate Variability Monitoring</atitle><btitle>ICASSP 2021 - 2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)</btitle><stitle>ICASSP</stitle><date>2021-06-06</date><risdate>2021</risdate><spage>8007</spage><epage>8011</epage><pages>8007-8011</pages><eissn>2379-190X</eissn><eisbn>9781728176055</eisbn><eisbn>1728176050</eisbn><abstract>Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. In this paper, we present mmHRV, a contact-free HRV monitoring system using commercial millimeter-wave (mmWave) radio. We devise a heartbeat signal extractor, which can optimize the decomposition of the phase of the channel information modulated by the chest movement, and thus estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the Inter-Beat Intervals (IBIs) can be further derived for evaluating the HRV metrics. Experimental results show that mmHRV can measure the HRV accurately with 3.68ms average error of mean IBI (w.r.t. 99.49% accuracy) based on the experiments over 10 participants.</abstract><pub>IEEE</pub><doi>10.1109/ICASSP39728.2021.9413465</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2379-190X
ispartof ICASSP 2021 - 2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2021, p.8007-8011
issn 2379-190X
language eng
recordid cdi_ieee_primary_9413465
source IEEE Xplore All Conference Series
subjects Atmospheric measurements
Channel estimation
Heart Rate Variability (HRV)
heartbeat estimation
Millimeter wave measurements
Millimeter wave radar
millimeter-wave radio
Particle measurements
Sensors
Signal processing
wireless sensing
title Radio Frequency Based Heart Rate Variability Monitoring
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T16%3A15%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Radio%20Frequency%20Based%20Heart%20Rate%20Variability%20Monitoring&rft.btitle=ICASSP%202021%20-%202021%20IEEE%20International%20Conference%20on%20Acoustics,%20Speech%20and%20Signal%20Processing%20(ICASSP)&rft.au=Wang,%20Fengyu&rft.date=2021-06-06&rft.spage=8007&rft.epage=8011&rft.pages=8007-8011&rft.eissn=2379-190X&rft_id=info:doi/10.1109/ICASSP39728.2021.9413465&rft.eisbn=9781728176055&rft.eisbn_list=1728176050&rft_dat=%3Cieee_CHZPO%3E9413465%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i203t-c7d7e073bbc8dc2b2e3a4a7da4468d66b79514683143d806b7c6cc42b06758743%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=9413465&rfr_iscdi=true