Loading…
Considerations on the Harmonic Regime Produced by the Faults Appeared in the Medium Voltage Networks with the Neutral Treated by Extinguishing Coil
The authors present in this paper the results they obtained after the extension of their research and in the field of harmonic regime produced by the grounding of a power line. This type of fault occurs frequently in the case of medium voltage networks, with neutral treated with extinguishing coil....
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 6 |
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Diga, Silvia-Maria Navrapescu, Valentin Diga, Nicolae Bratu, Cristian Mircea, Paul-Mihai |
description | The authors present in this paper the results they obtained after the extension of their research and in the field of harmonic regime produced by the grounding of a power line. This type of fault occurs frequently in the case of medium voltage networks, with neutral treated with extinguishing coil. Thus, they managed to reconstruct the waveforms of currents and voltages during the fault period (grounding). Then, having these calculation elements available, a comparative analysis of similar incidents (earthing) from a 20 kV network with the neutral treated with classic extinguishing coil and modern Trench extinguishing coil, respectively, was made. |
doi_str_mv | 10.1109/ICATE49685.2021.9465063 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_9465063</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9465063</ieee_id><sourcerecordid>9465063</sourcerecordid><originalsourceid>FETCH-LOGICAL-i133t-11ab785138f3d84d2e2ef3f59a8cb1d1921cb77b2a8e8666d8a7ba91cc54b6583</originalsourceid><addsrcrecordid>eNotkE1OwzAQhQ0SElXpCVjgC6T4J3HsZRW1FKkUhArbyo4nrSGJK8dR6Tm4MFHL6o3mzfukNwg9UDKllKjH52K2madKyGzKCKNTlYqMCH6FJiqXNGeSSsIzdY1GTEiZECXYLZp03RchhDPCleAj9Fv4tnMWgo5umLBvcdwDXurQ-NaV-B12rgH8FrztS7DYnM7-Qvd17PDscAAdhrW7xF7Aur7Bn76Oegd4DfHow3eHjy7uzwdr6GPQNd4E0PGCm_9E1-561-0HwYV39R26qXTdweRfx-hjMd8Uy2T1-jSUXiWOch4TSrXJZUa5rLiVqWXAoOJVprQsDbVUMVqaPDdMS5BCCCt1brSiZZmlRmSSj9H9hesAYHsIrtHhtP1_I_8DdFhp-A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Considerations on the Harmonic Regime Produced by the Faults Appeared in the Medium Voltage Networks with the Neutral Treated by Extinguishing Coil</title><source>IEEE Xplore All Conference Series</source><creator>Diga, Silvia-Maria ; Navrapescu, Valentin ; Diga, Nicolae ; Bratu, Cristian ; Mircea, Paul-Mihai</creator><creatorcontrib>Diga, Silvia-Maria ; Navrapescu, Valentin ; Diga, Nicolae ; Bratu, Cristian ; Mircea, Paul-Mihai</creatorcontrib><description>The authors present in this paper the results they obtained after the extension of their research and in the field of harmonic regime produced by the grounding of a power line. This type of fault occurs frequently in the case of medium voltage networks, with neutral treated with extinguishing coil. Thus, they managed to reconstruct the waveforms of currents and voltages during the fault period (grounding). Then, having these calculation elements available, a comparative analysis of similar incidents (earthing) from a 20 kV network with the neutral treated with classic extinguishing coil and modern Trench extinguishing coil, respectively, was made.</description><identifier>EISSN: 2688-0962</identifier><identifier>EISBN: 9781728180359</identifier><identifier>EISBN: 172818035X</identifier><identifier>DOI: 10.1109/ICATE49685.2021.9465063</identifier><language>eng</language><publisher>IEEE</publisher><subject>Conductors ; Grounding ; Medium voltage ; neutral treated with extinguishing coil ; Power distribution ; power distribution faults ; power distribution lines ; power quality ; Power system harmonics ; Resistance ; Total harmonic distortion</subject><ispartof>2021 International Conference on Applied and Theoretical Electricity (ICATE), 2021, p.1-6</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9465063$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9465063$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Diga, Silvia-Maria</creatorcontrib><creatorcontrib>Navrapescu, Valentin</creatorcontrib><creatorcontrib>Diga, Nicolae</creatorcontrib><creatorcontrib>Bratu, Cristian</creatorcontrib><creatorcontrib>Mircea, Paul-Mihai</creatorcontrib><title>Considerations on the Harmonic Regime Produced by the Faults Appeared in the Medium Voltage Networks with the Neutral Treated by Extinguishing Coil</title><title>2021 International Conference on Applied and Theoretical Electricity (ICATE)</title><addtitle>ICATE</addtitle><description>The authors present in this paper the results they obtained after the extension of their research and in the field of harmonic regime produced by the grounding of a power line. This type of fault occurs frequently in the case of medium voltage networks, with neutral treated with extinguishing coil. Thus, they managed to reconstruct the waveforms of currents and voltages during the fault period (grounding). Then, having these calculation elements available, a comparative analysis of similar incidents (earthing) from a 20 kV network with the neutral treated with classic extinguishing coil and modern Trench extinguishing coil, respectively, was made.</description><subject>Conductors</subject><subject>Grounding</subject><subject>Medium voltage</subject><subject>neutral treated with extinguishing coil</subject><subject>Power distribution</subject><subject>power distribution faults</subject><subject>power distribution lines</subject><subject>power quality</subject><subject>Power system harmonics</subject><subject>Resistance</subject><subject>Total harmonic distortion</subject><issn>2688-0962</issn><isbn>9781728180359</isbn><isbn>172818035X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2021</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkE1OwzAQhQ0SElXpCVjgC6T4J3HsZRW1FKkUhArbyo4nrSGJK8dR6Tm4MFHL6o3mzfukNwg9UDKllKjH52K2madKyGzKCKNTlYqMCH6FJiqXNGeSSsIzdY1GTEiZECXYLZp03RchhDPCleAj9Fv4tnMWgo5umLBvcdwDXurQ-NaV-B12rgH8FrztS7DYnM7-Qvd17PDscAAdhrW7xF7Aur7Bn76Oegd4DfHow3eHjy7uzwdr6GPQNd4E0PGCm_9E1-561-0HwYV39R26qXTdweRfx-hjMd8Uy2T1-jSUXiWOch4TSrXJZUa5rLiVqWXAoOJVprQsDbVUMVqaPDdMS5BCCCt1brSiZZmlRmSSj9H9hesAYHsIrtHhtP1_I_8DdFhp-A</recordid><startdate>20210527</startdate><enddate>20210527</enddate><creator>Diga, Silvia-Maria</creator><creator>Navrapescu, Valentin</creator><creator>Diga, Nicolae</creator><creator>Bratu, Cristian</creator><creator>Mircea, Paul-Mihai</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>20210527</creationdate><title>Considerations on the Harmonic Regime Produced by the Faults Appeared in the Medium Voltage Networks with the Neutral Treated by Extinguishing Coil</title><author>Diga, Silvia-Maria ; Navrapescu, Valentin ; Diga, Nicolae ; Bratu, Cristian ; Mircea, Paul-Mihai</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i133t-11ab785138f3d84d2e2ef3f59a8cb1d1921cb77b2a8e8666d8a7ba91cc54b6583</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Conductors</topic><topic>Grounding</topic><topic>Medium voltage</topic><topic>neutral treated with extinguishing coil</topic><topic>Power distribution</topic><topic>power distribution faults</topic><topic>power distribution lines</topic><topic>power quality</topic><topic>Power system harmonics</topic><topic>Resistance</topic><topic>Total harmonic distortion</topic><toplevel>online_resources</toplevel><creatorcontrib>Diga, Silvia-Maria</creatorcontrib><creatorcontrib>Navrapescu, Valentin</creatorcontrib><creatorcontrib>Diga, Nicolae</creatorcontrib><creatorcontrib>Bratu, Cristian</creatorcontrib><creatorcontrib>Mircea, Paul-Mihai</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEL</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Diga, Silvia-Maria</au><au>Navrapescu, Valentin</au><au>Diga, Nicolae</au><au>Bratu, Cristian</au><au>Mircea, Paul-Mihai</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Considerations on the Harmonic Regime Produced by the Faults Appeared in the Medium Voltage Networks with the Neutral Treated by Extinguishing Coil</atitle><btitle>2021 International Conference on Applied and Theoretical Electricity (ICATE)</btitle><stitle>ICATE</stitle><date>2021-05-27</date><risdate>2021</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><eissn>2688-0962</eissn><eisbn>9781728180359</eisbn><eisbn>172818035X</eisbn><abstract>The authors present in this paper the results they obtained after the extension of their research and in the field of harmonic regime produced by the grounding of a power line. This type of fault occurs frequently in the case of medium voltage networks, with neutral treated with extinguishing coil. Thus, they managed to reconstruct the waveforms of currents and voltages during the fault period (grounding). Then, having these calculation elements available, a comparative analysis of similar incidents (earthing) from a 20 kV network with the neutral treated with classic extinguishing coil and modern Trench extinguishing coil, respectively, was made.</abstract><pub>IEEE</pub><doi>10.1109/ICATE49685.2021.9465063</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | EISSN: 2688-0962 |
ispartof | 2021 International Conference on Applied and Theoretical Electricity (ICATE), 2021, p.1-6 |
issn | 2688-0962 |
language | eng |
recordid | cdi_ieee_primary_9465063 |
source | IEEE Xplore All Conference Series |
subjects | Conductors Grounding Medium voltage neutral treated with extinguishing coil Power distribution power distribution faults power distribution lines power quality Power system harmonics Resistance Total harmonic distortion |
title | Considerations on the Harmonic Regime Produced by the Faults Appeared in the Medium Voltage Networks with the Neutral Treated by Extinguishing Coil |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T08%3A21%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Considerations%20on%20the%20Harmonic%20Regime%20Produced%20by%20the%20Faults%20Appeared%20in%20the%20Medium%20Voltage%20Networks%20with%20the%20Neutral%20Treated%20by%20Extinguishing%20Coil&rft.btitle=2021%20International%20Conference%20on%20Applied%20and%20Theoretical%20Electricity%20(ICATE)&rft.au=Diga,%20Silvia-Maria&rft.date=2021-05-27&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.eissn=2688-0962&rft_id=info:doi/10.1109/ICATE49685.2021.9465063&rft.eisbn=9781728180359&rft.eisbn_list=172818035X&rft_dat=%3Cieee_CHZPO%3E9465063%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i133t-11ab785138f3d84d2e2ef3f59a8cb1d1921cb77b2a8e8666d8a7ba91cc54b6583%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=9465063&rfr_iscdi=true |