Loading…

Control Strategy of Grid-Side Converter for Flywheel Energy Storage System under Grid Asymmetrical Faults

Flywheel Energy Storage System (FESS) is a high dynamic response power energy storage. When an asymmetrical fault occurs in the grid-integrated point voltage of FESS, the DC side of the Grid-Side Converter (GSC) using the traditional double-loop control strategy, are contained with even-numbered har...

Full description

Saved in:
Bibliographic Details
Main Authors: Yin, Deqiang, Yao, Liangzhong, Liao, Siyang, Xie, Bo, Xu, Jian, Mao, Beilin
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 452
container_issue
container_start_page 448
container_title
container_volume
creator Yin, Deqiang
Yao, Liangzhong
Liao, Siyang
Xie, Bo
Xu, Jian
Mao, Beilin
description Flywheel Energy Storage System (FESS) is a high dynamic response power energy storage. When an asymmetrical fault occurs in the grid-integrated point voltage of FESS, the DC side of the Grid-Side Converter (GSC) using the traditional double-loop control strategy, are contained with even-numbered harmonics which can seriously affect the quality of output of the GSC. In this paper, a control strategy of the GSC for FESS under asymmetrical faults is proposed. The control strategy can suppress the secondary fluctuations of the output active power and DC bus voltage, and limit the current amplitude of the GSC. Finally, the effectiveness of the control strategy is verified by building a grid-integrated model of the flywheel energy storage GSC on Matlab/Simulink.
doi_str_mv 10.1109/ICET55676.2022.9824424
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_9824424</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9824424</ieee_id><sourcerecordid>9824424</sourcerecordid><originalsourceid>FETCH-LOGICAL-i488-82237627244439514c94ac46a1aabe075a58767f6eb17b4baa710730cac9c2543</originalsourceid><addsrcrecordid>eNotkNtKw0AYhFdBsNY-gSD7Aql73s1lCU1bKHiR3Jc_6Z-6koNstkre3oi9mov5ZmCGkFfO1pyz9O2QbUutjTVrwYRYp04oJdQdeeLGaOU0c-aeLIQ1LjGa60eyGsdPxpgUTDEnF8RnQx_D0NIiBoh4mejQ0F3w56TwZ6Sz-40hYqDNEGjeTj8fiC3d9hhmtIhDgAvSYhojdvTan2fwL0w349R1GIOvoaU5XNs4PpOHBtoRVzddkjLfltk-Ob7vDtnmmHjlXOKEkNYIO-9QMtVc1amCWhngABUyq0E7a2xjsOK2UhWA5cxKVkOd1kIruSQv_7UeEU9fwXcQptPtGPkLZLVYSg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Control Strategy of Grid-Side Converter for Flywheel Energy Storage System under Grid Asymmetrical Faults</title><source>IEEE Xplore All Conference Series</source><creator>Yin, Deqiang ; Yao, Liangzhong ; Liao, Siyang ; Xie, Bo ; Xu, Jian ; Mao, Beilin</creator><creatorcontrib>Yin, Deqiang ; Yao, Liangzhong ; Liao, Siyang ; Xie, Bo ; Xu, Jian ; Mao, Beilin</creatorcontrib><description>Flywheel Energy Storage System (FESS) is a high dynamic response power energy storage. When an asymmetrical fault occurs in the grid-integrated point voltage of FESS, the DC side of the Grid-Side Converter (GSC) using the traditional double-loop control strategy, are contained with even-numbered harmonics which can seriously affect the quality of output of the GSC. In this paper, a control strategy of the GSC for FESS under asymmetrical faults is proposed. The control strategy can suppress the secondary fluctuations of the output active power and DC bus voltage, and limit the current amplitude of the GSC. Finally, the effectiveness of the control strategy is verified by building a grid-integrated model of the flywheel energy storage GSC on Matlab/Simulink.</description><identifier>EISSN: 2768-6515</identifier><identifier>EISBN: 1665485086</identifier><identifier>EISBN: 9781665485081</identifier><identifier>DOI: 10.1109/ICET55676.2022.9824424</identifier><language>eng</language><publisher>IEEE</publisher><subject>asymmetrical faults ; Conferences ; control strategy of the GSC ; current limit ; Fluctuations ; flywheel energy storage system ; Flywheels ; Harmonic analysis ; Mathematical models ; Process control ; Simulation</subject><ispartof>2022 IEEE 5th International Conference on Electronics Technology (ICET), 2022, p.448-452</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9824424$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,23930,23931,25140,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9824424$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Yin, Deqiang</creatorcontrib><creatorcontrib>Yao, Liangzhong</creatorcontrib><creatorcontrib>Liao, Siyang</creatorcontrib><creatorcontrib>Xie, Bo</creatorcontrib><creatorcontrib>Xu, Jian</creatorcontrib><creatorcontrib>Mao, Beilin</creatorcontrib><title>Control Strategy of Grid-Side Converter for Flywheel Energy Storage System under Grid Asymmetrical Faults</title><title>2022 IEEE 5th International Conference on Electronics Technology (ICET)</title><addtitle>ICET</addtitle><description>Flywheel Energy Storage System (FESS) is a high dynamic response power energy storage. When an asymmetrical fault occurs in the grid-integrated point voltage of FESS, the DC side of the Grid-Side Converter (GSC) using the traditional double-loop control strategy, are contained with even-numbered harmonics which can seriously affect the quality of output of the GSC. In this paper, a control strategy of the GSC for FESS under asymmetrical faults is proposed. The control strategy can suppress the secondary fluctuations of the output active power and DC bus voltage, and limit the current amplitude of the GSC. Finally, the effectiveness of the control strategy is verified by building a grid-integrated model of the flywheel energy storage GSC on Matlab/Simulink.</description><subject>asymmetrical faults</subject><subject>Conferences</subject><subject>control strategy of the GSC</subject><subject>current limit</subject><subject>Fluctuations</subject><subject>flywheel energy storage system</subject><subject>Flywheels</subject><subject>Harmonic analysis</subject><subject>Mathematical models</subject><subject>Process control</subject><subject>Simulation</subject><issn>2768-6515</issn><isbn>1665485086</isbn><isbn>9781665485081</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2022</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkNtKw0AYhFdBsNY-gSD7Aql73s1lCU1bKHiR3Jc_6Z-6koNstkre3oi9mov5ZmCGkFfO1pyz9O2QbUutjTVrwYRYp04oJdQdeeLGaOU0c-aeLIQ1LjGa60eyGsdPxpgUTDEnF8RnQx_D0NIiBoh4mejQ0F3w56TwZ6Sz-40hYqDNEGjeTj8fiC3d9hhmtIhDgAvSYhojdvTan2fwL0w349R1GIOvoaU5XNs4PpOHBtoRVzddkjLfltk-Ob7vDtnmmHjlXOKEkNYIO-9QMtVc1amCWhngABUyq0E7a2xjsOK2UhWA5cxKVkOd1kIruSQv_7UeEU9fwXcQptPtGPkLZLVYSg</recordid><startdate>20220513</startdate><enddate>20220513</enddate><creator>Yin, Deqiang</creator><creator>Yao, Liangzhong</creator><creator>Liao, Siyang</creator><creator>Xie, Bo</creator><creator>Xu, Jian</creator><creator>Mao, Beilin</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>20220513</creationdate><title>Control Strategy of Grid-Side Converter for Flywheel Energy Storage System under Grid Asymmetrical Faults</title><author>Yin, Deqiang ; Yao, Liangzhong ; Liao, Siyang ; Xie, Bo ; Xu, Jian ; Mao, Beilin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i488-82237627244439514c94ac46a1aabe075a58767f6eb17b4baa710730cac9c2543</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2022</creationdate><topic>asymmetrical faults</topic><topic>Conferences</topic><topic>control strategy of the GSC</topic><topic>current limit</topic><topic>Fluctuations</topic><topic>flywheel energy storage system</topic><topic>Flywheels</topic><topic>Harmonic analysis</topic><topic>Mathematical models</topic><topic>Process control</topic><topic>Simulation</topic><toplevel>online_resources</toplevel><creatorcontrib>Yin, Deqiang</creatorcontrib><creatorcontrib>Yao, Liangzhong</creatorcontrib><creatorcontrib>Liao, Siyang</creatorcontrib><creatorcontrib>Xie, Bo</creatorcontrib><creatorcontrib>Xu, Jian</creatorcontrib><creatorcontrib>Mao, Beilin</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Yin, Deqiang</au><au>Yao, Liangzhong</au><au>Liao, Siyang</au><au>Xie, Bo</au><au>Xu, Jian</au><au>Mao, Beilin</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Control Strategy of Grid-Side Converter for Flywheel Energy Storage System under Grid Asymmetrical Faults</atitle><btitle>2022 IEEE 5th International Conference on Electronics Technology (ICET)</btitle><stitle>ICET</stitle><date>2022-05-13</date><risdate>2022</risdate><spage>448</spage><epage>452</epage><pages>448-452</pages><eissn>2768-6515</eissn><eisbn>1665485086</eisbn><eisbn>9781665485081</eisbn><abstract>Flywheel Energy Storage System (FESS) is a high dynamic response power energy storage. When an asymmetrical fault occurs in the grid-integrated point voltage of FESS, the DC side of the Grid-Side Converter (GSC) using the traditional double-loop control strategy, are contained with even-numbered harmonics which can seriously affect the quality of output of the GSC. In this paper, a control strategy of the GSC for FESS under asymmetrical faults is proposed. The control strategy can suppress the secondary fluctuations of the output active power and DC bus voltage, and limit the current amplitude of the GSC. Finally, the effectiveness of the control strategy is verified by building a grid-integrated model of the flywheel energy storage GSC on Matlab/Simulink.</abstract><pub>IEEE</pub><doi>10.1109/ICET55676.2022.9824424</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier EISSN: 2768-6515
ispartof 2022 IEEE 5th International Conference on Electronics Technology (ICET), 2022, p.448-452
issn 2768-6515
language eng
recordid cdi_ieee_primary_9824424
source IEEE Xplore All Conference Series
subjects asymmetrical faults
Conferences
control strategy of the GSC
current limit
Fluctuations
flywheel energy storage system
Flywheels
Harmonic analysis
Mathematical models
Process control
Simulation
title Control Strategy of Grid-Side Converter for Flywheel Energy Storage System under Grid Asymmetrical Faults
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T19%3A14%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Control%20Strategy%20of%20Grid-Side%20Converter%20for%20Flywheel%20Energy%20Storage%20System%20under%20Grid%20Asymmetrical%20Faults&rft.btitle=2022%20IEEE%205th%20International%20Conference%20on%20Electronics%20Technology%20(ICET)&rft.au=Yin,%20Deqiang&rft.date=2022-05-13&rft.spage=448&rft.epage=452&rft.pages=448-452&rft.eissn=2768-6515&rft_id=info:doi/10.1109/ICET55676.2022.9824424&rft.eisbn=1665485086&rft.eisbn_list=9781665485081&rft_dat=%3Cieee_CHZPO%3E9824424%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i488-82237627244439514c94ac46a1aabe075a58767f6eb17b4baa710730cac9c2543%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=9824424&rfr_iscdi=true