Loading…

The calibration of digital PTH sensors of the ground observations network of the Italian Air Force Meteorological Service

Meteorological sensors calibration is necessary to ensure the quality of ANS-MET (Air Navigation Services - Meteorological) information. The instruments for the meteorological observations of the ground observation network of the Italian Air Force (ITAF) Met Service need to be calibrated on regular...

Full description

Saved in:
Bibliographic Details
Main Authors: Galliani, Lt. Colonel GArn. Alessandro, Vergari, Lt. Colonel GArn. Stefania, Meli, Tenant GArn. Giuseppe
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Meteorological sensors calibration is necessary to ensure the quality of ANS-MET (Air Navigation Services - Meteorological) information. The instruments for the meteorological observations of the ground observation network of the Italian Air Force (ITAF) Met Service need to be calibrated on regular base. The Technical Centre for Meteorology (CTM), by means of the own calibration laboratory, in compliance with the international regulations, performs the calibration of pressure (P), temperature (T) and humidity (H) digital sensors of meteorological stations.
ISSN:2575-7490
DOI:10.1109/MetroAeroSpace54187.2022.9856023