Loading…
A Plasma Diagnosis Method for a Vacuum Arc Under Curved Contact
Based on the continuous spectrum theory, the plasma parameters of a vacuum arc under curved contact are diagnosed in this study. A colorimetric temperature measurement system composed of a color high-speed camera and bimodal filter is built, which is corrected by a tungsten strip lamp. According to...
Saved in:
Published in: | IEEE transactions on plasma science 2022-09, Vol.50 (9), p.2700-2708 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Based on the continuous spectrum theory, the plasma parameters of a vacuum arc under curved contact are diagnosed in this study. A colorimetric temperature measurement system composed of a color high-speed camera and bimodal filter is built, which is corrected by a tungsten strip lamp. According to the shape characteristics of a vacuum arc under curved contact, a calculation method of radiation intensity using curved space transformation is proposed, which reduces the error caused by the curved contact structure. Finally, the plasma parameter distributions for vacuum arcs under curved contact and butt contact are obtained, and the reason and effect on these distributions are investigated. |
---|---|
ISSN: | 0093-3813 1939-9375 |
DOI: | 10.1109/TPS.2022.3193610 |