Loading…
A Study of Bone Formation Subsequent to Intramedullary Fluid Pressure Fluctuations in Young and Old Rats
Osteoporosis is a major health care concern. In addition to medication, mechanical loading (e.g., exercise) can augment bone mass to alleviate or delay osteoporosis. Reports in the literature indicate that the stimuli initiating bone remodeling with mechanical loading are fluctuations in intramedull...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 4 |
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Haider, Muhammad Luqman Nashawi, Danyah Chen, Ziyu Parvez, Mohammad Salman Sanchez, Amanda S. Le, Teresa Prisby, Rhonda D. Lee, Jeong Bong |
description | Osteoporosis is a major health care concern. In addition to medication, mechanical loading (e.g., exercise) can augment bone mass to alleviate or delay osteoporosis. Reports in the literature indicate that the stimuli initiating bone remodeling with mechanical loading are fluctuations in intramedullary pressure and interstitial fluid flow. Methodologies designed to altered intramedullary pressure and fluid flow involve infection susceptible and external oscillatory equipment. We report preliminary data indicating enhanced bone formation in rat femora by use of polydimethylsiloxane (PDMS) based pressure modulating micropump, which alters intramedullary pressure. These pressure alterations are sensed and recorded via a wireless pressure sensor system for real-time measurement of bone intrameduallry pressure. With only 10 minutes of pressure fluctuation and 7 days of recovery, new bone volume formation in the rats tended (p=0.09) to be higher in femora receiving pressure modulation vs. the contralateral control bone. These results suggest that our system may be efficacious in augmenting bone mass. |
doi_str_mv | 10.1109/SENSORS52175.2022.9967229 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_9967229</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9967229</ieee_id><sourcerecordid>9967229</sourcerecordid><originalsourceid>FETCH-LOGICAL-i203t-a09b088018ad2ca6193f631fb887dfd330d69eaece0b902455450bbddc28ace3</originalsourceid><addsrcrecordid>eNotkMFOAjEYhKuJiYA-gZffB1j8225Le0QCSkJcw3LxRLrbrq5ZurptD7y9qJwmk8k3mQwh9xSnlKJ-KJcvZbEtBaMzMWXI2FRrOWNMX5AxlVLkKpc5XpIRo1Jl-hRck3EIn4gMBVMj8jGHMiZ7hL6Bx947WPXDwcS291CmKrjv5HyE2MPax8EcnE1dZ4YjrLrUWngdXAhpcL-2jumPC9B6eOuTfwfjLRSdha2J4YZcNaYL7vasE7JbLXeL52xTPK0X803WMuQxM6grVAqpMpbVRlLNG8lpUyk1s43lHK3UzrjaYaWR5ULkAqvK2popUzs-IXf_ta1zbv81tIfT2v35FP4Dw6JZqQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A Study of Bone Formation Subsequent to Intramedullary Fluid Pressure Fluctuations in Young and Old Rats</title><source>IEEE Xplore All Conference Series</source><creator>Haider, Muhammad Luqman ; Nashawi, Danyah ; Chen, Ziyu ; Parvez, Mohammad Salman ; Sanchez, Amanda S. ; Le, Teresa ; Prisby, Rhonda D. ; Lee, Jeong Bong</creator><creatorcontrib>Haider, Muhammad Luqman ; Nashawi, Danyah ; Chen, Ziyu ; Parvez, Mohammad Salman ; Sanchez, Amanda S. ; Le, Teresa ; Prisby, Rhonda D. ; Lee, Jeong Bong</creatorcontrib><description>Osteoporosis is a major health care concern. In addition to medication, mechanical loading (e.g., exercise) can augment bone mass to alleviate or delay osteoporosis. Reports in the literature indicate that the stimuli initiating bone remodeling with mechanical loading are fluctuations in intramedullary pressure and interstitial fluid flow. Methodologies designed to altered intramedullary pressure and fluid flow involve infection susceptible and external oscillatory equipment. We report preliminary data indicating enhanced bone formation in rat femora by use of polydimethylsiloxane (PDMS) based pressure modulating micropump, which alters intramedullary pressure. These pressure alterations are sensed and recorded via a wireless pressure sensor system for real-time measurement of bone intrameduallry pressure. With only 10 minutes of pressure fluctuation and 7 days of recovery, new bone volume formation in the rats tended (p=0.09) to be higher in femora receiving pressure modulation vs. the contralateral control bone. These results suggest that our system may be efficacious in augmenting bone mass.</description><identifier>EISSN: 2168-9229</identifier><identifier>EISBN: 1665484640</identifier><identifier>EISBN: 9781665484640</identifier><identifier>DOI: 10.1109/SENSORS52175.2022.9967229</identifier><language>eng</language><publisher>IEEE</publisher><subject>bone ; femur ; Fluctuations ; Fluid flow ; Loading ; Osteoporosis ; pressure modulation ; Pressure sensors ; real-time monitoring ; wireless ; Wireless communication ; Wireless sensor networks</subject><ispartof>2022 IEEE Sensors, 2022, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-4349-9732</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9967229$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,23910,23911,25119,27904,54534,54911</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9967229$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Haider, Muhammad Luqman</creatorcontrib><creatorcontrib>Nashawi, Danyah</creatorcontrib><creatorcontrib>Chen, Ziyu</creatorcontrib><creatorcontrib>Parvez, Mohammad Salman</creatorcontrib><creatorcontrib>Sanchez, Amanda S.</creatorcontrib><creatorcontrib>Le, Teresa</creatorcontrib><creatorcontrib>Prisby, Rhonda D.</creatorcontrib><creatorcontrib>Lee, Jeong Bong</creatorcontrib><title>A Study of Bone Formation Subsequent to Intramedullary Fluid Pressure Fluctuations in Young and Old Rats</title><title>2022 IEEE Sensors</title><addtitle>SENSORS</addtitle><description>Osteoporosis is a major health care concern. In addition to medication, mechanical loading (e.g., exercise) can augment bone mass to alleviate or delay osteoporosis. Reports in the literature indicate that the stimuli initiating bone remodeling with mechanical loading are fluctuations in intramedullary pressure and interstitial fluid flow. Methodologies designed to altered intramedullary pressure and fluid flow involve infection susceptible and external oscillatory equipment. We report preliminary data indicating enhanced bone formation in rat femora by use of polydimethylsiloxane (PDMS) based pressure modulating micropump, which alters intramedullary pressure. These pressure alterations are sensed and recorded via a wireless pressure sensor system for real-time measurement of bone intrameduallry pressure. With only 10 minutes of pressure fluctuation and 7 days of recovery, new bone volume formation in the rats tended (p=0.09) to be higher in femora receiving pressure modulation vs. the contralateral control bone. These results suggest that our system may be efficacious in augmenting bone mass.</description><subject>bone</subject><subject>femur</subject><subject>Fluctuations</subject><subject>Fluid flow</subject><subject>Loading</subject><subject>Osteoporosis</subject><subject>pressure modulation</subject><subject>Pressure sensors</subject><subject>real-time monitoring</subject><subject>wireless</subject><subject>Wireless communication</subject><subject>Wireless sensor networks</subject><issn>2168-9229</issn><isbn>1665484640</isbn><isbn>9781665484640</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2022</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNotkMFOAjEYhKuJiYA-gZffB1j8225Le0QCSkJcw3LxRLrbrq5ZurptD7y9qJwmk8k3mQwh9xSnlKJ-KJcvZbEtBaMzMWXI2FRrOWNMX5AxlVLkKpc5XpIRo1Jl-hRck3EIn4gMBVMj8jGHMiZ7hL6Bx947WPXDwcS291CmKrjv5HyE2MPax8EcnE1dZ4YjrLrUWngdXAhpcL-2jumPC9B6eOuTfwfjLRSdha2J4YZcNaYL7vasE7JbLXeL52xTPK0X803WMuQxM6grVAqpMpbVRlLNG8lpUyk1s43lHK3UzrjaYaWR5ULkAqvK2popUzs-IXf_ta1zbv81tIfT2v35FP4Dw6JZqQ</recordid><startdate>20221030</startdate><enddate>20221030</enddate><creator>Haider, Muhammad Luqman</creator><creator>Nashawi, Danyah</creator><creator>Chen, Ziyu</creator><creator>Parvez, Mohammad Salman</creator><creator>Sanchez, Amanda S.</creator><creator>Le, Teresa</creator><creator>Prisby, Rhonda D.</creator><creator>Lee, Jeong Bong</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><orcidid>https://orcid.org/0000-0002-4349-9732</orcidid></search><sort><creationdate>20221030</creationdate><title>A Study of Bone Formation Subsequent to Intramedullary Fluid Pressure Fluctuations in Young and Old Rats</title><author>Haider, Muhammad Luqman ; Nashawi, Danyah ; Chen, Ziyu ; Parvez, Mohammad Salman ; Sanchez, Amanda S. ; Le, Teresa ; Prisby, Rhonda D. ; Lee, Jeong Bong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i203t-a09b088018ad2ca6193f631fb887dfd330d69eaece0b902455450bbddc28ace3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2022</creationdate><topic>bone</topic><topic>femur</topic><topic>Fluctuations</topic><topic>Fluid flow</topic><topic>Loading</topic><topic>Osteoporosis</topic><topic>pressure modulation</topic><topic>Pressure sensors</topic><topic>real-time monitoring</topic><topic>wireless</topic><topic>Wireless communication</topic><topic>Wireless sensor networks</topic><toplevel>online_resources</toplevel><creatorcontrib>Haider, Muhammad Luqman</creatorcontrib><creatorcontrib>Nashawi, Danyah</creatorcontrib><creatorcontrib>Chen, Ziyu</creatorcontrib><creatorcontrib>Parvez, Mohammad Salman</creatorcontrib><creatorcontrib>Sanchez, Amanda S.</creatorcontrib><creatorcontrib>Le, Teresa</creatorcontrib><creatorcontrib>Prisby, Rhonda D.</creatorcontrib><creatorcontrib>Lee, Jeong Bong</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Haider, Muhammad Luqman</au><au>Nashawi, Danyah</au><au>Chen, Ziyu</au><au>Parvez, Mohammad Salman</au><au>Sanchez, Amanda S.</au><au>Le, Teresa</au><au>Prisby, Rhonda D.</au><au>Lee, Jeong Bong</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A Study of Bone Formation Subsequent to Intramedullary Fluid Pressure Fluctuations in Young and Old Rats</atitle><btitle>2022 IEEE Sensors</btitle><stitle>SENSORS</stitle><date>2022-10-30</date><risdate>2022</risdate><spage>1</spage><epage>4</epage><pages>1-4</pages><eissn>2168-9229</eissn><eisbn>1665484640</eisbn><eisbn>9781665484640</eisbn><abstract>Osteoporosis is a major health care concern. In addition to medication, mechanical loading (e.g., exercise) can augment bone mass to alleviate or delay osteoporosis. Reports in the literature indicate that the stimuli initiating bone remodeling with mechanical loading are fluctuations in intramedullary pressure and interstitial fluid flow. Methodologies designed to altered intramedullary pressure and fluid flow involve infection susceptible and external oscillatory equipment. We report preliminary data indicating enhanced bone formation in rat femora by use of polydimethylsiloxane (PDMS) based pressure modulating micropump, which alters intramedullary pressure. These pressure alterations are sensed and recorded via a wireless pressure sensor system for real-time measurement of bone intrameduallry pressure. With only 10 minutes of pressure fluctuation and 7 days of recovery, new bone volume formation in the rats tended (p=0.09) to be higher in femora receiving pressure modulation vs. the contralateral control bone. These results suggest that our system may be efficacious in augmenting bone mass.</abstract><pub>IEEE</pub><doi>10.1109/SENSORS52175.2022.9967229</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0002-4349-9732</orcidid></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | EISSN: 2168-9229 |
ispartof | 2022 IEEE Sensors, 2022, p.1-4 |
issn | 2168-9229 |
language | eng |
recordid | cdi_ieee_primary_9967229 |
source | IEEE Xplore All Conference Series |
subjects | bone femur Fluctuations Fluid flow Loading Osteoporosis pressure modulation Pressure sensors real-time monitoring wireless Wireless communication Wireless sensor networks |
title | A Study of Bone Formation Subsequent to Intramedullary Fluid Pressure Fluctuations in Young and Old Rats |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T12%3A55%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20Study%20of%20Bone%20Formation%20Subsequent%20to%20Intramedullary%20Fluid%20Pressure%20Fluctuations%20in%20Young%20and%20Old%20Rats&rft.btitle=2022%20IEEE%20Sensors&rft.au=Haider,%20Muhammad%20Luqman&rft.date=2022-10-30&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.eissn=2168-9229&rft_id=info:doi/10.1109/SENSORS52175.2022.9967229&rft.eisbn=1665484640&rft.eisbn_list=9781665484640&rft_dat=%3Cieee_CHZPO%3E9967229%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i203t-a09b088018ad2ca6193f631fb887dfd330d69eaece0b902455450bbddc28ace3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=9967229&rfr_iscdi=true |