Loading…

A flexible data acquisition board for nuclear detectors

For two-dimensional scintillation detectors based on position-sensitive photomultipliers, a new PCI or cPCI unit has been developed. It aims at fast signal and data processing by the usage of advanced technologies like digital signal processors and field-programmable gate arrays. The main features o...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on nuclear science 2002-02, Vol.49 (1), p.318-320
Main Authors: Engels, R., Clemens, U., Rongen, H., Bussmann, N., Kemmerling, G., Reinartz, R., Schelten, J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3
cites cdi_FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3
container_end_page 320
container_issue 1
container_start_page 318
container_title IEEE transactions on nuclear science
container_volume 49
creator Engels, R.
Clemens, U.
Rongen, H.
Bussmann, N.
Kemmerling, G.
Reinartz, R.
Schelten, J.
description For two-dimensional scintillation detectors based on position-sensitive photomultipliers, a new PCI or cPCI unit has been developed. It aims at fast signal and data processing by the usage of advanced technologies like digital signal processors and field-programmable gate arrays. The main features of this design are described in this paper. Digital test measurements were carried out showing that the chosen design complies with the requirements of nuclear pulse processing for such applications.
doi_str_mv 10.1109/TNS.2002.998661
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_998661</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>998661</ieee_id><sourcerecordid>28289296</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3</originalsourceid><addsrcrecordid>eNpdkEtLAzEQgIMoWKtnwdPiwdu2SXbzOpbiC4oerOeQTSawZbtpk13Qf29kiwdhYBjmm2HmQ-iW4AUhWC23bx8LijFdKCU5J2doRhiTJWFCnqMZxkSWqlbqEl2ltMtlzTCbIbEqfAdfbdNB4cxgCmOPY5vaoQ190QQTXeFDLPrRdmBi4WAAO4SYrtGFN12Cm1Oeo8-nx-36pdy8P7-uV5vSVkwMZQNc1cYwaX2DRSN846zHjrkcuPFUEl5XRjgunKgFZ9xIUxuoODApHbXVHD1Mew8xHEdIg963yULXmR7CmDSVVCqqeAbv_4G7MMY-36aVqvK_hMkMLSfIxpBSBK8Psd2b-K0J1r8Wdbaofy3qyWKeuJsmWgD4o0_NH_labWM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>993001158</pqid></control><display><type>article</type><title>A flexible data acquisition board for nuclear detectors</title><source>IEEE Xplore (Online service)</source><creator>Engels, R. ; Clemens, U. ; Rongen, H. ; Bussmann, N. ; Kemmerling, G. ; Reinartz, R. ; Schelten, J.</creator><creatorcontrib>Engels, R. ; Clemens, U. ; Rongen, H. ; Bussmann, N. ; Kemmerling, G. ; Reinartz, R. ; Schelten, J.</creatorcontrib><description>For two-dimensional scintillation detectors based on position-sensitive photomultipliers, a new PCI or cPCI unit has been developed. It aims at fast signal and data processing by the usage of advanced technologies like digital signal processors and field-programmable gate arrays. The main features of this design are described in this paper. Digital test measurements were carried out showing that the chosen design complies with the requirements of nuclear pulse processing for such applications.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2002.998661</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Data acquisition ; Data processing ; Digital signal processors ; Field programmable gate arrays ; Photomultipliers ; Pulse measurements ; Scintillation counters ; Signal processing ; Solid scintillation detectors ; Testing</subject><ispartof>IEEE transactions on nuclear science, 2002-02, Vol.49 (1), p.318-320</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2002</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3</citedby><cites>FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/998661$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,54796</link.rule.ids></links><search><creatorcontrib>Engels, R.</creatorcontrib><creatorcontrib>Clemens, U.</creatorcontrib><creatorcontrib>Rongen, H.</creatorcontrib><creatorcontrib>Bussmann, N.</creatorcontrib><creatorcontrib>Kemmerling, G.</creatorcontrib><creatorcontrib>Reinartz, R.</creatorcontrib><creatorcontrib>Schelten, J.</creatorcontrib><title>A flexible data acquisition board for nuclear detectors</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>For two-dimensional scintillation detectors based on position-sensitive photomultipliers, a new PCI or cPCI unit has been developed. It aims at fast signal and data processing by the usage of advanced technologies like digital signal processors and field-programmable gate arrays. The main features of this design are described in this paper. Digital test measurements were carried out showing that the chosen design complies with the requirements of nuclear pulse processing for such applications.</description><subject>Data acquisition</subject><subject>Data processing</subject><subject>Digital signal processors</subject><subject>Field programmable gate arrays</subject><subject>Photomultipliers</subject><subject>Pulse measurements</subject><subject>Scintillation counters</subject><subject>Signal processing</subject><subject>Solid scintillation detectors</subject><subject>Testing</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNpdkEtLAzEQgIMoWKtnwdPiwdu2SXbzOpbiC4oerOeQTSawZbtpk13Qf29kiwdhYBjmm2HmQ-iW4AUhWC23bx8LijFdKCU5J2doRhiTJWFCnqMZxkSWqlbqEl2ltMtlzTCbIbEqfAdfbdNB4cxgCmOPY5vaoQ190QQTXeFDLPrRdmBi4WAAO4SYrtGFN12Cm1Oeo8-nx-36pdy8P7-uV5vSVkwMZQNc1cYwaX2DRSN846zHjrkcuPFUEl5XRjgunKgFZ9xIUxuoODApHbXVHD1Mew8xHEdIg963yULXmR7CmDSVVCqqeAbv_4G7MMY-36aVqvK_hMkMLSfIxpBSBK8Psd2b-K0J1r8Wdbaofy3qyWKeuJsmWgD4o0_NH_labWM</recordid><startdate>200202</startdate><enddate>200202</enddate><creator>Engels, R.</creator><creator>Clemens, U.</creator><creator>Rongen, H.</creator><creator>Bussmann, N.</creator><creator>Kemmerling, G.</creator><creator>Reinartz, R.</creator><creator>Schelten, J.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QL</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M7N</scope><scope>P64</scope></search><sort><creationdate>200202</creationdate><title>A flexible data acquisition board for nuclear detectors</title><author>Engels, R. ; Clemens, U. ; Rongen, H. ; Bussmann, N. ; Kemmerling, G. ; Reinartz, R. ; Schelten, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Data acquisition</topic><topic>Data processing</topic><topic>Digital signal processors</topic><topic>Field programmable gate arrays</topic><topic>Photomultipliers</topic><topic>Pulse measurements</topic><topic>Scintillation counters</topic><topic>Signal processing</topic><topic>Solid scintillation detectors</topic><topic>Testing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Engels, R.</creatorcontrib><creatorcontrib>Clemens, U.</creatorcontrib><creatorcontrib>Rongen, H.</creatorcontrib><creatorcontrib>Bussmann, N.</creatorcontrib><creatorcontrib>Kemmerling, G.</creatorcontrib><creatorcontrib>Reinartz, R.</creatorcontrib><creatorcontrib>Schelten, J.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE/IET Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Engels, R.</au><au>Clemens, U.</au><au>Rongen, H.</au><au>Bussmann, N.</au><au>Kemmerling, G.</au><au>Reinartz, R.</au><au>Schelten, J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A flexible data acquisition board for nuclear detectors</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>2002-02</date><risdate>2002</risdate><volume>49</volume><issue>1</issue><spage>318</spage><epage>320</epage><pages>318-320</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>For two-dimensional scintillation detectors based on position-sensitive photomultipliers, a new PCI or cPCI unit has been developed. It aims at fast signal and data processing by the usage of advanced technologies like digital signal processors and field-programmable gate arrays. The main features of this design are described in this paper. Digital test measurements were carried out showing that the chosen design complies with the requirements of nuclear pulse processing for such applications.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TNS.2002.998661</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2002-02, Vol.49 (1), p.318-320
issn 0018-9499
1558-1578
language eng
recordid cdi_ieee_primary_998661
source IEEE Xplore (Online service)
subjects Data acquisition
Data processing
Digital signal processors
Field programmable gate arrays
Photomultipliers
Pulse measurements
Scintillation counters
Signal processing
Solid scintillation detectors
Testing
title A flexible data acquisition board for nuclear detectors
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T03%3A26%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20flexible%20data%20acquisition%20board%20for%20nuclear%20detectors&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Engels,%20R.&rft.date=2002-02&rft.volume=49&rft.issue=1&rft.spage=318&rft.epage=320&rft.pages=318-320&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.2002.998661&rft_dat=%3Cproquest_ieee_%3E28289296%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c357t-be694aa58cfb07b7fbdcf0d5dd5d0bf281643a7d67d747656a8a4ae36e588d2c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=993001158&rft_id=info:pmid/&rft_ieee_id=998661&rfr_iscdi=true